ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE
Electrostatic discharge can affect electronic components.
Take precautions during furnace installation and servicing to
protect the furnace electronic control. Precautions will pre-
vent electrostatic discharges from personnel and hand tools
which are held during the procedure. These precautions will
help to avoid exposing the control to electrostatic discharge
by putting the furnace, the control, and the person at the same
electrostatic potential.
1. Disconnect all power to the furnace. DO NOT TOUCH THE
CONTROL OR ANY WIRE CONNECTED TO THE CON-
TROL PRIOR TO DISCHARGING YOUR BODY'S ELEC-
TROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the furnace
chassis which is close to the control. Tools held in a person's
hand during grounding will be satisfactorily discharged.
3. After touching the chassis you may proceed to service the
control or connecting wires as long as you do nothing that
recharges your body with static electricity (for example; DO
NOT move or shuffle your feet, DO NOT touch ungrounded
objects, etc.).
4. If you touch ungrounded objects (recharge your body with
static electricity), firmly touch furnace again before touching
control or wires.
5. Use this procedure for installed and uninstalled (ungrounded)
furnaces.
6. Before removing a new control from its container, discharge
your body's electrostatic charge to ground to protect the
control from damage. If the control is to be installed in a
furnace, follow items 1. through 5. before bringing the control
or yourself into contact with the furnace. Put all used AND
new controls into containers before touching ungrounded
objects.
7. An ESD service kit (available from commercial sources) may
also be used to prevent ESD damage.

CARE AND MAINTENANCE

For continuing high performance and to minimize possible equip-
ment failure, it is essential that periodic maintenance be performed
on this equipment. Consult your local dealer as to proper frequency
of maintenance and availability of a maintenance contract.
Never store anything on, near, or in contact with furnace, such
as:
1. Spray or aerosol cans, rags, brooms, dust mops, vacuum
cleaners, or other cleaning tools.
2. Soap powders, bleaches, waxes or other cleaning com-
pounds, plastic or plastic containers, gasoline, kerosene,
cigarette lighter fluid, dry cleaning fluids, or other volatile
fluids.
3. Paint thinners and other painting compounds, paper bags or
other paper products. A failure to follow this warning could
result in corrosion of the heat exchanger, fire, personal injury,
or death.
Turn off gas and electrical supplies to unit before performing
any maintenance or service on it. Follow operating instruc-
tions on label attached to furnace. A failure to follow this
warning could result in personal injury.
The minimum maintenance that should be performed on this
equipment is as follows:
1. Check and clean air filter each month or more frequently if
required. Replace if torn.
2. Check blower motor and wheel for cleanliness each heating
and cooling season. Clean as necessary.
3. Check electrical connections for tightness and controls for
proper operation each heating season. Service as necessary.
As with any mechanical equipment, personal injury can result
from sharp metal edges, etc.; therefore, be careful when
removing parts.
Step 1—Cleaning and/or Replacing Air Filter
The air filter arrangement may vary depending on application.
NOTE: If the filter has an airflow direction arrow, the arrow must
point toward the blower.
Never operate unit without a filter or with filter access door
removed. A failure to follow this warning could result in fire,
personal injury, or death.
To clean or replace filters, proceed as follows:
1. Filters installed in media cabinet adjacent to furnace (see Fig.
2)
MOUNTING
SCREWS
RELIEF
BOX
GAS
VALVE
CONTROL
Fig. 2—Model 58YAV Upflow Furnace
a. Turn off electrical supply to furnace
b. Remove filter cabinet door.
c. Slide filter out of cabinet.
2
FLUE
COLLAR
BLOCKED
VENT
SAFEGUARD
PRESSURE
SWITCH
FLUE
COLLECTOR
BOX
FILTER
RETAINER
HUM
WASHABLE
FILTER
A99284