Connector Details - Danaher Motion Amplifier MDM-7 Operator's Manual

High performance stepping motor drive module

Advertisement

MDM-7
Connector
Details
All MDM-7 module functions are brought out on a single 12 pin
screw-clamp style connector. To attach leads to the connector,
simply insert solid or standard wire in the 18 to 26 gauge range
and tighten the screw clamp. Specific pin functions are detailed
below.
Pin #1: Power Supply Ground
This pin, which is internally tied to pin #12, is to be connected to
the user provided D.C. power supply ground. Power supply
ground should be connected to the chassis to which the module
is mounted. To minimize radiated EMI (electrical noise), this
ground should also be connected to the shield enclosing the
motor leads. This shield should be extended to the motor case,
minimizing electrical noise generation by the motor.
Pin #2 Power Supply V+
This pin is to be connected to the user provided D.C. power sup-
ply positive lead. This supply need not be regulated, and can
range from +24 to +60 volts D.C. Care must be exercised that
power line fluctuations and power supply ripple do not exceed
the 60 volt maximum rating. For best operation, power supply rip-
ple should be held to 1 volt peak to peak or less. High speed
torque and power are proportional to the D.C. supply value;
accordingly, higher supply voltages will provide increased perfor-
mance. The penalty paid for this performance is increased motor
and module heating, as well as increased power supply weight
and volume.
Due to the efficiency of the recirculating drive design, total power
supply current requirements are reduced to approximately 1/3 of
the motors phase current rating for full coil operation, and 2/3 of
the current rating for half coil operation (for information on the
meaning of the terms "full coil" and "half coil," (see next page).
These current requirements are significantly reduced at idle, light
torque loading, and low speeds.
For users building their own unregulated D.C. power supplies, Fig.
1 details a typical design. It consists of an A.C. line filter, A.C.
fuse, on-off switch, transformer, diode bridge, filter capacitor, and
D.C. fuse. The transformer primary voltage should coincide with
the line voltage (115 V.A.C. or 230 V.A.C.), while the transformer
secondary voltage should equal .7 times the desired D.C. supply
voltage (for example, a transformer secondary voltage of 30 volts
A.C. will be required for a D.C. supply voltage of 42 volts). The
secondary current requirement should be 1.4 times the desired
D.C. supply current. For example, a stepping motor rated at 2.6
Figure 1
– 2 –
Drive Module Operator's Manual
Danaher Motion
tel: 603.893.0588
toll free: 800.227.1066
Amps per phase, and operated in half coil mode, will require a
D.C. supply current of 2/3 * 2.6, or 1.73 Amps. This corresponds to
a transformer secondary current rating of 2.45 Amps A.C. The fil-
ter capacitors value, in microfarads, should equal 8000 times the
D.C. supply current (14000 microfarads in the above example) to
ensure a ripple voltage below 1 volt. Smaller capacitors will also
work, but result in increased supply voltage ripple. This can
impair performance if the motor is required to produce close to
its maximum torque output.
A 5 Amp, fast blow fuse must be inserted in the positive side of
the D.C. power supply, to protect against motor shorts to ground,
etc. As described below, the motor MUST be wired in place
before D.C. power is applied. Never connect or disconnect the
motor while D.C. power is applied. The power supply leads (V+
and GND) should be kept as short as possible. If these leads
exceed 10 inches, install both a .1 mfd. and 100 mfd. capacitor
rated at 100 volts or higher across pins #1 and #2 at the drive
module.
Pins #3 and 4: Motor Coil 1
Pins #5 and 6: Motor Coil 2
WARNING! No connection or disconnection of the motor leads
should be performed while the module D.C. power supply is
active. Always wire the motor leads prior to applying D.C. power.
If connectors are present along the motor cable, always turn off
D.C. power prior to connecting or disconnecting the motor. The
extremely high voltage, fast rise-time transients produced when
the motor is connected or disconnected can destroy the FET out-
put stage of the MDM-7 module. Damage caused by motor con-
nection/disconnection with power applied is not covered under
the DPS warranty.
Precision Systems Group
7C Raymond Avenue, Salem, NH 03079
fax: 603.893.8280
url: www.danaherprecision.com