WEEKLY TESTING
• Test Alarm – use to test the Smoke/Heat Alarms remotely.
1. Press the Test Alarm switch
Now check all the alarms sound and the red lights
on the covers flash rapidly. Then turn off the Test
Alarm switch.
This is equivalent to pressing the test button on all
alarms simultaneously.
It also checks that the remote control is receiving
mains power.
2. If the alarms do not sound
Check for the green mains light on the front cover
of the alarms.
If all alarms do not have the green mains light on,
check fuses, circuit breakers etc. (see Smoke/Heat
Alarm instructions for further details).
FIVE YEAR GUARANTEE
Ei Electronics guarantees this product for five years from date of purchase against any defects that are
due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and
service, and does not include damage resulting from accident, neglect, misuse, unauthorised
dismantling, or contamination howsoever caused. This guarantee excludes incidental and
consequential damage. If this product should become defective within the guarantee period, it must be
returned, with proof of purchase, carefully packaged, with the problem clearly stated (see addresses
below). We shall at our discretion repair or replace the faulty unit. Do not interfere with the product or
attempt to tamper with it. This will invalidate the guarantee, but more importantly may expose the user
to shock or fire hazards. This guarantee is in addition to your statutory rights as a consumer.
The crossed out wheelie bin symbol that is on your
product indicates that this product should not be disposed
of via the normal household waste stream. Proper
disposal will prevent possible harm to the environment or
to human health. When disposing of this product please
separate it from other waste streams to ensure that it can
be recycled in an environmentally sound manner. For
more details on collection and proper disposal, please
contact your local government office or the retailer where
you purchased this product.
17/8/10
9:42 AM
Page 1
Aico Ltd. Mile End Business Park,
Maesbury Rd, Oswestry,
Shropshire SY10 8NN, U.K
Tel: 0870 758 4000
www.aico.co.uk
Ei Electronics. Shannon, Ireland.
Tel: +353 (0)61 471277
www.eielectronics.com
4
REMOTE CONTROL
SWITCH
INSTRUCTIONS
WARNING: For use only with the following models:
Smoke/Heat/CO Alarms - 2100 Series, 160RC Series, Ei261ENRC & Ei261DENRC
Accessories - Ei128RBU, Ei169/160, MCP401RC
DO NOT use any other models with this remote control
The Remote Control is recommended for use in
Fire Alarms
systems
Control Switch
interconnected Alarms.
The Remote Control should be wall mounted at
standard light switch level (1.2m from floor
level) to allow easy access.
Locate
Test
Silence
Alarm
Alarm
Alarm
LOCATE ALARM:
If alarms sound, press to allow the source of alarm to be
identified audibly.
Press to silence nuisance alarms.
SILENCE ALARM:
Operate weekly to test the alarms. Can also be used to
TEST ALARM:
give a manual alarm
TheTest Alarm switch will not sound the alarms in the
MAINS CHECK:
absence of mains power.
SITING
Position the Remote Control in a location that will allow it
to be easily accessed. In the majority of installations this
will be in a hallway, possibly next to the master bedroom.
It should be installed at the standard light switch height
Bedroom
Landing
Bedroom
(1.2m from floor level).
The Remote Control can be surface mounted using the
mounting box provided or alternatively it can be
Hallway
recessed into a standard back-box (not included).
If a metal back-box is used it must have a minimum depth of 35mm.
Up to four Ei1529RC System Remote Controls can be used in a system.
© Ei Electronics 2010
1
Model
Ei1529RC
comprising
of
three
or
more
P/N B16112 Rev1

Advertisement

loading

Summary of Contents for Ei Electronics Ei1529RC

  • Page 1 TheTest Alarm switch will not sound the alarms in the MAINS CHECK: Ei Electronics guarantees this product for five years from date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and absence of mains power.
  • Page 2 If it is necessary to check insulation, temporarily 1. Disconnect the AC mains power supply from the circuit that is going to be remove all Alarms and the Ei1529RC switch. used to power the Smoke/Heat Alarms and the Remote Control.