Technical Specification Energy Efficiency Class Nominal Heat Output Wood 4,9kW 4,9kW Energy Efficiency Efficiency Wood Mean CO (@13% O₂) Wood 0.20% 0.20% Appliance Mass 116kg 116kg Recommended Fuels Wood Seasoned Wood (less than 20% moisture content) Log Length 330mm 330mm Mean Flue Gas Temperature Wood 269°C 269˚C...
It is important that your stove is correctly installed and Special care must be taken when installing the stove operated as Hunter Stoves Group cannot accept such that the requirements of the Health and Safety responsibility for any fault arising through incorrect at Work Act are met.
Page 5
DO NOT OVER-FIRE – it is possible to fire the stove If the wall is becoming excessively hot, move furniture beyond its design capacity. This could damage the away. Ensure the Fire Brigade can gain access to your stove so watch for signs of over-firing. If any part of roof space in order to check for fire spread.
BS EN 1856 can be used. These chimneys must be fitted in accordance with the manufacturer’s instructions and Building Regulations. DI LUSSO R6 SLIMLINE The chimney/flue should have a vertical height of at least 4.5 metres and should terminate in accordance with Table 2.
DI LUSSO R6/R6 SLIMLINE APPLIANCE OPENING This stove must be fitted on a hearth or base with adequate load bearing capacity. The opening into which this stove is fitted should be constructed wholly from non-combustible materials. The dimensions of the opening should be at least those shown in the diagram.
Page 9
Please check the suitability of any fireplace/surround for closed solid fuel appliances before installation. Di Lusso cannot be held responsible for any fault arising through incorrect use or installation. Fire surround back panels suitable for solid fuel are usually in three sections and slabbed.
Page 10
PREPARING THE STOVE FOR INSTALLATION The firebox must be separated from the outer convection chamber prior to fitting the stove. This allows easier handling of the stove and protects the internal firebox from damage during the installation process. It is also recommended that the loose internal components (fire bricks and log retainer) within the firebox are removed.
the screw heads are not proud of the flue ITTING THE TOVE – BOTH collar flange. IMPORTANT – Read this section carefully and ensure that any required access holes, register plates or flue connections are in place before carrying out the installation.
NSTALLATION INTO A NON COMBUSTIBLE ENCLOSURE BOTH The Di Lusso R6 and R6 Slimline has been designed, tested and approved to be installed either into solid non-combustible material or into an enclosure according to the following specification. It is the duty of the installer to ensure that the requirements of this specification and all relevant standards are met.
Page 13
Di Lusso R6/R6 Slimline Enclosure Details (all dimensions in millimetres) Internal heat shield All panels including heat shield to be produced from 30mm Skamol Super Isol Board Internal heat shield N.B. Ventilation openings are identical on both sides of the enclosure.
RE-ASSEMBLING THE STOVE 11. Stack the two baffle halves with the right- hand baffle sat on top of the left-hand baffle 1. Smear a bead of fire cement around the flue as shown – hole on the outside of the firebox. Fire Cement 2.
13. Slide the Left hand baffle to the left and the 4. Offer the door fascia into position, passing the right hand baffle to the right, push them three M6 studs through the holes. Ensure that towards the rear of the firebox so that the the fascia is resting on the two clips at the top baffles drop down and sit tightly together as of the door and fix in position using the nuts...
Page 16
Do not burn requirements. waste, coal or petroleum coke fuels or treated or The Di Lusso R6 and R6 Slimline have been painted wood in this appliance (e.g. pallet wood) as recommended as suitable for use in smoke control this will invalidate your warranty.
Page 17
To prevent excess smoke emissions, the air controls helps to reduce emissions into the atmosphere. The of this appliance must only be operated as directed tertiary air supply is fixed and cannot be adjusted. in the instructions. N.B. When closing the door, keep the door handle out to the right until the door is closed.
When the stove is up to operating temperature, the appliance requires regular maintenance of the operating tool or gloves should be used to operate following – the air controls. N.B. Refer to the ‘Removing Internal Components’ section of the installation instructions for details on how to remove each component.
• The door is tightly closed. based or other cleaning products be used on the • stove. The finish can be renovated with Hunter Stoves The air controls are in the closed position. • paint. A suitable fuel is being used.
This is needed in the event of a claim during the warranty period. Only genuine Hunter Stoves spare parts or consumables can be used in the servicing and maintenance of the appliance during any standard or extended warranty period. These can be sourced from your authorised supplier directly or through our website spares portal.
Page 26
Cost associated with the removal and re-installation of an appliance subject to a warranty claim. Hunter Stoves Group total liability will only extend to the total purchase price paid for the goods in any warranty claim. Hunter Stoves Group reserve the right to replace, repair or refund to value of goods purchased.