Page 21
Instruction Manual Pulse Ion Bar SH Series SH-16 / 20 / 30 / 40 / 50 / 60 / 70 / G3 Thank you for purchasing our Stat Clean No. SH series. Read this instruction manual before use. Keep it in a safe handy place for future reference. Table of Contents ■For Your Safety ·······················...
For Your Safety Safety Precautions ・ Please read this manual thoroughly before starting use. ・ Utilize this manual responsibly so that all operators are aware of safety issues. ・ Store this manual nearby where it can be accessed easily. The precautions given in this manual are categorized into the following two types according to the degree of danger.
Product Overview ■ Shape ・ High voltage power supply standalone, compact type This compact model can be installed easily in small devices. ■ Performance ・ Pulse AC method The static eraser uses the pulse AC corona discharge method to generate positive ions and negative ions from individual electrodes.
Page 24
Product Overview Bar specifications Model : No. SH-16, SH-20, SH-30, SH-40, SH-50, SH-60, SH-70 Ion generation method : Pulse AC corona discharge method Applied voltage : 10.5 kV (p-p) Frequency : 30 Hz Pulse ratio : 40 to 70% on positive side, 60 to 30% on negative side (adjustable with SH-G3) Air connection Hose: outer diameter Φ6 mm ×...
Page 25
Product Overview Performance table Measurement model: SH-40 Air pressure: 0.1, 0.3 MPa Decay time: ± 1000 V to ± 100 V CPM: Trek 158 (20 pF 150 mm2 ) Temperature: 25 ± 5 °C Humidity: 50 ± 5 %...
Various Functions Various Functions Fully comprehend each component and function to ensure safe operation and safe work. SH-16, SH-20, SH-30, SH-40, SH-50, SH-60, SH-70 This is the connection port for the outer diameter 6 mm × inner Air supply port ①...
Page 32
Various Functions SH-G3 This is the high-voltage power output socket to which the High-voltage output socket ① power cable is connected. Grounding terminal This is the grounding connection point. ② Power supply port This is the 100 VAC to 240 VAC power supply port. ③...
Installation Installation WARNING Do not use the eraser in the following places. There is a risk of explosion or fire. PROHIBITED * Where explosion-proofing is required * Where corrosive gases, flammable or explosive gases are handled" CAUTIONS Consider the surrounding environment when choosing the installation location. * Install the eraser indoors where it is not subject to wind, rain or direct sunlight.
Page 34
Installation Installation distance and cable length CAUTIONS Always attach the enclosed cap to any idle high-voltage output sockets. REMEMBER Entry of dust into the high-voltage output socket can result in failure." The power cable supplies a high-voltage. REMEMBER Make sure it does not bend excessively and break or deform from pulling. Cable length Plan the length of the power cable from the power supply unit (SH-G3) based on the following configuration drawing.
Page 35
Installation Wiring the power supply CAUTIONS Always stop the power supply before starting wiring work to prevent electric REMEMBER shock. Always follow Electrical Facility Technical Standards and any other supplemental REMEMBER regulations when wiring to prevent electric leak, electric shock or fire. Provide sufficient allowance to the cable when wiring so that the AC cord and REMEMBER power cable do not bend and break.
Installation Air piping CAUTIONS Always use a pressure-resistant air hose. REMEMBER Failure to use a pressure-resistant air hose could result in ruptures or air leaks. Applicable air / nitrogen This eraser requires clean compressed air (CDA) or N2 gas for air blow operation. Supply air within the pressure range of 0 to 0.5 MPa.
Operation Adjusting the pulse ratio "The SH-G3 pulse ratio is set to the optimum position before shipment. Adjust the SH-G3 pulse ratio to match your working environment and distance. Always use an ANSI EOS/ESD S3.1 compliant charge plate monitor when adjusting the pulse ratio. (Adjustable range...
Storage Storage CAUTIONS Do not store the eraser in the following types of places. There is a risk of failure. * Where the eraser could be subject to strong vibration or shock * Where the temperature or humidity exceeds the specified range * Where dew condenses PROHIBITED * Where the temperature fluctuates suddenly...
Removal Removal Always secure the safety of the surrounding area and workers before removing the eraser. CAUTIONS Before removing the eraser, always disconnect the AC cord plug from the UNPLUG socket to prevent accidents from electric shocks or from incorrect operations. Always confirm that the air source has been turned off before disconnecting the air hose.
Defective products must be returned to VESSEL Osaka Japan with proof of purchase date. And if your unit is out of warranty, VESSEL will quote repair charges necessary to ship your unit freight prepaid to where you have originally purchased.
Need help?
Do you have a question about the Stat-Clean SH Series and is the answer not in the manual?
Questions and answers