GÜDE Expert Sensor Box 7213 Manual
Hide thumbs Also See for Expert Sensor Box 7213:

Advertisement

Quick Links

Manual
Expert Sensor Box 7213
Expert Sensor Box 7214
© 2022 GUDE Systems GmbH
Manual Ver. 1.3.1
from Firmware Ver. 1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Expert Sensor Box 7213 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GÜDE Expert Sensor Box 7213

  • Page 1 Manual Expert Sensor Box 7213 Expert Sensor Box 7214 © 2022 GUDE Systems GmbH Manual Ver. 1.3.1 from Firmware Ver. 1.3...
  • Page 2 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 3: Table Of Contents

    3.4.6 MQTT ........................38 Clock ..........................39 3.5.1 NTP ......................... 39 3.5.2 Timer ........................40 3.5.3 Timer Configuration ....................40 Sensors .......................... 47 3.6.1 Port Switching ......................48 E-Mail ..........................49 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 4 4.9.1 Sensor Tables ......................89 4.10 MQTT ..........................89 4.10.1 Example HiveMQ ....................92 Support Data Security ........................ 95 Contact .......................... 95 Declaration of Conformity ..................96 FAQ ..........................96 Index Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 5 Device Description...
  • Page 6: Device Description Security Advice

    · Power supply unit 7903 (12V DC, 1 A) (for 7213-1, 7213-2, 7213-3) · Quick Start Guide Description Depending on the model, the Expert Sensor Box 7213 / 7214 offers several environ- mental sensors. The device has the following features: Devices with voltage input: ·...
  • Page 7: Installation

    · Passive signal input for polling NO/NC devices (e.g., smoke detector, leak sensor, door contact) · The signal input has a 12 V connector for supplying the NO/NC devices Installation 1. Connector Sensor Port 1 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 8: Terminal Assignment

    · Attach the optional external sensors to the connectors. · Connect the passive inputs and relay outputs to compatible devices. 1.4.1 Terminal Assignment The terminal assignment of the terminals is printed on the housing surface: Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 9: Redundant Voltage Supply

    If both power supplies (only ESB 7214) are connected at the same time, the current is split up. The current distribution depends on the difference between the output voltages of the two power supplies. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 10: Technical Specifications

    Connector for switching outputs and signal inputs: System terminal 3-pole AK1550/3-3.5-GREEN Sensor Two external sensors can be connected to the Expert Sensor Box 7213 / 7214. The fol- lowing sensors are currently available Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 11 ± 1 hPa (typical) (full) at 300 ... 1100 hPa, 0 ... +40 °C air pressure range ± 1.7 hPa (typical) (ext) at 300 ... 1100 hPa, -20 ... 0 °C Protection IP68 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 12 A click on the link in the "Name" column opens the display of the Min and Max values. The values in a column can be reset using the "Reset" button. The "Reset" button in the name column deletes all stored Min and Max values. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 13: Operating

    Operating...
  • Page 14: Operating The Device Directly

    The web page provides an overview of the switching state, the sensor, as well as the ex- ternal sensors, provided that they are connected. When the port is clicked, a panel with buttons to control the port appears: Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 15 The web page contains a status overview of the passive signal input, the time since the last change, and a counter of the switching cycles. The name and text for a logical state of the input is configured in the chapter Configuration-Input Ports Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 16: Maintenance

    If an older firmware is newly installed, the configuration data and the energy meters may be lost! If the device then does not run correctly, please restore the factory settings (e.g. from the Maintenance Page Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 17 · Enter the desired settings in the edit window and save them with "Save Config". · Deactivate the boot loader mode for the changes to take effect. Select again "All Devices" in the "Search" menu of GBL_Conf.exe. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 18: Maintenance Page

    This section provides access to important functions such as Firmware Update or Restart Device. It is advisable to set an HTTP password for this reason. Firmware Update: Start a firmware update. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 19: Configuration Management

    (even if it is encrypted or hashed). For the same reasons, it is advisable to carefully handle the generated configuration files when archiv- ing. Editing the configuration file Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 20 0 #range: 0..2 email auth set 0 #range: 0..2 email user set "" #len: 0..100 email passwd hash set "" #len: 0..100 email enabled set 1 #range: 0..1 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 21: Bootloader Activation

