Find out if you are in a Smoke Control Area by contacting your Local Authority. The Stromstad, Atta and Sju are fitted with a permanent stop. Without the permanent stop in place the appliance is not an exempt appliance and so may leave the householder liable for a fine up to £1000.
INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERANCE AND SERVICING. THIS APPLIANCE WILL BECOME VERY HOT WHEN USED IN ACCORDANCE WITH THESE INSTRUCTIONS, HUNTER STOVES RECOMMEND THAT AN APPROVED GUARD IS USED TO PROTECT THE YOUNG, ELDERLY OR INFIRM FROM HARM.
ARBON ONOXIDE ETECTOR operating tool or glove may be used to open the door Hunter Stoves recommend a Carbon Monoxide and operate the air controls. Detector that conforms to the latest issue of BS EN AEROSOLS 50292 is placed in the same room as the appliance.
APPLIANCE DIMENSIONS ONNECTION TO THE HIMNEY An existing fireplace opening can be bricked up or sealed with a register plate. A short length of flue pipe of minimum 150mm internal diameter may then be used to connect the stove to the chimney. This flue pipe should be made of 316 grade stainless steel or vitreous enamelled steel, nominal thickness 1.2mm.
The room or space containing this appliance does not need a permanent, unobstructed air opening. EGAL EQUIREMENTS Hunter Stoves Group requests that before installation If a draught stabiliser is fitted, the air opening should and/or use of this appliance that you read these be at least 1410mm².
front of the stove. The stove should stand wholly Material Clearances above a solid, non-combustible hearth, at least 125 Minimum Distances to mm thick (this may include the thickness of a solid floor and a non-combustible decorative hearth). Combustible Material FREE-STANDING BOTH Behind the stove 15mm (Behind...
5. Remove the baffle brick by lifting it up, sliding it to the right and then lowering it into the firebox. Removing Internal Components 1. Open the door as detailed in the ‘Operating Instructions’ section. 2. Remove the ash pan by simply pulling it out by its 4.
Installation Requirements NSTALLATION 4. Remove the top plate by simply lifting it off. IRECT DAPTOR If fitting the direct air adaptor kit, read the instructions supplied with the kit before proceeding. Please note that Direct Air is not available on the Strömstad Sju model.
Please check that all components are correctly assembled and working correctly. Ensure the Air Controls are working correctly. Hunter Stoves Group recommend that you carry out a smoke draw test to check the soundness of the chimney/flue system and seals: Place a Smoke Pellet in the centre of the Grate, 10.
Page 12
Minimum Draught – 1.2mm Water Gauge Maximum Draught – 2.5mm Water Gauge The Stromstad, Atta, Sju has been fitted with a stop to prevent the secondary air valve from completely THE CLEAN AIR ACT 1993 AND SMOKE CONTROL AREAS Under the Clean Air Act local authorities may declare the closing.
The following procedure should only be carried out if During this curing in process you may notice an the stove is NOT installed in a smoke control area. unpleasant smell. It is non-toxic, but for your comfort we would suggest that during this period you leave all doors and windows open.
Page 14
downwards to re-engage the locking mechanism and seal the door. Lighting the Stove Open both air controls fully and light one or two firelighters placed centrally on the bottom grate, allowing the flames to become established before placing several pieces of small dry kindling in a criss- cross fashion above the firelighters, taking care not to smother the fire.
Recommended Fuels AFFLE Hunter Stoves Group recommend that only wood logs This should be removed and cleaned at least once a with a moisture content of less than 20% and month to prevent any build-up of soot or fly ash that...
Page 16
If the rope is in a poor condition, a replacement rope kit may be ordered from the Hunter Stoves Group spares range. HIMNEY AND LUE WAYS It is important that the chimney, flue ways and any connecting flue pipe are swept regularly.
TROUBLESHOOTING ISSUE CAUSE RESOLUTION Problem starting the fire and Low flue draught Speak to your installer keeping it burning Wood with moisture content over 20% Ensure use of dry seasoned wood with less than 20% moisture content Unable to control fire High flue draught Speak to your installer Short burn time...
Page 18
ISSUE CAUSE RESOLUTION Creosote build-up in chimney Wood with moisture content over 20% Use dry seasoned wood (less than 20% moisture content). Operate at a high temperature for short periods each time the appliance is used to avoid large build-ups of tars and creosotes.
INSTALLATION & COMMISSIONING CHECKLIST PURCHASE INFORMATION Dealer/Retailer Name Address Telephone Number Email Date Purchased INSTALLER INFORMATION Installer Name Address Telephone Number Email APPLIANCE INFORMATION Date Installed Appliance Stock Code Appliance Description Serial Number COMMISSIONING CHECK (Complete & Sign) Does the chimney/flue system meet the appropriate standard? Has the chimney/flue system been swept and passed the soundness test? Has this appliance passed the flue draught test? Please write down the flue draught reading:...
SERVICE RECORDS Service Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company/ Servicing Company/ Engineer Engineer Signature Signature Service Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company/ Servicing Company/ Engineer...
4. Only genuine Hunter Stoves spare parts or consumables can be used in the servicing and maintenance of the appliance during any standard or extended warranty period. These can be sourced from your authorised supplier directly or through our website spares portal.
Page 25
7. Cost associated with the removal and re-installation of an appliance subject to a warranty claim. Hunter Stoves Group total liability will only extend to the total purchase price paid for the goods in any warranty claim. Hunter Stoves Group reserve the right to replace, repair or refund to value of goods purchased.
Page 26
Further Information For extra guidance on using your stove, please visit our YouTube channel by searching ‘Hunter Stoves Group’ or see the helpful hints section of our website; www.hunterstoves.co.uk. This appliance is suitable for intermittent burning. This appliance should not be used in a shared flue.
Need help?
Do you have a question about the Stromstad and is the answer not in the manual?