Page 1
USER MANUAL CANOPY COOKER HOOD KITCHEN EXTRACTOR FAN IN SILVER eiQ52CANOPY eiQ70CANOPY Thank you for choosing your electriQ cooker hood. This instruction manual is designed to provide you with all required instructions related to the installation, use and maintenance of the appliance. In order to operate the unit correctly and safely,...
SAFETY PRECAUTIONS Whilst this product is compliant with all safety requirements, incorrect or inappropriate use can lead to both personal injury and potential damage to property. Please read the contents of this instruction booklet thoroughly before fitting or using this appliance. •...
Page 4
and 75cm gives peak efficiency. • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels. • When the hood is vented externally and used with appliances which burn fuel (e.g.
V-FLAP INSTALLATION INSTALLATION If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminium, flexible pipe or non-flammable material with an interior diameter of 150/120mm). 1. Before installation, turn the unit off and ensure it is not plugged in. 2.
Page 6
3. Drill a hole in the cupboard, with hole wide 490*265(mm)for 52CM, hole wide 665*265(mm) for 70CM.Refer to pic below. Make sure the distance between the edge of the hole and the edge of the cupboard edge is at least 35mm. 4.
OPERATION 1. LIGHT: Use the switch to turn the light ON/OFF 2. FAN SPEED: Use the switch to adjust the fan speed with 1 being the lowest, 3 being the highest and 0 being off. CLEANING MAINTENANCE Before cleaning, switch the unit off and disconnect the power. Use a soft cloth moistened with hand-warm mildly soapy water or household cleaning detergent.
CONTROL PANEL SURFACE The inlay control panel can be cleaned using warm soapy water. Ensure the cloth is clean and well wrung before cleaning. Use a dry soft cloth to remove any excess moisture left after cleaning. Using neutral detergents and avoid using harsh cleaning chemicals, strong household detergents or products containing abrasives, as this will affect the appliance appearance and potentially remove any printing of artwork on the control panel and will void manufactures warrantee.
BULB REPLACEMENT The bulb must be replaced by the manufacturer, its service agent or similarly qualified persons. Always switch off the electricity supply before carrying out any operations on the appliance. When handling bulb, make sure it is completely cool down before any direct contact to hands.
TROUBLESHOOTING FAULT CAUSE SOLUTION The fan blade is Light on, but fan jammed. Switch off the unit. Repair to be carried does not work The motor is out by qualified service personnel only. damaged. Both light and Light bulb blown Replace the bulb with correct rating.
PRODUCT FICHE Symbol Value Unit Model identification eiQ70CANOPY Annual Energy Consumption 49.0 kWh/a hood Time increase factor Fluid Dynamic Efficiency 15.1 hood Fluid Dynamic Efficiency Class D class Energy Efficiency Index 76.8 hood Energy Efficiency class Class C Maximum airflow 381.3 Measured airflow rate at the 227.7...
Page 12
Symbol Value Unit Model identification eiQ52CANOPY Annual Energy Consumption 52.7 kWh/a hood Time increase factor Fluid Dynamic Efficiency 11.2 hood Fluid Dynamic Efficiency class Class E Energy Efficiency Index 81.8 hood Energy Efficiency class Class C Maximum airflow 364.7 Measured airflow rate at the 180.5...