– ensure that the firelighter is properly positioned;
– unplug the firelighter before removal from the fire;
– allow the firelighter to cool before storage;
– do not allow the hot parts of the firelighter to touch the cord or other
flammable materials.
COOLING:
Before turning off the device, it must be cooled first. Select temperature
setting I for at least one minute. The device can be switched off thereafter.
Place the appliance on its kickstand (3) after use and allow it to cool
down before storage
STORAGE:
Make sure that the device has completely cooled down before storing.
CLEANING︓
Keep the ventilation slots of the machine clean to prevent overheating of
the engine. Regularly clean the machine housing with a soft cloth, preferably
after each use. Keep the ventilation slots free from dust and dirt. If the dirt
does not come off use a soft cloth moistened with soapy water. Never use
solvents such as petrol, alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
TECHNICAL DATA︓
Voltage: ........................... 230 – 240 V~ 50 Hz
Power: ............................. 2000 W
Air flow: ............................ 500 litres/minute
Setting I: ........................... 50 °C
Setting II: .......................... 600 °C
www.chestergarden.be