  • Page 1 Revision: 01/2022 Copyright © 1997 – 2022 Campbell Scientific CSL I.D - 1196...
  • Page 2 Quotations for repairs can be given on request. It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment, in support of this policy a “Declaration of Hazardous Material and Decontamination”...
  • Page 3 About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American market. Some spellings, weights and measures may reflect this origin. Some useful conversion factors: Area: 1 in (square inch) = 645 mm Mass: 1 oz.
  • Page 4 • Periodically (at least yearly) check electrical ground connections. WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS...
  • Page 5: Table Of Contents

    4.2 Tipping bucket compatibility 5. Specifications 6. Installation 6.1 Siting 6.2 Mounting pole 6.3 CM270 installation 6.4 CS705-to-tipping bucket installation procedure 6.5 Data logger programming 7. Maintenance 8. References Appendix A. MSDS for Campbell Scientific CS705 antifreeze Table of Contents - i...
  • Page 6: Introduction

    1. Introduction The CS705 Snowfall Adapter converts a TE525WS Texas Electronics Rain Gauge to a rain and snow gauge. It consists of an antifreeze reservoir, overflow tube, and catch tube. Snow captured in the catch tube dissolves into the antifreeze raising the overall level. The mixture flows through the overflow tube into the tipping bucket where it is measured.
  • Page 7: Initial Inspection

    The CS705 converts the TE525WS Texas Electronic Rain Gauge, into a year- round precipitation gauge. The CS705 is intended for use only during winter. Like any sensor, optimum performance is obtained by regular site visits. Any antifreeze-based precipitation gauge orifice is susceptible to capping or snow bridging.
  • Page 8: Standard Car Or Rv Antifreeze Is Not Recommended

    4.2 Tipping bucket compatibility The CS705 is equipped with a specially sized cylinder that allows it to nest within the 8-inch orifice of the TE525WS rain gauge. The CS705 cannot be directly used with other Campbell Scientific rain gauges.
  • Page 9: Installation

    Choose a site that is easily accessible throughout the winter. The CS705 Snowfall Adapter and associated rain gauge should be mounted in a relatively level spot that is representative of the surrounding area. The lip of the funnel needs to be horizontal and 76 cm (30 in) above the ground or higher to prevent burial by snow.
  • Page 10: Mounting Pole

    CM300-series poles can be embedded directly into a concrete foundation (FIGURE 6-2 (p. 5)) or used with a pedestal kit. Campbell Scientific offers a j-bolt pedestal kit, a short-leg (23 in) pedestal kit, and a long-leg (39 in) pedestal kit (see FIGURE 6-3 (p.
  • Page 11: Cm270 Installation

    1. Remove the three feet mounted on the bottom of the rain gauge. 2. Remove the side bracket, but keep the screws. 3. Place the side bracket screws into the rain gauge and tighten. This keeps debris out of the threaded holes. CS705 Snowfall Adapter...
  • Page 12 6. Place the S-shaped plate on the spacer and use the bolt to secure it to the bottom plate. Initially finger tighten the bolt and then use a wrench to further tighten. Leave it a bit loose. CS705 Snowfall Adapter...
  • Page 13 FIGURE 6-4. Exploded view of the CM270 Mounting Bracket Kit FIGURE 6-5. Two views of an assembled CM270 CS705 Snowfall Adapter...
  • Page 14 5. Flip the assembly over and tighten the bolt that uses the cylindrical spacer. The bolts securing the levelling springs need to remain loose to allow levelling when the bracket is mounted to the pole or mast. FIGURE 6-6. Mounting CM270 to the rain gauge CS705 Snowfall Adapter...
  • Page 15: Cs705-To-Tipping Bucket Installation Procedure

    4. Adjust the two bolts on the levelling springs until the bubble in the level is inside the bullseye. FIGURE 6-7. Exploded view of CM270 mounting hardware (TE525WS not shown) 6.4 CS705-to-tipping bucket installation procedure Equipment required: User-supplied 0.5-inch (inner diameter) vinyl or Tygon tubing...
  • Page 16 Large band clamp Storage mount FIGURE 6-8. CS705 mounted to pole using the CM270 Mounting Kit 1. Take one of the black bands supplied with the CS705 and stretch over the TE525WS funnel (see FIGURE 6-8 (p. 11) and FIGURE 6-9 (p.
  • Page 17 FIGURE 6-9. CS705 exploded view 2. Insert the CS705 antifreeze reservoir into the rain gauge funnel. CAUTION: Wear safety glasses during handling and pouring of antifreeze. 3. Fill the reservoir with PGE antifreeze until a small amount flows out the overflow tube. The reservoir holds ≈2.5 gallons.
  • Page 18: Data Logger Programming

