Desa SF20NT Safety Information And Installation Manual page 13

Unvented (vent-free) solar fusion gas heater
Table of Contents

Advertisement

Available languages

Available languages

116307-01A
burner. Note: You may be running this
heater for the first time after hooking up to
gas supply. If so, you may need to press in
control knob for 30 seconds or more. This
will allow air to bleed from the gas system.
If needed, keep pressing ignitor button until
pilot lights. If ignitor does not light pilot,
refer to Troubleshooting, page 16 or contact
a qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 14.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop up when
released, contact a qualified service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4 thru 7.
Thermostat models have a safety interlock
system. Wait one (1) minute before lighting
pilot again.
9. Turn control knob counterclockwise
to desired heating level. The main burner
should light.
just heating levels by using the
equipment shutoff valve.
Ignitor Button
(Actual Ignitor may vary)
Figure 16 - Control Knob In The OFF
www.desatech.com
CAUTION: Do not try to ad-
Position
Control Knob
13