    If a display is available, "Press again to jump to FIRMWARE" appears. Then briefly press the button again to activate the boot loader, or if you wait 6 seconds in- stead, the device returns to the initial state. 2) or Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 22 · In menu "Program Device" activate the item "Reset to Fab Settings" · The status LED will blink in a fast rhythm, please wait until the LED blinks slowly (about 5 seconds) Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 23: Configuration

    Configuration...
  • Page 24: Output Ports

    Initialization delay: Here can be configured how long the port should wait to switch to its defined state after the device is turned on. The delay may last up to 8191 seconds. This Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 25: Watchdog

    You can monitor devices on your own network, as well as devices on an external net- work, e.g. the operating status of a router. Enable watchdog: Enables the watchdog function for this Power Port. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 26 If this option is activated, a watchdog is also triggered if the Ethernet link is down. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 27: Input Ports

    On input is LOW: Switching action when Input Port changes from HI to LOW. Console push-messages This option allows the output of sensor values on the console at a configured time interval, or when a certain threshold has been reached. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 28: Ethernet

    During this time the IP-address is not accessible! It is therefore essential to deactivate DHCP for a static IP addresses! Use IPv6 Protocol: Activates IPv6 usage. Use IPv6 Router Advertisement: The Router Advertisement communicates with the router Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 29 The input fields for the manual setting of IPv6 addresses allow you to configure the prefix of four additional IPv6 device addresses, and to set two DNS addresses, and a gateway. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 30: Ip Acl

    If you choose a wrong IP ACL setting and locked yourself out, please activate the Bootloader Mode and use GBL_Conf.exe to deactivate the IP ACL. Alternatively, you can reset the device to factory default. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 31: Http

    Users can log in by entering the user password in order to query the status information and initiate switching operations. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 32: Protocols

    SHA2-256 hash. If you want to change a password, the complete password must always be re-entered. If you have forgotten your password, please activate the bootloader mode and then turn off the password prompt in GBL_Conf.exe. Protocols 3.4.1 Console Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 33: Syslog

    Enable Syslog: Enables the usage of Syslog Messages. Syslog Server: If you have enabled Syslog Messages, enter the IP address of the server to which the syslog information should be transmitted. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 34: Snmp

    Because of security issues, it is advisable to use only SNMP v3, and to disable SNMP v2. Accesses to SNMP v2 are always insecure. Community public: The community password for SNMP GET requests. Community private: The community password for SNMP SET requests. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 35 MIB table: The download link to the text file with the MIB table for the device. More information about SNMP settings are available from our support or can be found on the Internet at www.gude.info/wiki. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 36: Radius

    Backup Server: Name or IP address of the Radius Backup server. Shared secret: Radius Shared Secret. For compatibility reasons, only use ASCII charac- ters. Timeout: How long (in seconds) will be waited for a response from an Authentication Request. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 37: Modbus Tcp

    The "Test Radius Server" function allows you to check whether a combination of User- name and Password is accepted by the configured Radius Servers. 3.4.5 Modbus TCP Enable Modbus TCP: Enables Modbus TCP support. Modus TCP port: The TCP/IP port number for Modbus TCP. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 38: Mqtt

    [mac] and [host] symbolize the MAC address or the hostname of the device. Permit CLI commands: Enables the execution of console commands. Publish device data summary interval: Time interval in which messages with the global status of the device are sent. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 39: Clock

    Primary NTP server: IP address of the first NTP server. Backup NTP server: IP address of the second NTP server. Used when the first NTP server does not respond. Timezone: The set time zone for the local time. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 40: Timer

