Page 1
S h o w i n g t h e W o r l d SDC015 Series HD PTZ Cameras User Manual V1.0...
Page 2
Make sure there are no objects within the rotation area of the camera. Never power on before installation is completed. Do not disassemble. We are not responsible for any unauthorized modification or dismantling. Attention Electromagnetic field under certain rates may affect camera image! Website: www.seada.co.uk 1 / 47 E-mail: sales@seada.co.uk...
2、Base 6、RS232 (IN) 10、10/100M LAN Port 3、Remote Controller Receiver Light 7、USB2.0 11、Power Supply 4、Bottom Dial Switch 8、USB3.0 Note: Different model has different interface. Users should read the manual according to the device model. Website: www.seada.co.uk 4 / 47 E-mail: sales@seada.co.uk...
USB2.0 video cable connection: U2U3HL models--No.7 in Figure1.2. b. Connect the camera and the PC via USB2.0 video cable, open video display software, select image device, and then video output will be available. Website: www.seada.co.uk 5 / 47 E-mail: sales@seada.co.uk...
Page 7
1.4 Bracket mount Note: Do not use Bracket on plasterboard. Bracket is optional and ordered separately 1) Wall mount steps Website: www.seada.co.uk 6 / 47 E-mail: sales@seada.co.uk...
Page 8
2. Upside down mount steps Website: www.seada.co.uk 7 / 47 E-mail: sales@seada.co.uk...
USB video signals. If using a power adapter, the general USB2.0 video cable without power supply function is ok. For consistent video quality always use the external Website: www.seada.co.uk 8 / 47...
Support compression of resolution up to 1920x1080 with frame up to 60 fps and 2 channel 1920x1080p with 30 fps compression. Multiple network protocol: Support ONVIF, RTSP, RTMP protocols and RTMP push mode, easy to link streaming media server (Wowza, FMS) Website: www.seada.co.uk 9 / 47 E-mail: sales@seada.co.uk...
255 presets (10 presets by remote controller) Other Parameter Supply Adapter AC110V-AC220V to DC12V/2A Input Voltage DC12V±10% Input Current 1A(Max) Consumption 12W (Max) Store Temperature -10℃ to +60℃ Store Humidity 20% - 95% Working Temperature -10℃ to +50℃ Website: www.seada.co.uk 10 / 47 E-mail: sales@seada.co.uk...
U2U3HL model: two DIP switches are set to ON or OFF to select different modes of operation as shown in Table 2.3 Table 2.3 Dial Switch setting Explanation Working Mode USB3.0 Software Upgrade Mode ARM Software Upgrade Mode Note: Working mode can be applicable for web upgrade. Website: www.seada.co.uk 11 / 47 E-mail: sales@seada.co.uk...
7.RTS 8.NC 8.CTS 9.RI 2) RS-232 Mini-DIN 8-pin Port Definition Port Definition Data Terminal Ready Data Set Ready Transmit Data System Ground Receive Data System Ground IR OUT IR Commander Signal No Connection Website: www.seada.co.uk 12 / 47 E-mail: sales@seada.co.uk...
Page 14
7.OPEN 8. NC 8.OPEN Note: SHLP/SHLPN model has RS232 input and output interface, so users can cascade multi devices together. It won’t work for U2U3HL model since it only has RS232 input interface. Website: www.seada.co.uk 13 / 47 E-mail: sales@seada.co.uk...
Device Manager to see whether there is an image device and whether the Universal Serial Bus controllers recognize USB3.0 device. After properly identified, open the software, choose the image device and then it will output image. Website: www.seada.co.uk 14 / 47...
13)【#】+【#】+【5】: Switch the video format to 720P50 14)【#】+【#】+【6】: Switch the video format to 1080P30 15)【#】+【#】+【7】: Switch the video format to 1080P25 16)【#】+【#】+【8】: Switch the video format to 720P30 17)【#】+【#】+【9】: Switch the video format to 720P25 Website: www.seada.co.uk 15 / 47 E-mail: sales@seada.co.uk...
Auto Focus: Support Manual Focus: Support Press and hold the key, the action of focus will keep continue and stops as soon as the key is released. 5) BLC Setting BLC ON / OFF: support Website: www.seada.co.uk 16 / 47 E-mail: sales@seada.co.uk...