    8. Fasten the catch tube of the CS705 to the mounting pole using the band clamps and storage mount (see FIGURE 6-8 (p. 11)). 9. Place the pail below the rain gauge. 10. Connect one end of the tubing onto the funnel and place the other end of tubing in the pail.
  • Page 19: References

    However, local laws, regulations, or policies may require the collection and safe disposal of all antifreeze used in the CS705. The #14087 funnel should be installed with the CM270 mounting kit and attached to user-supplied 0.5-inch (I.D.) vinyl or Tygon tubing that drains into a user-supplied pail.
  • Page 20: Appendix A. Msds For Campbell Scientific Cs705 Antifreeze

    EMERGENCY TELEPHONE NUMBER: (412) 981-3771 CHEMTREC EMERGENCY TELEPHONE NUMBER: (800) 424-9300 ADDRESS (NUMBER, STREET, CITY, STATE, ZIP): 2797 Freedland Rd. Hermitage, Pa. 16148 CHEMICAL NAME AND SYNONYMS: CAMPBELL SCIENTIFIC CS705 ANTIFREEZE TRADE NAME AND SYNONYMS: Same as above. CHEMICAL FAMILY: Solvent blend. FORMULA: Mixture...
  • Page 21 Date Printed: 09-26-1997          Page 2 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 4 — Section III – Physical Data BOILING POINT (INDICATE IF “F” OR “C”): 174-212 F VAPOR PRESSURE (mm Hg): 23 @ R.T. VAPOR DENSITY (AIR = 1): 2.1 SPECIFIC GRAVITY (H2O=1): 0.9164...
  • Page 22 Date Printed: 09-26-1997          Page 3 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 6 — Section V – Fire and Explosion Hazard Data (continued) UNUSUAL FIRE AND EXPLOSION HAZARDS: Vapors form from this product and may travel or be moved by air currents and ignited by pilot lights or other ignition sources.
  • Page 23 Date Printed: 09-26-1997          Page 4 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 7 — Section VI – Health Hazard Data (continued) EFFECTS OF REPEATED OVEREXPOSURE: Long-term repeated overexposure to methanol vapor concentrations of 3000 ppm or greater may allow a cumulative effect to occur w/ resulting nausea, vomiting, headache, ringing in the ears, insomnia, trembling, unsteady gait, vertigo, clouded double vision.
  • Page 24 Date Printed: 09-26-1997          Page 5 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 8 — Section VII – Reactivity Data STABILITY (choose one): ( ) UNSTABLE ( x ) STABLE * CONDITIONS TO AVOID: None. INCOMPATBILITY (MATERIALS TO AVOID): Strong oxidizers, strong inorganic acids.
  • Page 25 Date Printed: 09-26-1997          Page 6 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 11 — Section X – Shipping Data D.O.T. SHIPPING NAME: FLAMMABLE LIQUIDS, N.O.S. (contains Ethanol) PRODUCT NAME: CAMPBELL SCIENTIFIC CS705 ANTIFREEZE D.O.T. HAZARD CLASS: 3 U.N./N.A. NUMBER: UN-1993 (PG II) PRODUCT RQ: N/A/ D.O.T.
  • Page 26 Date Printed: 09-26-1997          Page 7 Interstate Chemical Co. MSDS for CAMPBELL SCIENTIFIC CS705 ANTIFREEZE 1899-- 12 — Section XI – Special Precautions (continued) TRANSFER HAZARD – Vapors of this product may be ignited by static sparks. 13 — Section XII – SARA Title III...
  • Page 27 Campbell Scientific Regional Offices Australia France Thailand Location: Garbutt, QLD Australia Location: Vincennes, France Location: Bangkok, Thailand Phone: 61.7.4401.7700 Phone: 0033.0.1.56.45.15.20 Phone: 66.2.719.3399 Email: info@campbellsci.com.au Email: info@campbellsci.fr Email: info@campbellsci.asia Website: www.campbellsci.com.au Website: www.campbellsci.fr Website: www.campbellsci.asia Brazil Germany Location: São Paulo, SP Brazil...