    This instruction chapter applies to all Gude devices. For devices without switchable ports you can only create a complex timer. For an action there is only the register "Ac- tion CLI" available, and not the register "Action PortSwitch". Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 41 "Save" saves this rule. We have now created 2 rules, one for when the port is turned on and the second for when it is turned off. Creating a complex timer Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 42 Ports are switched as action mode, alternatively a console command (CLI Cmd) can be executed. After changes to existing timers, the "Rule Name" may no longer be meaningful. To keep the overview, it may be useful to adjust the name. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 43 9:30 and 17:10 in a single timer rule. You need a second rule for this. If you set the hours 9 and 17, as well as the minutes 10 and 30, then the four times 9:10, 9:30, Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 44 In this example, port 1 and port 5 are enabled and disabled after 90 minutes by batch mode. A popup on the mouse pointer shows the port number of the field. Console Commands Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 45 Switch port 3 on every day at 9:25, and off again at 17:30. You save. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 46 The jitter of 1800 seconds means that the action is executed randomly in a period between 30 minutes before and 30 minutes after the programmed time. The probability (Random Trigger Probability) of execution here is 100%. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 47: Sensors

    This option allows the output of sensor values on the console at a configured time interval, or when a certain threshold has been reached. Min/Max measurement period: Selects the time range for the sensor min/max values on the overview web page. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 48: Port Switching

    Example with "Maximum value" of 65 °C, "Minimum value" of 25 °C and hysteresis of 3 ° C. The dotted line shows the hysteresis. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 49: E-Mail

    "On" or "Off" action is defined for a port, the port can never reach this state by ex- ceeding sensor values. Unless it is the initial state. E-Mail Enable E-Mail: Activates the E-Mail dispatch of messages. Sender address: The E-Mail address of the sender. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 50 If you want to change a password, the complete password must always be re-entered. E-Mail Logs: Logging of E-Mail system messages. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 51: Specifications

    Specifications...
  • Page 52: Automated Access

    JSON format. The structure of the CGI commands and the JSON data is explained in more detail in our Wiki article: http://wiki.gude.info/EPC_HTTP_Interface Messages Depending on adjustable events, various messages can be sent from the device. The fol- Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 53 Device started Switch port Port watchdog status Power-over-Ethernet ready Power supply status Syslog switched on/off MQTT connection established MQTT connection lost Value-Threshold external sensors Signal inputs Time-Interval external sensors Signal inputs Value-Delta Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 54: Ip Acl

    HTTP or SNMP, and make changes. For incoming connections from unauthor- ized PCs, the device is not completely transparent. Due to technical restraints, a TCP/IP connection will be accepted at first, but then rejected directly. Examples: Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 55: Ipv6

    The passwords for HTTP, telnet, and serial console (depending on the model) can be stored locally and / or authenticated via RADIUS. The RADIUS configuration supports a primary server and a backup server. If the primary server does respond, the RADIUS re- Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 56: Snmp

    MIB structure. Alternatively, each OID can be referred to with its symbol name (subtree name). The device's MIB table can be displayed as a text file by clicking on the link "MIB table" on the SNMP configuration page in the browser. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 57 Security The following aspects should be considered: · If encryption or authentication is used, then SNMP v1 and v2c should be turned off. Otherwise the device could be accessed with it. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 58 Name: snmpwalk -v2c -mALL -c public 192.168.1.232 gudeads OID: snmpwalk -v2c -mALL -c public 192.168.1.232 1.3.6.1.4.1.28507 NET-SNMP Examples Query Power Port 1 switching state: snmpget -v2c -mALL -c public 192.168.1.232 epc822XPortState.1 Switch on Power Port 1: Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 59: Device Mib 7213

    3. the output may show 2 lines - the 1st line shows the actual state, the 2nd line the status after reboot 4. the output may show several lines 5. N/A 6. Please see the External Sensor Field Table for the right sensor index Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 60: Device Mib 7214

    Mode of startup sequence (off, on , remember last state) esb7214PortStartupDelay .67.1.3.1.2.1.6.x Integer32 Delay in sec for startup action esb7214PortRepow erTime .67.1.3.1.2.1.7.x Integer32 Delay in sec for repow er port after sw itching off Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 61 6. Please see the External Sensor Field Table for the right sensor index External Sensor Type Table "{7x01=0|7x02=1|7x03=2}" Index Description Products Temperature 7001, 7101, 7201 Temperature, Humidity 7002, 7102, 7202 Temperature, Humidity, Air Pressure 7003, 7103, 7203 External Sensor Field Table "{sen_field}" Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 62: Ssl

