2 About CM – Connect ....................7 Purpose of this manual....................8 Use of symbols......................8 3 Installation ........................9 Setting up the CM Connect..................11 Link CM to CM Connect (gateway)................13 4 Safety ..........................15 Safety – Installation....................15 Product........................15 Recycling information....................15 5 Addendum ........................17...
Compagny Name Albuen 31, 6000 Kolding, Denmark Address +45 79 32 22 00 Phone No hereby declare that Alfa Laval CM Connect Condition Monitor Designation Type EU Conformities EN 301 489-52: V1.1.2: 2020, Class A EN 301 489-1 V2.2.3: 2019, Class A...
Page 6
1 EC Declaration of Conformity www.sks-online.com 200005871-1-EN-GB www.sks-webshop.com...
PC or handheld device. The CM Connect can be connected to up to 10 Alfa Laval Condition Monitors (CM) via Bluetooth which measures equipment vibration and temperature. The measurements are compared against a baseline set during an initial “Teach”...
Alfa Laval CM Connect App. Requesting other information for instructions, situations, or events that are not considered in this manual or in the sales documents, please contact your local Alfa Laval representative. Always specify the exact product type and identification code when requesting technical information or spare parts.
2. Equipment mounted acting as gateway and a sensor (for mounting on Alfa Laval equipment – see separate Addendums). The CM Connect should be mounted on the wall utilizing two flat or conehead screws (not included). 86 mm / 3.38”...
Page 10
PIN2 Future option PIN3 Power supply GND (blue) PIN4 Future option Power connector cables can be ordered through Alfa Laval using following article numbers: 4 wire female Cable M12 5m [15Ft] length For wall mount 8010000288 straight connector 4 wire female...
3.1 Setting up the CM Connect NOTE Ensure there is mobile coverage at the installation location. Mount the CM Connect (for wall mount see section 3 and for Alfa Laval equipment mount see relevant addendum). Connect M12 cable to power (order separately) as illustrated in section 3.
Page 12
Searching for cellular network. (Single blinking led). b) Connected to cellular network. (Double blinking led). c) Connected to CM-Connect server. (Pulsating heartbeat led). 2067-0027 If there are any issues during the registration process please contact Alfa Laval Customer Support connectsupport@alfalaval.com www.sks-online.com 200005871-1-EN-GB www.sks-webshop.com...
Installation 3 3.2 Link CM to CM Connect (gateway) Install and commission the CM on the equipment as described in the CM manual. Now enter the setup screen and scan for CM’s (the CM’s must be within Bluetooth range from the CM Connect.
Attention Only expose the CM Connect to ambient temperatures within −30℃ to 70℃ [22°F to 158°F]. Heating above these temperatures could result in serious injury. Never dispose of the CM Connect in a fire, this could result in serious injury.
Need help?
Do you have a question about the CM Connect and is the answer not in the manual?
Questions and answers