Page 1
INNOVATION IS OUR DRIVING FORCE COMITRONIC - ADAPTABILITY IS OUR CULTURE AMX SERIES INSTRUCTION MANUAL CONTACTLESS CODED SAFETY SENSOR FOR MACHINE SAFETY GUARDS / DOORS DIRECT CONTROL OF DANGEROUS MOVEMENT BY PILOT DUTY CONTACTS STAND ALONE Direct drive SIL 2 CAT.3...
The dry contacts of component X5 have an 8 A breaking capacity limited to 1/4 of its value to avoid any risk of sticking by carbonization. The value of the B10d is clearly displayed at 2 A with 2,000,000 cycles, which makes it possible to directly control power contactors. SYTCOM software: https://www.comitronic-bti.fr/fr/sytcom A calculator for ISO 13849-1...
Associated locking devices for guards: ISO 14119 1. The different locking devices according to ISO 14119 Locking devices for dangerous machinery guards are subject to ISO 14119. There are three component technologies: Technologies Device Power switch Sensor Roller Hinge Reed ACOTOM RFID Mechanical Magnetic Induction or RFID Standard Type ISO 14119 2.
Associated locking devices for guards: ISO 14119 3. The ACOTOM process 3.1. The birth of a revolutionary technology We put the first contactless encoded security sensor with a revolutionary process on the market in 1993. It uses a double-coded magnetic field and a diagnostic output, independent of the safety contacts, which traces the product's position.
Miscellaneous information Safety sensors and RFID technology 1. RFID technology 1.1. Why ? The RFID in the safety sensors is of interest if you need to have a different code for each guard, on each machine, and, in particular, for the sensors placed on the outside of the machines, or thus accessible. According to ISO 14119, RFID coding must be classified as "high".
Contactless safety sensor, with redundant duty pilot contacts AMX 3, AMX 4, AMX 5 A unique solution 2 contacts in the international market redundant diagnostic Acotom Process 3 1 output Double leg auxiliary Suitable for applications bracket of machine safety Stand alone solution Connection IEC 62061: SIL 2...
Contactless safety sensor, with two potential-free contacts AMX 3, AMX 4, AMX 5 6. Assembly instructions 7. Annual periodic inspection a) Drill the holes of the mounting bracket at F= 4.5 This product should be checked periodically at mm, with a center distance of 83 mm least once a year.
Contactless safety sensor, with two potential-free contacts AMX 3, AMX 4, AMX 5 11. Installation principle with AMX5-MKT for a PLd performance level Cable 50 cm T-Splitter T-Splitter FMKT cord FKT cord M12 molded-in Equipment for this installation: AMX5-MKT: 3 T-Splitter: 2 2 7 1 FMKT: 5 m, 10 m or 15 m...
Contactless safety sensor, with two potential-free contacts AMX 3, AMX 4, AMX 5 13. Installation principle with AMX3-4-5 for a PLd performance level 13.1. AMX3 13.2. AMX4 cable 3, 6, 12 m cable 3, 6, 12 m testing info door open testing 13.3.
AMX Series DECLARATION OF CONFORMITY MANUFACTURER OF SAFETY MATERIAL 14 rue Pierre Paul de Riquet 33610 Canéjan phone : +33 564 100 452 www.comitronic-bti.net 5008891 EU DECLARATION OF CONFORMITY This document is the conformity declaration concerning safety switches and relays, conforming to the...
Page 12
COMITRONIC - 14 Rue Pierre Paul de Riquet 33610 Canéjan +33 5 64 10 04 52 www.comitronic-bti.com AMXEN_250618_v0.0...