The Model RF-2011 Automatic Drain is designed to automatically drain your compressor tank at specified intervals. If provides a hands-off, low
Maintenance solution to the task of tank draining which will extend the tank life, lower operating costs and improve shop air quality.
WARNING: This product is intended for use in industrial compressed air systems only. Do not install where pressures or temperatures can
exceed those listed above.
WARNING: Completely relieve all pressure from the system before attempting to install the drain. Disconnect compressor from all external
sources of pressure and electrical power. Employ approved lockout/tagout devices while working on the system. Failure to follow these
directions can result in serious personal injury and death.
Warning: Drain should only be activated when compressor is in operation. When the compressor is shut down, power supply to drain
should be disconnected. Failure to follow these directions will cause the solenoid coil to overheat and fail prematurely.
Rotate the Cycle knob (1) on the front of the unit to a setting from 1 to 60 minutes. This controls the period of time between drain activations. Rotate the
Drain knob (2) to a setting from 1 to 30 seconds. This controls the period of time the drain is open for each cycle. Observe drain operation over time
580 CARNEGIE STREET
MANTECA, CA 95337

FEATURES

Continuously Adjustable Drain and Cycle Times
Installs Easily
Reliable, Clog-Resistant Valve
Wye Strainer Included

SPECIFICATIONS

Adjustable Cycle Time:
Adjustable Drain Time:
Max. Working Pressure:
Max. Fluid Temperature:
Ambient Oper. Temperature: 35-165 F
Enclosure:
Electrical Supply:
Nominal Current:
Pipe Size:
To prevent scale and debris from entering the solenoid valve, the Wye Strainer
(4) must be installed upstream of the unit in the location indicated. Install drain in
proper flow direction as indicated. A field supplied manual shutoff valve (5) may
be installed upstream of the Wye Strainer and Drain Unit to facilitate service.
For best results, the drain should be mounted at a point lower than the tank drain
outlet and all piping should be pitched downhill to drain. In cases where normal
installation is not possible, the drain may be mounted at a point higher than the
(b) the drain cycle is adjusted to account for increased volume.
Connect unit to an approved, properly grounded electrical supply.
www.motorguard.com
INSTRUCTIONS
MODEL RF-2011
AUTOMATIC DRAIN
1-60 Min
1-30 Sec.
200 PSI
165 F
NEMA 1
115V/1Ph/60Hz
.25 Amps
1/4 NPT

INSTALLATION

OPERATION

1-800-227-2822
FAX 209-239-5114
Rev 10/13
.
FEATURES
.
.
.
33127

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RF-2011 and is the answer not in the manual?

Questions and answers

Summary of Contents for Motor Guard RF-2011

  • Page 1 FEATURES The Model RF-2011 Automatic Drain is designed to automatically drain your compressor tank at specified intervals. If provides a hands-off, low maintenance solution to the task of tank draining which will extend the tank life, lower operating costs and improve shop air quality.
  • Page 2 LIMITED WARRANTY Motor Guard Corporation assumes the responsibility of providing equipment that is free from defects in workmanship and material. Should this product fail due to a defect in workmanship or material, Motor Guard Corporation will repair or, at its option, replace the product without charge, other than the transportation charges, provided that the product is returned to the factory, transportation prepaid, within one year of the date of purchase.

Table of Contents