Sharp AR-5132 Service Manual page 43

Hide thumbs Also See for AR-5132:
Table of Contents

Advertisement

B. Adjust any center misalignment.
No adjustment should be needed for the unit as it is factory-set.
However, if it is off-center, adjust it according to the following proce-
dure.
Make a copy. If it is off center as shown in fig. 1 or fig. 2, loosen the
two center adjuster mounting screws attached to the cassette and
adjust it following the prcedure below.
Center adjuster
Center adjuster mounting screws
[Note]
When mounting the center adjuster, make sure that the mounting
screws are positioned in the same spot in their respective slots.
When off center as shown in fig. 1
Move the center adjuster in direction A and secure it with the two
mounting screws. Make a copy to check whether it is centered
properly.
Fig. 1
Center line of the first copy image
When off center as shown in fig. 2
Move the center adjuster in direction B and secure it with the two
mounting screws. Make a copy to check whether it is centered proer-
ly.
Fig. 2
Center line of the first copy image
Direction A
Direction B
Paper center line
Paper center line
(10) Copy density check
After installing the copier, check the copy density. If the density is not
in the specified range, adjust it.
(Refer to the print quality adjustment.)
(11) Installing sorter (SF-S53N)
<option>
Included parts
Caster screws
(M4 x 60): 8
Sorter mounting plate screws
(M4 x 12): 2
Bracket screws
(M4 x 10): 2
Sorter mounting plate: 1
Rail mounting plate: 1
5 – 15
Rail screws A
(M4 x 6): 2
Rail screws B
(M4 x 6): 1
Rail mounting plate screws
(M4 x 14): 2
Caster spacers: 4
Rail: 1

Advertisement

Table of Contents