KEP S12 Assembly, Installation And Operation

KEP S12 Assembly, Installation And Operation

Multi-input peripheral display

Advertisement

Quick Links

S12 MULTI-INPUT PERIPHERAL DISPLAY
INSTALLATION AND OPERATION
INDEX
FEATURES ....................................................................................................................................... 2
DESCRIPTION.................................................................................................................................. 2
SPECIFICATIONS ............................................................................................................................ 2
STROBE INPUT................................................................................................................................ 3
PARALLEL DATA INPUT.................................................................................................................. 3
MULTIPLEX DATA INPUT................................................................................................................ 3
DIP SWITCH SELECTION................................................................................................................ 3
DIMENSIONS ................................................................................................................................... 5
MOUNTING INSTRUCTIONS .......................................................................................................... 5
WIRING ............................................................................................................................................. 5
RIBBON CABLE WIRING ................................................................................................................. 6
SAMPLE WIRING 6 DIGIT PARALLEL ............................................................................................ 7
SAMPLE WIRING: 4 DIGIT MULTIPLEX INPUT ............................................................................. 8
RIBBON CABLE / P.C. BOARD DESIGNATIONS ........................................................................... 9
Warranty............................................................................................................................................ 9
Decoding Part Number
EXAMPLE
Series
S12: 12 to 24 V Operation
Number of Digits
4: 4 Digits
6: 6 Digits
Terminations
X: Screw Terminal with Ribbon Adapter "X"
(Order Ribbon Cable separately)
Input Type
1: Sourcing (User drives inputs positive, to + DC
4: Sinking (User pulls inputs negative, to -DC
Kessler Ellis Products
10 Industrial Way East
Eatontown, NJ 07724
800-631-2165 • 732-649-7100
Fax: 732-649-7099
Website: www.kep.com
S12
6
X
1
1
99232 12MAY04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KEP S12

  • Page 1: Table Of Contents

    SAMPLE WIRING: 4 DIGIT MULTIPLEX INPUT ................8 RIBBON CABLE / P.C. BOARD DESIGNATIONS ................9 Warranty............................9 Decoding Part Number EXAMPLE Series S12: 12 to 24 V Operation Number of Digits 4: 4 Digits 6: 6 Digits Terminations X: Screw Terminal with Ribbon Adapter "X"...
  • Page 2: Features

    4 data lines by strobing the 6 individual strobe lines. The minimum strobe pulse is 1 msec. but the S12 can be set by dip switch to react only to longer pulses. This prevents data from being entered by noise signals. If the strobe input is held at "Display Update"...
  • Page 3: Strobe Input

    The polarity of the strobe is set by SW2. Minimum strobe pulse is 1 mSec. The S12 can be set by SW7 and SW8 to react only to longer pulses, thus preventing data from being entered by noise signals. If the strobe is held at " Display Update"...
  • Page 4 FRONT SELECT SWITCHES 8.8.8.8.8.8. SW 6: DISPLAY CODES 1 = HEX CODE 0= “B"CODE DATA HEX CODE "B" CODE 8421 DISPLAY DISPLAY 0000 1 2 3 4 5 6 7 8 0001 0010 DIP SWITCH SETTING 0011 1 = ON (DOWN), 0 = OPEN (UP) 0100 0101 SW 1: DATA INPUT MODE...
  • Page 5: Dimensions

    MOUNTING INSTRUCTIONS The S12 is mounted in a 3.662” by 1.772" panel cutout - The screw terminal adapter and the 2 side mounting brackets must be removed so that the S12 may be inserted through the panel cutout. After the unit is inserted into the panel place the two side brackets into the side grooves.
  • Page 6: Ribbon Cable Wiring

    12 inches. Part Number: S12RX- Specify number of units to be linked together. Example: *S12RX4 is cable to connect four S12 units spaced 12 inches apart. *For special lengths consult factory. S12 ADAPTOR "X" FOR RIBBON CABLE Jumper (Already supplied as termination "X"...
  • Page 7: Sample Wiring 6 Digit Parallel

    SUPPLY + *STROBES TB1 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 S12 DISPLAY TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 100K 4...
  • Page 8: Sample Wiring: 4 Digit Multiplex Input

    TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 S12 DISPLAY ALL DATA FROM PLC (D1, D2, D4, D8) IS ENTERED INTO MULTIPLEX INPUTS (TB1 - PINS 7, 8, 9 AND 10). STROBES LATCH THE DATA, ONE DIGIT AT A TIME, INTO THE PROPER DIGIT.
  • Page 9: Ribbon Cable / P.c. Board Designations

    We hope you will be pleased with our products. If you have any questions concerning our warranty, repair, modification or returned goods process, please contact your local KEP distributor or the KEP Customer Service Department. Warranty This product is warrantied against defects in materials and workmanship for a period of one (1) year from the date of shipment to buyer.

Table of Contents