MOUNTING INSTRUCTIONS
SHORTENING ELEMENTS
GRADES 80 AND 100
9. INSPECTION, MAINTENANCE, DISPOSAL
9.1 General
Inspections and maintenance must be arranged by the owner!
Inspection intervals must be determined by the owner!
Visual inspections must be regularly carried out and
documented by competent and trained persons, at least once a
year or more frequently if the shortening elements are in heavy
duty service. After three years at the latest they must
additionally be examined for cracks. A load test is not a
substitute for this examination.
The results of the inspection shall be kept in a file that has to be
set up for each sling chain before first use. The register shall
show characteristic data of the chains and components as well
as identity details.
Immediately stop using shortening elements that show the
following defects:
• missing or illegible identification/marking
• deformation, elongation or fractures of chains or
components
• cuts, notches, cracks, incipient cracks, pinching
• links heated beyond permissible limit
• severe corrosion
• reduction of the averaged pin diameter by more than 10 %
as mean value of measurements taken perpendicularly
towards each other
• impaired or missing safety systems
• missing or damaged dowel pins.
Cleaning (e.g. prior to inspections) must not take place by using
flames or methods that might cause hydrogen embrittlement
(e.g. pickling or immersion in acidic solutions).
9.2 Inspection service
THIELE offers inspection maintenance and repair services by
trained and competent personnel. Please contact us for further
information.
9.3 Maintenance and repair
Maintenance and repair work must only be performed
by competent and trained persons.
The movable safety pins and bolts should be checked regularly
for their function and lubricated with multi-purpose oil or grease
when installed. Then operate the securing elements several
times to spread the lubricant.
THIELE GmbH & Co. KG
www.thiele.de | info@thiele.de
© All rights reserved.
#
Minor notches and cracks may be eliminated by careful grinding
observing the maximum cross section reduction requirement of
max. 10 % and avoid making more severe cuts or scores.
All maintenance and repair activities must be documented
properly.
9.4 Disposal
All steel components and accessories taken out of service must
be scrapped in accordance with local regulations and provisions.
10. STORAGE
Shortening elements must be stored properly sorted and in dry
conditions at temperatures between 32 °F and 104 °F.
Do not store in a manner that causes mechanical damage.
11. INSTRUCTIONS DOWNLOAD
Current mounting and operating instructions are available as a
PDF download on the THIELE-website www.thiele.de.

12. PUBLISHING INFORMATION

KWS Inc.
Company
(Distributor)
P.O. Box 470487
Postal
Tulsa, OK 74147
address
USA
Phone
+1 (539) 367 2274
number
Fax number
+1 (539) 367 2278
Email
sales@kwschain.com
B11095-D
US 12.2021
#
THIELE GmbH & Co. KG
(Manufacturer)
Werkstrasse 3
58640 Iserlohn
Germany
+49 2371/947-0
+49 2371/947-241
info@thiele.de
# change indicator
replaces B11095-C
7 | 7

Advertisement

loading

This manual is also suitable for:

Twn 0827Twn 1827/1Twn 1827Twn 0851Twn 1851Twn 0851/1 ... Show all