Table 13 — Fan Performance, 48EJ,EK038,044 — Vertical Discharge Units
(For EW/EY units, reduce net available external static pressure by 0.5 in. wg)
AIRFLOW
0.2
(Cfm)
Rpm
Bhp
Rpm
7,000
429
1.70
8,000
475
2.36
9,000
523
3.11
10,000
571
4.00
11,000
620
5.04
12,000
670
6.24
13,000
720
7.61
14,000
771
9.15
15,000
822
10.88
16,000
873
12.80
17,000
924
14.91
18,000
976
17.24
19,000
1027
19.77
1050
20,000
1079
22.53
1100
AIRFLOW
1.8
(Cfm)
Rpm
Bhp
Rpm
7,000
794
5.20
8,000
813
6.06
9,000
835
7.09
10,000
862
8.28
11,000
891
9.64
12,000
924
11.18
13,000
958
12.91
14,000
995
14.83
1021
15,000
1033
16.96
1058
16,000
1073
19.31
1097
17,000
1114
21.88
1137
18,000
1156
24.69
1178
19,000
20,000
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
AIRFLOW
3.4
(Cfm)
Rpm
Bhp
7,000
1066
8.88
8,000
1072
9.88
9,000
1083
11.04
10,000
1098
12.37
11,000
1117
13.86
12,000
1139
15.54
13,000
1164
17.41
14,000
1191
19.48
15,000
16,000
17,000
18,000
19,000
20,000
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
0.6
Bhp
Rpm
Bhp
484
2.40
536
2.70
525
3.09
571
3.49
567
3.97
610
4.39
612
5.01
651
5.46
658
6.22
694
6.69
705
7.61
738
8.10
752
9.19
784
9.70
801
10.97
830
11.51
850
12.95
877
13.52
899
15.16
925
15.74
949
17.59
974
18.20
999
20.26
1023
20.88
23.17
1072
23.82
26.33
1122
27.00
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.0
2.2
Bhp
Rpm
Bhp
832
5.62
868
6.06
848
6.52
883
6.98
869
7.56
902
8.04
893
8.77
925
9.27
921
10.15
951
10.67
952
11.71
980
12.24
986
13.45
1012
14.01
15.40
1046
15.97
17.55
1082
18.14
19.92
1120
20.52
22.51
1159
23.13
25.33
1199
25.98
3.6
3.8
Rpm
Bhp
Rpm
1096
9.38
1125
1101
10.39
1130
1111
11.56
1139
1125
12.90
1152
1143
14.41
1169
1164
16.11
1189
1188
17.99
0.8
1.0
Rpm
Bhp
Rpm
Bhp
584
3.10
630
3.50
616
3.90
658
4.31
651
4.82
690
5.26
689
5.91
725
6.37
729
7.17
763
7.65
771
8.60
803
9.11
814
10.23
844
10.75
859
12.05
887
12.60
904
14.08
931
14.65
951
16.33
976
16.92
998
18.80
1022
19.41
1046
21.51
1068
22.14
1094
24.46
1115
25.11
1142
27.66
1163
28.33
2.4
2.6
Rpm
Bhp
Rpm
Bhp
903
6.52
937
6.98
916
7.45
949
7.92
934
8.53
965
9.02
955
9.77
985
10.28
980
11.19
1008
11.71
1008
12.78
1035
13.32
1039
14.56
1064
15.13
1071
16.55
1096
17.13
1106
18.73
1130
19.33
1143
21.14
1165
21.75
1181
23.76
LEGEND
Bhp
9.88
Bhp — Brake Horsepower
10.90
NOTES:
12.08
1. Fan performance is based on wet coils, economizer, roof curb,
13.44
cabinet losses, and clean 2-in. filters.
14.96
2. Conversion — Bhp to watts:
16.68
Watts =
Motor efficiency
3. Variable Air Volume units will operate down to 70 cfm/ton. Per-
formance at 70 cfm/ton is limited to unloaded operation and may
be additionally limited by edb (entering dry bulb) and ewb (enter-
ing wet bulb) conditions.
36
1.2
1.4
Rpm
Bhp
Rpm
Bhp
674
3.90
716
4.30
699
4.74
738
5.17
728
5.71
765
6.16
761
6.84
795
7.31
796
8.14
829
8.64
834
9.62
865
10.13
874
11.29
902
11.82
915
13.15
942
13.71
957
15.22
983
15.80
1001
17.51
1025
18.11
1045
20.03
1069
20.64
1091
22.77
1113
23.41
1137
25.76
1158
26.42
1183
29.00
2.8
3.0
Rpm
Bhp
Rpm
Bhp
971
7.44
1003
7.92
981
8.40
1012
8.89
995
9.52
1025
10.02
1014
10.79
1043
11.31
1036
12.24
1064
12.78
1062
13.87
1088
14.42
1090
15.69
1115
16.26
1120
17.71
1144
18.29
1153
19.93
1176
20.54
1188
22.37
Bhp x 746
1.6
Rpm
Bhp
756
4.80
776
5.61
801
6.62
829
7.79
860
9.14
894
10.65
931
12.36
969
14.27
1008
16.38
1049
18.71
1092
21.26
1135
24.05
1179
27.07
3.2
Rpm
Bhp
1035
8.40
1042
9.38
1054
10.53
1071
11.84
1090
13.32
1114
14.98
1140
16.83
1168
18.89
1199
21.14