Advertisement

Quick Links

S
Package
Cover/Safety
Manual-Service-
PACKAGE-COVER
DOC-Safety-
UL60065
Product Image/s
Specifications
specifications-
BLOCK10-12
Block Diagram
BLOCK-DIAG-
BLOCK10-BLOCK12
ASSOCIATED
BRANDS
TRAYNOR
AMPS
ART PRO
AUDIO
APEX
ELECTRONICS
ORION FX
BLOCK10
Service Manual
Parts List/s
REFlist-M1539
Layouts &
Schematics
Schematic-M1539-
BLOCK10-12_Kb-
Amp
Layout-M1539-
BLOCK10-12_Kb-
Amp
Submit Service Note Request
• Search Again •
SUPPORT
PRODUCT
DOCUMENTS
SERVICE /
REFERENCE
DOCUMENTS
PARTS
SEARCH
Additional
Documents
Notes
Other Request
DEALERS /
DISTRIBUTORS
NORTH
AMERICAN
DEALERS
INTERNATIONAL
DISTRIBUTORS
BECOME A
DEALER /
QuickStart-
BLOCK10_BLOCK12
SERVICE-NOTES
COMPANY
ABOUT
CONTACT
DISTRIBUTED
LINES
CAREERS
PRESS
RELEASES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLOCK 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YORKVILLE BLOCK 10

  • Page 1 BLOCK10 Service Manual Package Parts List/s Additional Cover/Safety Documents REFlist-M1539 Manual-Service- QuickStart- Layouts & PACKAGE-COVER BLOCK10_BLOCK12 DOC-Safety- Schematics UL60065 Notes Schematic-M1539- Product Image/s BLOCK10-12_Kb- SERVICE-NOTES Layout-M1539- BLOCK10-12_Kb- Specifications specifications- BLOCK10-12 Block Diagram BLOCK-DIAG- BLOCK10-BLOCK12 Submit Service Note Request • Other Request •...
  • Page 2 COMPONENTS LIGHTS DISTRIBUTOR SEARCH VTC PRO WARRANTY AUDIO INFORMATION YORKVILLE LEGACY ACCESSORIES PRODUCTS...
  • Page 3 Due to the complex nature of the use of SMT installed components 550 Granite Court 4625 Witmer Industrial Estate in Yorkville equipment, we highly caution all service technicians in Pickering, Ontario Niagara Falls, New York attempting to repair or replace SMT factory installed components.
  • Page 4: Important Safety Instructions

    IMPORTA NT SA FETY INSTRUCTIONS This lightning flash with arrowhead symbol, within an The exclamation point within an equilatereal triangle is intended to alert the user to the presence equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous of important operating and maintenance (servicing) instructions in the literature accompanying voltage”...
  • Page 5: Specifications

    Specifications Cabinet Program Power (watts) Speaker Configuration - LF (Size / Power) BLOCK10: 10-inch/200W BLOCK12: 12-inch/200W Speaker Configuration - HF (Size / Power) 1-inch/50-watts Frequency Response (Hz +/-3dB) 20 - 20k Input Channels 2 x 1/4-inch Channel 1 - inputs Channel 1 - controls Gain, 2 band EQ Channel 2 - inputs...
  • Page 6: Spécifications