    Here are some examples for the generation with OpenSSL: Creation of a self-signed RSA 2048-bit certificate openssl genrsa -out server.key 2048 openssl req -new -x509 -days 365 -key server.key -out server.crt Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 63 SSL session cache, so all other requests are just as fast as with other certificate lengths. For a quick response even on the first access, we recom- mend RSA 2048-bit certificates that offer adequate security, too. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 64: Console

    1 http server set https_both http server set 0 Numerical parameters can be entered with different bases. Here is an example of the decimal value 11: Base Input Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 65 If you use a tool to send an entire file of commands via Telnet, it is helpful, if you can place comments in there. Beginning with the comment character "#", the remaining con- Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 66 The command lists one connected external sensor per line, and the individual measured values are separated by commas after the label name. The digit before the equal sign corresponds to the Index field in the External Sensor Table. >extsensor 1 0 value show Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 67 3 possible formats. e) Switching Port Relays #port all state set "1,2,12" 1 The command syntax "port all state set "{port_list}" {OFF=0|ON=1}" sets a list of ports Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 68: Ssh

    256, 384 Generation with PuTTYgen Generated keys can be copied directly from e.g. PuTTYgen, and inserted into the Configuration - Console input field. Public keys are accepted in SSH2 or OpenSSH format. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 69: Console Cmd 7213

    {OFF=0|ON=1} enables delay (after 3 login fails) on/off console telnet login delay show show s if login delay enabled console telnet pushmsgs config set {OFF=0| enables persistent push msgs Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 70 {off=0|on=1} extsensor {port_num} {sen_type} {sen_field} show s if sensor events are enabled events show extsensor {port_num} {sen_type} {sen_field} events type set enables different event types "{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 71 "{passw d}" sets hashed http admin passw ord enters cmd group "ip4" ip4 hostname set "{name}" sets device hostname ip4 hostname show show s device hostname Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 72 {broker_idx} keepalive set {num_secs} sets keep-alive time mqtt {broker_idx} keepalive show show s keep-alive time mqtt {broker_idx} topic set "{name}" sets topic prefix mqtt {broker_idx} topic show shw os topic prefix Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 73 SHA1=2|SHA256=3|SHA384=4|SHA512=5} snmp snmpv3 authalg show show SNMP v3 authentication algorithm snmp snmpv3 privalg set {NONE=0|DES=1| 3DES=2|AES128=3|AES192=4|AES256=5| sets SNMP v3 privacy algorithm AES192*=6|AES256*=7} snmp snmpv3 privalg show show SNMP v3 privacy algorithm Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 74 {rule_num} action hash set "{data}" sets action binary form timer {rule_num} action hash show show s action binary form timer {rule_num} delete delete one timer timer delete all delete all timer Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 75: Console Cmd 7214

    "clock" clock ntp enabled set {OFF=0|ON=1} enables ntp clock ntp enabled show show s if ntp enabled clock timezone set {minutes} sets timezone Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 76 SMTP port email security set {NONE=0|STARTTLS=1|SSL=2} sets SMTP connection security email security show show s SMTP connection security email auth set {NONE=0|PLAIN=1|LOGIN=2} sets email authentication Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 77 {port_num} {sen_type} {sen_field} sets publish delta value publish delta set {float} extsensor {port_num} {sen_type} {sen_field} show s publish delta value publish delta show Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 78 {port_num} {LOW=0|HIGH=1} state set sets Port state for Pow er Port Sw itching actions {OFF=0|ON=1|DISABLED=2} show s Port state for Pow er Port Sw itching input {port_num} {LOW=0|HIGH=1} state show actions Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 79 {broker_idx} user show show s username mqtt {broker_idx} passw d set "{passw d}" sets passw ord mqtt {broker_idx} passw d hash set "{passw d}" sets hashed passw d Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 80 {OFF=0|ON=1} port {port_num} w atchdog retrybooting show show s port w atchdog retry booting state port {port_num} w atchdog bootretries set {num} sets port w atchdog retry boot timeout Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 81 "{passw d}" sets SNMP v3 authentication hashed passw ord snmp snmpv3 privpassw d hash set "{passw d}" sets SNMP v3 privacy hashed passw ord snmp trap type set {NONE=0|V1=1|V2=2|V3=3} sets type of SNMP traps Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 82 {rule_num} action {SWITCH1=0|SWITCH2=1} sets port list for sw itch cmd {OFF=0|ON=1} set "{port_list}" timer {rule_num} action {SWITCH1=0|SWITCH2=1} show s port list for sw itch cmd {OFF=0|ON=1} show Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 83: Modbus Tcp

