INSTALLATION
OPERATION
MAINTENANCE
ALL phases of this installation must comply with
NATIONAL, STATE AND LOCAL CODES
Model:
TCK024B1
TCK030B1
TCK036B1
TCK042B1
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.
WARNING:
Warnings and Cautions appear at appropriate locations throughout this manual.
WARNING:
result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury. It may also be used to alert against unsafe practices
and where property-damage-only accidents could occur.
© 2009 Trane
HAZARDOUS VOLTAGE- DISCONNECT POWER and DISCHARGE
NOTICE
Read these carefully.
Indicates a potentially hazardous situation which, if not avoided, could
Single Packaged Cooling
2, 2 1/2, 3, 3 1/2 Ton
CAPACITORS BEFORE SERVICING
TCK-IOM-9
18-AB33D10-9
4/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCK024B1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trane TCK024B1

  • Page 1 ▲ CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices and where property-damage-only accidents could occur. © 2009 Trane 4/09...
  • Page 2: General Information

    GENERAL INFORMATION IMPORTANT: Read this entire manual before beginning instal- Read this manual carefully before attempting to install, operate, or lation procedures. perform maintenance on this unit. Installation and maintenance should be performed by qualified service technicians only. SAFETY NOTICE. THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSESSING ADEQUATE BACK- GROUNDS OF ELECTRICAL AND MECHANICAL EXPERI- INSPECTION...
  • Page 3: Installation

    INSTALLATION GROUND LEVEL -- HORIZONTAL UNITS UNIT SUPPORT For ground level installations, the unit should be positioned on a pad If unit is to be roof mounted, check building codes for weight the size of the unit or larger. The unit must be level on the pad. The distribution requirements.
  • Page 4: Unit Dimensions And Clearances

    30.80 (68) 134.70 (297) 441 (17-3/8) 413 (16-1/8) TCK030B1 30.80 (68) 38.60 (85) 34.90 (77) 28.10 (62) 131.90 (291) 302 (11-7/8) 413 (16-1/8) TCK024B1 34.01 (75) 34.01 (75) 31.29 (69) 31.29 (69) 131.18 (287) 302 (11-7/8) 413 (16-1/8) Page 4...
  • Page 5: Filter Installation

    FILTER INSTALLATION AIR FILTERS TABLE 1 Filters are to be used with the TCK024-42B heating/cooling units. NOMINAL FILTER* FILTER UNIT The basic unit does not have filters in it. (Sq Ft) SIZE RESISTANCE TCK024B 2.67 0.05 A filter rack must be installed by the installer in the duct work. TCK030B 1000 3.33...
  • Page 6 ELECTRICAL WIRING After all electrical wiring is complete, set the thermostat system the Thermostat System Switch until power has been applied long switch in the OFF position so that the compressor will not run enough to evaporate any liquid R-22 in the compressor. It is and then apply power by closing the system main disconnect recommended that the sump heater be energized for eight (8) hours switch.
  • Page 7 START - UP PRE-START QUICK CHECKLIST automatically. OPERATING PRESSURES ● Is the unit properly located and level with the proper clearance? See Figure 2. After the unit has operated in the cooling mode for a short period of time, install pressure gauges on the gauge ports of the discharge ●...
  • Page 8: Sequence Of Operation

    SEQUENCE OF OPERATION GENERAL starts with power from the control transformer and then energizes and motor speed tap terminal the fan relay coil (F) Operation of the system cooling and heating cycles is controlled by . This closes the fan relay (F) contacts and the indoor fan motor (IDM) the position of the system switch on the room thermostat.
  • Page 9: Maintenance

    MAINTENANCE ROUTINE MAINTENANCE BY OWNER MAINTENANCE PERFORMED BY SERVICEMAN -- HEATING SEASON You can do some of the periodic maintenance functions for your TCK-A unit yourself; this includes replacing the disposable or Complete the unit inspections and service routines described below cleaning the permanent air filters, cleaning the unit cabinet, clearing at the beginning of each heating season.
  • Page 10 Base Limited Warranty Packaged Air Conditioner and Packaged Heat Pump TCK, TCH, WCK, WCH (Parts Only) Models Less Than 20 Tons for Residential Use* This limited warranty is provided by the manufacturer to the original purchaser and to any succeeding owner of the real property to which the Packaged Air Conditioner or Packaged Heat Pump (packaged unit) is originally affixed, and applies to products purchased and retained for use within the U.S.A.
  • Page 11 Residential Systems 6200 Troup Highway, Tyler, TX 75707 Attention: Consumer Relations Or visit our website: www.trane.com/residential TW-1001-3308 * This warranty is for commercial usage of said equipment and not applicable when the equipment is used for a residential application. Commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes.
  • Page 12 Be sure the main switch that supplies power to the unit is in the ON position. Replace any burned-out fuses or reset circuit breakers. Be sure the thermostat is properly set. Service Phone_________________________________________________________________ Trane 6200 Troup Highway The manufacturer has a policy of continuous product and product data improvement,and Tyler,TX 75703 it reserves the right to change design and specification without notice.