English (Setup) (Camera) (P/T/Z) (Video Format) (Version) (Restore Default) [ ↑ ↓ ]Select [ ← → ]Change Value [Menu]Back [Home]OK LANGUAGE: Language setting, Chinese / English SETUP: System setting CAMERA OPTION: Camera setting Website: www.seada.co.uk 17 / 47 E-mail: sales@seada.co.uk...
CAMERA =============== (Exposure) (Color) (Image) (Focus) (Noise Reduction) [↑↓]Select [← →]Change Value EXPOSURE: Enter Exposure setting COLOR: Enter color setting Image: Enter image settings Focus: Enter focus settings Noise Reduction: Enter noise reduction Website: www.seada.co.uk 18 / 47 E-mail: sales@seada.co.uk...
Page 20
Move the pointer to the (COLOR) in the Main Menu, click the【HOME】and enter the (COLOR SET) as follow, COLOR =============== WB Mode Auto Saturation AWB Sensitivity High Color style Default Color temp [ ↑ ↓ ]Select [ ← → ]Change Value [Menu]Back 3000K、3500K、4000K、4500K、5000K、5500K、6000K、6500K、7000K WB Mode: Auto, , Manual, One Push Website: www.seada.co.uk 19 / 47 E-mail: sales@seada.co.uk...
Page 21
Move the pointer to the (FOCUS) in the Menu, click the【HOME】and enter the (FOCUS) as follow, FOCUS ================ Focus Mode Auto AF-Zone Center AF-Sensitivity [↑↓]Select [← →]Change Value [Menu]Back Focus Mode: Auto, manual AF-Zone: Up, middle, down AF-Sensitivity: High, middle, low Website: www.seada.co.uk 20 / 47 E-mail: sales@seada.co.uk...
Depth of Field: Only effective for remote controller, On/ Off. When zoom in, the PT control speed by remoter will become slow), Zoom Speed: Set the zoom speed for remote controller,1~8 Image Freezing: On/Off Accelerating Curve: Fast/slow Website: www.seada.co.uk 21 / 47 E-mail: sales@seada.co.uk...
Camera Version 2.0.0.13 2015-12-18 AF Version 2.0.0.6 2015-12-11 Lens 12X(20X) [Menu]Back MCU Version: Display MCU version information Camera Version: Display camera version information AF Version: Display the focus version information Lens: Display the lens zoom Website: www.seada.co.uk 22 / 47 E-mail: sales@seada.co.uk...
Note: If the address of former remoter is not 1 but another one from 2,3,4, the corresponding camera address will restore to 1 when all parameters or system parameters are restored. User should change the remoter address to be 1 (press No.1 according to the camera so to get normal operation) Website: www.seada.co.uk 23 / 47 E-mail: sales@seada.co.uk...
IP address of the camera. Note: The IP address to be added cannot be same with that of other computers or devices. The existence of this IP address needs to be verified before adding. Website: www.seada.co.uk 24 / 47 E-mail: sales@seada.co.uk...
Default Username, password: admin PTZ control can be carried out, zoom, focus, video capture, sound, zoom, full screen and set the preset position, run, and delete; you can preview, configuration and log off. Website: www.seada.co.uk 25 / 47 E-mail: sales@seada.co.uk...
Input Volume: Set the input audio volume (Default 4, ranges from 1~10) Note, click “SAVE”, it will pop up “Enable has changed. Restart the device to take effect after the success of the save.”, then please reboot the camera to make new setting effect. Website: www.seada.co.uk 26 / 47 E-mail: sales@seada.co.uk...
Frame Min QP: Set the minimum QP of the key frame (Default 10, ranges from 10~51) Stream Name: When streaming via RTSP or RTMP, user can modify stream name: Main stream(live/av0), Sub stream(live/av1). Click the "Save" button to display the "saved successfully" message, then settings take effect. Website: www.seada.co.uk 27 / 47 E-mail: sales@seada.co.uk...
Page 29
Click on the "Save" button to display the pop up "Save successful" message, which ensures setting have been set. Method of obtaining RTSP: rtsp: // device IP address: 554 / live / av0 (av0 Main stream; av1 Sub stream) Website: www.seada.co.uk 28 / 47...
