AFRISO DMU 10 D Operating Instructions Manual

Differential pressure transmitter

Advertisement

Quick Links

Operating instrucions
Differential pressure transmitter
Version: 10.2021.0
ID: 900.100.0865
Copyright 2021 AFRISO-EURO-INDEX GmbH. All rights reserved.
DMU 10 D
DMU 11 D
DMU 10 D
DMU 11 D
Lindenstraße 20
74363 Güglingen
Telefon +49 7135 102-0
Service +49 7135 102-211
Telefax +49 7135 102-147
info@afriso.com
www.afriso.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DMU 10 D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AFRISO DMU 10 D

  • Page 1 Operating instrucions DMU 10 D DMU 11 D Differential pressure transmitter DMU 10 D DMU 11 D Copyright 2021 AFRISO-EURO-INDEX GmbH. All rights reserved. Lindenstraße 20 74363 Güglingen Telefon +49 7135 102-0 Service +49 7135 102-211 Telefax +49 7135 102-147 Version: 10.2021.0...
  • Page 2: Target Group

    The compact design allows a simple integration even in constructions and machines with restricted space conditions. • Base elements of DMU 10 D are 2 piezoresistive stainless steel sensors. DMU 11 D is based on a piezoresistive silicon pressure sensor.
  • Page 3: Product Identification

    • For the connection of the pressure lines, a sealing has to be installed by the operator. • For the pipe assembly, an installation as zero-potential as possible must be observed. • Consider for the installation of a DMU 10 D, that the pressure ports must not be turned against the housing! 3.2 General installation steps...
  • Page 4: Electrical Connection

    Fig. 2 Mounting possibilities 3.3 Installation steps for DMU 10 D with G 1/8" internal thread • Check to ensure that the O-rings fit properly into the grooves. (O-rings are not included in the scope of delivery.) •...
  • Page 5 Please check if the delivered seal is placed between plug and cable socket. Fasten the cable socket on the device by using the screw, after connecting the cable. Pin configuration: DMU 10 D DMU 11 D Electrical connection ISO 4400...
  • Page 6: Troubleshooting

    4. Commissioning Please note that for starting up, the device has to be stressed by pressure simultaneously at both pressure ports. Otherwise the sensor could be damaged. For one-sided pressure admission, the permissible static pressure (one-sided) must be attended. Please take this out of the current data sheet.
  • Page 7: Maintenance

    1. Disconnect the product from mains. 2. Dismount the product (see chapter "Mounting", reverse sequence of steps). 3. Dispose of the product. 11. Warranty See our terms and conditions at www.afriso.com or your purchase contract for information on warranty.
  • Page 8: 12. Eu Declaration Of Conformity

    12. EU Declaration of Conformity...