Summary of Contents for ECOFER UVC09

  • Page 1 User’s Manual of Air-conditioners ECOFER UVC09 ECOFER UVC12 ECOFER UVC18 ECOFER UVC24 Please read this user’s manual carefully before operation and keep it for reference Ithomis Str. 6, Chalandri, GR-15231 Athens - Greece Τel: +30210 6715510 / +30211 7007269/ +30211 7007270...
  • Page 2: Table Of Contents

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Table of contents SAFETY INSTRUCTIONS ................................. 1 Symbol Description ................................1 Installation Instruction ..............................1 Operating Instruction ............................... 1 Safety Instruction ................................4 PRODUCT INTRODUCTION ..............................5 Protect Functions ................................5 UVC TECHNOLOGY ................................6 UVC working theory ................................. 6 58℃...
  • Page 3: Safety Instructions

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual SAFETY INSTRUCTIONS Symbol Description Warning: A symbol indicating operation which may cause personnel casualties or serious damages. Caution: A symbol indicating operation which may cause personnel casualties or property damages. Installation Instruction Warning: Never install by yourself.
  • Page 4 ECOFER UVC09/UVC12/UVC18/UVC24 User manual Electrical safety Grounding: This room air conditioner must be grounded. Grounding reduces the risk of electric shock by providing an escape wire for the electric current. If the power cord has a grounding plug with a grounding wire, plug it into an outlet that is properly installed and grounded.
  • Page 5 ECOFER UVC09/UVC12/UVC18/UVC24 User manual Energy Saving Guide • When installing your air conditioner make sure to seal all areas where there is a possibility of air leakage. • Airflow should not be blocked inside either by curtains, drapes or furniture or outside by shrubs or bushes.
  • Page 6: Safety Instruction

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Pull off power plug or switch off breaker if Do not substitute fuse with lead wire or the air conditioner is not used for a long other time. materials. Safety Instruction Warning: The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
  • Page 7: Product Introduction

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Do not place plants or animals directly in Please contact service agents for service. the path of the air conditioner’ s airflow. Improper service may cause accident. Doing so could harm them Switch off the unit, cut off the power...
  • Page 8: Uvc Technology

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Indoor fan will keep running at low fan speed for 80 seconds when air conditioner is stopped in heating mode. Cooling airflow proof In the first several minutes of heating operation, PAUSE indicator lights; indoor fan doesn’t run and louver blades cannot be controlled.
  • Page 9: Mildew Proof

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Mildew proof After the cooling or dehumidification mode is turned off, a large amount of water stains still remains in the evaporator and air duct of the internal unit. To prevent mildew, mold and breeding of germs, the air conditioner will continue to supply air for 3 minutes to dry residual moisture.
  • Page 10: Description Of Components

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual DESCRIPTION OF COMPONENTS View of unit Remarks: The air conditioner is consisting of indoor unit, outdoor unit and remote controller. The design and shape are different for different models. The above figures are only schematic, and they may be slightly different from the actual appliances you selected.
  • Page 11: Indicator Light

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Remarks: 1. Flashing of any indicator means the air conditioner runs abnormally, please contact thedistributor in time. 2. Function a: The air conditioner will only display “RUN” indicator to save electricity if it do not receive any signal from remote controller in 30 seconds.
  • Page 12: Remote Controller

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Remote controller *The function Horizontal Swing (H-SWEEP) is not available in this version. Remarks: 1. HEAT, AUTO function and display are not available for cooling-only type air conditioner. 2. If user want to make the room air cool or warm quickly, user can press “turbo” button in cooling or heating mode, air conditioner will run in power function.
  • Page 13: Remote Controller Display

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Remote controller display *The functions AUH and Horizontal Swing are not available in this version. Instruction for remote controller • The remote controller uses two AAA alkaline batteries under normal condition, the batteries last for about 6 months.
  • Page 14: Operating Method

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual OPERATING METHOD Emergency Run When the remote controller is missing or the batteries are run out, you can use the Emergency Button. Operation Method: Under the “OFF” condition, open the front board and press Emergency Button with the tip end of a ball-pen or the like and the Air conditioner will operate in “AUTO”...
  • Page 15: Sleep Operation

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Sleep Operation 1. When air conditioner is in on status, press “SLEEP” button to enter “SLEEP” mode, and will display on the remote controller. 2. Press “SLEEP” button again, will disappear on the remote controller, and the sleep (energy saving) function will be cancelled.
  • Page 16: Clean Air Filter

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual Clean Air Filter 1. Open the front panel. 2. Lift the protruding part, then pull it downward, remove the air filter. 3. Clean it with vacuum cleaner or water. If air filter is very dirty, please clean it with warm soapy water or mild detergent.
  • Page 17: Recommendations For Energy Saving

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual 4. Take out batteries from remote controller. Recommendations for Energy Saving Appropriate Temp Setting Avoid Direct Sunlight It is harmful to health if the room is too When it is cooling, please use curtain or cold.
  • Page 18: Troubleshooting

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual TROUBLESHOOTING Air Conditioner is in Error Checking before service. Phenomenon Checking Items 1. Check whether the power is disconnected. Air Conditioner Does 2. Check whether the breaker is switched on or the fuse is burnt. Not Operate at All 3.
  • Page 19: Normal Phenomena

    ECOFER UVC09/UVC12/UVC18/UVC24 User manual NORMAL PHENOMENA If the indoor humidity is too high, water When it is heating or cooling, plastic drops may form on the front grill of indoor substance may give out a sound because of unit. This is a normal the temperature change.
  • Page 20 ECOFER UVC09/UVC12/UVC18/UVC24 User manual...
  • Page 21 ECOFER UVC09/UVC12/UVC18/UVC24 User manual Ithomis Str. 6, Chalandri, GR-15231 Athens - Greece Τel: +30210 6715510 / +30211 7007269/ +30211 7007270 Fax: +302106542877 Website: www.ecofer.com.gr...

This manual is also suitable for:

Uvc12Uvc18Uvc24

Table of Contents