Page 30
Shutter: active when it is status of manual or shutter-priority (default 1/100,1/25、1/30、1/50、1/60、1/90、1/100、 1/120、1/180、1/250、1/350、1/500、1/1000、1/2000、1/3000、1/4000、1/6000、1/10000 optional). C: Color: WB Mode: Set the white balance mode (the default automatic,3000K,4000K,5000K,6500K, manual, One-push optional). Note: Click the “Correction” button when selected the One-push white balance mode. Website: www.seada.co.uk 29 / 47 E-mail: sales@seada.co.uk...
Page 31
Title Content: Set title content (default CAMERA1). Time Content: Set time content (default 1970/01/10 05:36:00) Click on the "Save" button and display the "Save successful" message, then valid. Website: www.seada.co.uk 30 / 47 E-mail: sales@seada.co.uk...
Page 32
Click on the "Save" button to display "Parameter saved successfully" message, set to take effect. 7) Video output Video Out Format: Set the video output format (default 1080P60,1080P50,1080P30,1080P25,1080I60,1080I50,720P60,720P50,720P30,720P25,1080P59.94,1080I59.94,1080P 29.97,720P59.94,720P29.97 optional). Click on the "Save" button, it will be valid when display "Save successful". Website: www.seada.co.uk 31 / 47 E-mail: sales@seada.co.uk...
Click on the "Save" button, it will be valid when display "Save successful". RTMP access: RTMP: / / equipment IP address: 1935 / live/av0 (av0 mainstream; av1 second stream) RTMP Access:rtmp://equipment IP address: 1935 / live/av0 (av0 mainstream; av1 second stream) Website: www.seada.co.uk 32 / 47 E-mail: sales@seada.co.uk...
Page 34
3) DNS Preferred DNS server: set the preferred DNS server. (Default 0.0.0.0). Alternate DNS server: Alternate DNS server settings. (Default 0.0.0.0). Click on the "Save" button, it will be valid when display "Save successful". Website: www.seada.co.uk 33 / 47 E-mail: sales@seada.co.uk...
Page 35
Heartbeat time (seconds): 60 Range 1-65535 Register ID: 34020000001320000001 Register Name: IPC Register Password: 12345678 Equipment Belong: Users can add their own Administrative Regions: Users can add their own Alarm Areas: Users can add their own Website: www.seada.co.uk 34 / 47 E-mail: sales@seada.co.uk...
Device ID: Set the device ID (default 1, Read-Only). Language: Set the system language, Need to re-login after modifying and saving the setting. Click on the "Save" button, it will be valid when display "Save successful". Website: www.seada.co.uk 35 / 47 E-mail: sales@seada.co.uk...
Page 37
Time setting: Set time mode (to choose the computer time synchronization, NTP server time synchronization, or set manually). Computer Time: Set the computer synchronization valid. Click on the "Save" button, it will be valid when display "Save successful". Website: www.seada.co.uk 36 / 47 E-mail: sales@seada.co.uk...
Page 38
Click on pop-up "Restore Factory Defaults" button and choose “yes” or “no”, then the device will restart automatically and restore factory setting. 6) Reboot Click on the pop-up "Reboot" button and choose “yes” or “no”, then the device will restart automatically Website: www.seada.co.uk 37 / 47 E-mail: sales@seada.co.uk...
4.2.8 Logout Point "Logout" pop-up "Confirmation" dialog; select "Yes" or "No”, choose “Yes” to exit the current page and return to the user login interface again. Website: www.seada.co.uk 38 / 47 E-mail: sales@seada.co.uk...
D: Click "Start" and select "Run" and then type “cmd” in the computer; Click "OK" then turn on a DOS command window to enter ping 192.168.5.163. Press the Enter key to appear message as follows: Description network connection is normal Website: www.seada.co.uk 46 / 47 E-mail: sales@seada.co.uk...
Page 48
Copyright Notice: All the contents of this manual and the copyright ownership belong to SEADA. Without the approval of SEADA, no one can imitate, copy, reproduce or translate arbitrarily. This manual does not have any form of warranty, express or other imply.
Need help?
Do you have a question about the SDC015 Series and is the answer not in the manual?