    Spécifications Puissance Nominale de l'Enceinte (watts) Configuration de Haut-Parleur - Graves BLOCK10: 10-pouces/200W (Dimension / Puissance) BLOCK12: 12-pouces/200W Configuration de Haut-Parleur - Aigues 1-pouce/50-watts (Dimension / Puissance) Réponse en Fréquence (Hz +/-3dB) 20 - 20k Canaux d'Entrée 2 x 1/4-pouce Canal 1 - entrées Canal 1 - commandes Gain, Égalisateur 2 bandes...
  • Page 7 1/4-INCH Master Volume CHANNEL 3 Gain CLIP CH 2 LINK OUT 1/8-INCH CLIP CH 2 LINK IN 1/4-INCH Inside Cabinet Tweeter Gain CROSSOVER CHANNEL 4 / MONITOR IN 1/4-INCH BLOCK 10 = 10-inch woofer BLOCK 12 = 12-inch woofer BLOCK-DIAG-BLOCK10-BLOCK12-00-1v0...
  • Page 8 M1539 Parts Reference List 1/25/2016 YS # Description YS # Description YS # Description YS # Description YS # Description R120 3746 12V8 27W WIRELEAD SK3CWT3 BULB 7931 270P 50V 5%CAP 0805 SMT NPO 7632 W100 2K32 1% 0805 SMT RES 7859 W125 2K2 5% 0805 SMT RES...
  • Page 9 MC33079D CH-1 L/MONO U6:4 RAD .2in W125 W125 W125 W125 7668 270R 562R 100N 100V 30K0 30K0 W125 0805 0805 1206 0805 3K32 CH1-BASS RAD .2in U2:1 0805 W100 W250 W250 400V 0805 7817 P3:1 0805 1206 1206 MC33079D CH1-GAIN MC33078D B LIN U1:2...
  • Page 10: Block Diagram

    R176 CH-4/MONITOR W100 MC33079D 0805 0805 P1:2 330N 100P 1B LIN R153 7668 U12:1 W100 U4:3 7668 4480 AG = AMP GROUND R149 R150 0805 W100 MC33079D IG = INPUT GROUND W125 W125 SO14 20K0 R177 0805 SG = SIGNAL GROUND 0805 0805 W100...
  • Page 11 DESIGN HISTORY AND INFORMATION CHANGE HISTORY POTENTIOMETERS AND KNOBS DATE VER# DESCRIPTION OF CHANGE POTENTIOMETERS AND KNOBS 11-NOV-2014 FIRST RELEASE FUNCTION POT# KNOB# 03-JUN-2015 8807 Cut traces and tack wire in areas indicated in layout. See PC document for details. CH4-GAIN 4480 10029...
  • Page 12 TO W12 D6 D3 220N 2370 NSL-32SR2 2369 OUTSIDE WIRE 100U 100U MC33078D 4056 4056 100V 3K16 3805 470R R177 2328 Yorkville 330N 2328 R169 100N 100N 100R 2014 100V 100V 100N 100N J109 2371 R199 2N5551 2371 100V 100V...
  • Page 13 PCB ASSEMBLY DOCUMENTATION SPECIAL PRODUCTION NOTES PCB HARDWARE LED SPACERS POWER AMP MODULE MISCELLANEOUS 1. PCBSA: BEND LD1,LD2 USING THE LED BENDING JIG TO THE CORRECT LENGTH 3/16 NYLON SPACER OD 1/8 X ID .063 AND MOUNT TO PCB WITH #8607 SPACER AS SHOWN INTHE PICTURE. HW11 HW10 ICEPOWER 50ASX2...
  • Page 14 DESIGN HISTORY AND INFORMATION CHANGE HISTORY POTENTIOMETERS AND KNOBS DATE VER# DESCRIPTION OF CHANGE POTENTIOMETERS AND KNOBS 11-NOV-2014 FIRST RELEASE FUNCTION POT# KNOB# 03-JUN-2015 8807 Cut traces and tack wire in areas indicated in layout. See PC document for details. CH4-GAIN 4480 10029...
  • Page 15 BLOCK 10 & BLOCK 12 QuickStart 1. Power/Status LED 8. Ch 2 Tone Controls 14. Headphones The power LED displays the status and The Bass and Treble, cover the entire When the Headphone ¼-inch condition of the amplifier. audio spectrum and can help tailor your TRS (stereo) phone jack is used, it sound accordingly.
  • Page 16: Commandes De Tonalité

    BLOCK 10 & BLOCK 12 Guide De Démarrage Rapide 1. DEL Power/Status 8. C. 2 Commandes 14. Casque La DEL d’alimentation indique l’état et le De Tonalité Lorsque la prise ¼ de pouce PBM (stéréo) Les commandes des graves et des aigus, statut de l’amplificateur.
  • Page 17 Yorkville Sound 550 Granite Court Pickering, Ontario Canada L1W 3Y8 www.yorkville.com Auto Attend: (905) 837-8550 Fax: (905) 837-8746...

This manual is also suitable for:

Block 12

Table of Contents