Troubleshooting - Heinner VGEN002 Instructions Manual

Table of Contents

Advertisement

8.TROUBLESHOOTING
The engine does not start:
Is there fuel in the tank?
YES
Is there engine switch on?
YES
Is the fuel valve on?
YES
Is there enough oil in the engine?
YES
Is there a spark from the spark plug?
WARNING! Be sure there is no spilled
fuel around the spark plug. Spilled fuel
may ignite.
YES
Is the fuel reaching the carburetor?
YES
If the engine still does not start, take the
generator to an authorized dealer.
NO
NO
NO
NO
(The oil alert lamp goes on when pulling
the start grip.)
NO
Replace the spark
plug.
To check:
1) Remove the spark plug cap and clean
any dirt from around the spark plug.
2) Remove the spark plug and install the
spark plug in the plug cap.
3) Set the plug side electrode on the
cylinder head.
4) Pull the recoil starter, spark should
jump across the gap.
NO
To check:
1) Turn on the fuel valve and remove the
drain screw.
2) Fuel should flow from the drain when
the fuel valve is turned on.
GASOLINE GENERATOR
Refill the fuel tank.
Turn the engine switch on.
Turn the fuel valve on.
Add the recommended oil
Take the generator to an authorized
dealer.
Clean the fuel filter cup.
11

Advertisement

Table of Contents
loading

Table of Contents