JVC AV-32220/G Service Manual page 18

Table of Contents

Advertisement

AV-32220
INITIAL SETTING VALUE OF SERVICE MENU
1. Adjustment of the SERVICE MENU is made on the basis of the initial setting values; however, the new setting values which set the
screen in its optimum condition may differ from the initial setting.
2. Do not change the initial Setting Values of the Setting (Adjustment) items not listed in "ADJUSTMENT".
" PICTURE MODE
$ The four setting items in the video mode No.8 EXT BRI., No.9 EXT PIC., No.12 EXT TINT and No.13 EXT COLOR are linked to the items in
the TV MODE No.1 BRIGHT, No.2 PICTURE, No.6 TINT and No.7 COLOR, respectively. When the setting items in the TV mode are
adjusted, the values in the setting items in the video mode are revised automatically to the same values in the TV mode. (The initial setting
values given in ( ) are off-set values.)
$ When the four items (No.8, 9, 12 and 13) are adjusted in the video mode, the setting values in each item are revised independently.
Setting (Adjustment) item
No.
1.
BRIGHT
2.
PICTURE
3.
WPS (WHITE PEAK SUPPRESSOR)
4.
TV DETAIL
5.
TV BPF (TV B.P.FILTER)
6.
TINT
7.
COLOR
8.
EXT BRIGHT
9.
EXT PICT.
10.
EXT DETAIL
11.
EXT BPF (EXT B.P.FILTER)
12.
EXT TINT
13.
EXT COLOR
14.
V SIZE
15.
V CENTER
16.
H POSITION
17.
H AFC
18.
BLANKING
19.
RF AGC
20.
PIF VCO
" SOUND MODE
No.
Setting (Adjustment) item
1.
ATTENUATOR
2.
BALANCE
3.
NOISE DET.
4.
IN LEVEL (INPUT LEVEL)
5.
FH MONITOR
6.
STEREO VCO
7.
PILOT CAN. (PILOT CANCELER)
8.
FILTER
9.
LOW SEP. (LOW SEPARATION)
10.
HI SEP. (HIGH SEPARATION)
11.
5FH MON. (5FH MONITOR)
12.
SAP VCO
13.
IN GAIN
14.
FIL.OFFSET
15.
BBE BASS
16.
BBE TRE
18
Variable range
000~127
000~127
000 / 001
000~063
000 / 001
000~127
000~127
±025
±025
000~063
000 / 001
±025
±025
000~063
000~007
000~031
000 / 001
000 / 001
000~063
000~127
Variable range
000~063
000~063
000 / 001
000~063
000 / 001
000~063
000 / 001
000~063
000~063
000~063
000 / 001
000~063
000 / 001
±010
±010
±010
No. 51782
Initial setting value (ALL MODEL)
064
090
001
040
001
074
053
(+001)
(±000)
038
001
(+007)
(+005)
028
000
022
000
000
050
064
Initial setting value (ALL MODEL)
050
032
001
027
000
023
000
030
028
019
000
027
000
±000
-001
-001