    Temperature °C Humidity Digital Input bool Air Pressure Dew Point °C Dew Point Temperature Difference °C Modbus TCP Important: All calculations in this chapter are based on addresses starting at "0". Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 84 Write Single Coil 0x05 Write Multiple Coils 0x0f Read Input Registers 0x04 Read Holding Registers 0x03 Write Holding Register 0x06 Write Multiple Holding Registers 0x10 Read Device Identification 0x2B / 0x0E Coils Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 85 Number of Ports (Relay) 16-bit Number of Ports (Outlets) with Energy Measurement 16-bit Number of Banks 16-bit Number of Line-In 16-bit Phases per line 16-bit Number of Inputs Sensor Type Description Address Width Information Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 86 0x100 + Port * 8 + Offset In the Expert Sensor Box 7213 / 7214 the internal sensor corresponds to the value Port = 0, and is coded Port = 1 for Sensor 2 and Port = 2 for Sensor 3.
  • Page 87 The measured values of the energy sensors are re- turned as signed 16-bit integers. The following formulas are available for the address (the values for Bank and PowerSrc start at zero): Bank: 0x8200 + Bank * 2 + Offset Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 88 0x000 0x00f Sets Power Source for Bank Fan Mode 0x010 0x01f 0 = Automatic / 1 = Maximum Device Identification Returns manufacturer name and device identification: Request Code 1 Byte 0x2b Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 89: Sensor Tables

    For the Expert Sensor Box 7213 / 7214, the internal sensor corresponds to the value Port = 0. There, Port = 1 for Sensor 2, and Port = 2 for Sensor 3.
  • Page 90 The JSON object "result" returns whether the command was valid. The object "id" in the command is optional and is passed through in the response from the device. The passed number can help to establish a synchronicity between command and response via the broker. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 91 "port": "3", "name": "Power Port", "state": 0 }, { "port": "4", "name": "Power Port", "state": 0 "line_in": [{ "voltage": 242.48, "current": 0.000 "sensors": [{ "idx": 1, "name": "7105", "data": [{ "field": "temperature", Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 92: Example Hivemq

    Create a free or commercial account at www.hivemq.com and create a new cluster. In the "Manage Clusters" section, go to "Access Management" and add an MQTT user with name and password. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 93 Specifications In the MQTT configuration of the Gude device, transfer the hostname of the HiveMQ broker, as well as username and password. Additionally activate TLS and set the correct port. Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 94: Support

    Support...
  • Page 95: Data Security

    · If possible, place the device behind a firewall. Contact GUDE Systems GmbH Von-der-Wettern-Straße 23 51149 Cologne Germany Phone: +49-221-912 90 97 Fax: +49-221-912 90 98 E-Mail: mail@gude.info Internet: www.gude.info shop.gude.info Managing Director: Dr.-Ing. Michael Gude Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 96: Declaration Of Conformity

    Value added tax identification number (VAT): DE 122778228 Declaration of Conformity This product from the Expert Sensor Box 7213 / 7214 series is in conformity with the European directives for CE marking applicable to this product. The complete CE declara- tion of conformity for this product can be found on the website www.gude.info in the...
  • Page 97 (e.g. from the Maintenance Page 9. Disable switching events · You can set the sending of syslog, emails etc. when switching ports (only concerns Gude devices with relays) under "System" in the sensor configuration Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 98: Index

    - S - - G - Security Advice Select button GBL_Conf.exe Sensors 10, 47 SNMP 34, 56 - H - Start-up the device HTTP Status LED HTTPS Status-LED syslog - I - Installation Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 99 Index - T - Technical Specifications Terminal Assignment Timer Timer Configuration - W - Watchdog Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...
  • Page 100 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH 3/16/2022 Expert Sensor Box 7213/7214 © 2022 GUDE Systems GmbH...

This manual is also suitable for:

Expert sensor box 7214

Table of Contents