Solar Powered Photo Eyes
Wall-mounted encoding photo eyes with Transmitter operated by solar panel and re-chargeable battery, with 180°
rotation and range of up to 35 feet.
The iGAZES035 Solar photo eye solves problems related to installing electrical cables to connect the transmitter
and receiver. It is also possible to install 2 pairs of the same model without any interference between them if they
are encoded accordingly at the time of installation.
T T
: :
E E C C H H N N I I C C A A L L D D A A T T A A
- Max. range
- TX power supply
- RX power supply
- TX absorption
- RX absorption
- Relay contact rating
- Operating temperature
- Container
- Protection rating
- Container dimensions
D D
E E S S C C R R I I P P T T I I O O N N O O F F T T H H E E
P P o o w w e e r r s s u u p p p p l l y y and operation:
The transmitter is powered by a solar panel mounted on the cover and a 1.2 Volt re -chargeable battery that allows
it to operate in the absence of light.
S S e e l l e e c c t t i i n n g g t t h h e e O O p p e e r r a a t t i i n n g g R R a a n n g g e e ( ( S S W W 1 1 D D i i p p S S w w i i t t c c h h N N o o . . 1 1 ) ) : :
The maximum distance of operation of the battery-operated photo eye is approximately 35 feet (10 meters) at normal
power (Dip Switch No. 1 OFF "factory configuration") and approximately 65 feet (20 meters) at maximum power
(Dip Switch No. 1 ON).
S S e e l l e e c c t t i i n n g g O O p p e e r r a a t t i i n n g g C C o o d d e e " " A A " " a a n n d d " " B B " " ( ( S S W W 1 1 D D i i p p S S w w i i t t c c h h N N o o . . 2 2 ) ) : :
The photo eye has two operating encoding channels "A" and "B", in this way it is possible to install 2 pairs of the
same model without any interference between them. Code "A" ( Dip Switch No. 2 OFF "factory configuration" ) or
code "B" ( Dip Switch No. 2 ON ), must be accordingly selected in the same way, at the time of installation, on
both the transmitter and receiver.
I I m m p p o o r r t t a a n n t t : :
It is possible to connect a "N.C." safety device to the transmitter (for example a
safety edge mounted on the leading edge of a sliding gate): when the contact
opens the transmitter stops transmitting.
If no "N.C." safety device is used (eg. safety edge),
inputs 3 and 4 must always be jumpered.
C C o o n n n n e e c c t t i i o o n n s s : :
1 - Connection for red wire ( + ) Solar Panel.
2 - Connection for black wire ( - ) Solar Panel.
3 - "N.C." safety device (Jumper only if not used)
4 - "N.C." safety device (Jumper only if not used)
: 35 feet
: 1 1.2V Re -chargeable AA battery
: 12 -24 VAC/DC
: 0.30 mA Max.
: 25 mA Max.
: 1A max at 30 VDC
: -4˚F to 131˚F
: Polycarbonate
: NEMA 4 X(IP 54)
: 1 x 3 x 1 inches
2
3
5
3
T T
( ( T T X X ) ) : :
R R A A N N S S M M I I T T T T E E R R
4
5
ON
1
2
CN1
ON
1
2
JUMPER