NeuLog current logger sensor
NUL-202
The NeuLog current sensor can be used for any science experiment which
utilizes current readings. It is used in the fields of Physics, Electronics,
Chemistry, Biology, etc.
The sensor comes pre-calibrated so you can start experimentation right out
of the box using any of the following guides.
Hundreds of possible experimental subjects that can be performed with the
NUL-202 sensor are: Fuel cells, battery chemistry, electrical parallel
circuits, electrical series circuits and electronics.
The current sensor's measurement units are:
Amperes (A): Amperes are the SI base unit of electric current.
Quick start procedure:
PC or Mac Computer
Materials needed:
 NUL-202 Current Sensor
 USB-200 USB Module
 USB to mini USB cable (which comes with the USB-200)
Your current sensor needs to be connected to a USB-200 module. The USB-
200 module then connects to a computer via a USB to mini-USB cable.
NEULOG CURRENT LOGGER SENSOR GUIDE
Please note that you cannot plug the current sensor directly into the
computer.
Resident PC software and browser based application can be downloaded for
free at
www.neulog.com/Download/SoftwareandApplication.aspx
software user guide.
Note: Make sure not to download and install both types of software they
will conflict on the computer.
Procedure:
1.
Install the NeuLog software.
2.
Connect the USB-200 module to the PC or Mac.
3.
Connect the current sensor to the USB-200 module (they directly plug
together). Please note no calibration is required for this sensor.
4.
Open the NeuLog software.
5.
Once a current sensor logo appears on the left side of the screen, the
probe has been automatically identified and you can begin
experimentation.
If the current sensor is not automatically identified, click the "Search
6.
for sensors" icon to find the sensor.
Click the "On-line experiment" button; this will open a graph below.
7.
Click on the "Module setup" button located on the current sensor icon
8.
in the module window to change the sensor's settings if need be.
9.
Click on the experiment set up button to change the experiment
settings if need be (experiment duration for example).
10. The current sensor will give a live reading in the box to the left of the
screen while plugged in.
11. To run an experiment and collect data, click "Run experiment".
12. To end data collection early, click "Stop experiment".
as well as a full

Advertisement

loading

Summary of Contents for NeuLog UL-202

  • Page 1 NUL-202 Resident PC software and browser based application can be downloaded for free at The NeuLog current sensor can be used for any science experiment which as well as a full www.neulog.com/Download/SoftwareandApplication.aspx utilizes current readings. It is used in the fields of Physics, Electronics, software user guide.
  • Page 2 WIFI-201 module will create a closed NeuLog WiFi network which will screen for the current sensor. The icon will display real time data. stream the NeuLog data to the device of your choosing. Once your device is 14. Click on the “Module setup” button located on the current sensor icon wirelessly connected to the NeuLog network you can run experiments and in the module window to change the current probe settings if need be.
  • Page 3 Select which experimental data to upload. (5 experimental runs can be Off-line experiments stored at one time on the NUL-202 current sensor) (Off-line experiments are when you do not have a sensor connected directly to a computer, tablet, smartphone, or NeuLog viewer). Restoring sensor’s factory default settings: Materials needed: Procedure: ...
  • Page 4  Rugged plastic ergonomic case.  4 mm power and ground plugs for easy connectivity The NeuLog current sensor houses a shunt resistor and an amplifier. The  Push button switch for Start/Stop experiments in off line mode. circuit's current passes through the shunt resistor and its electric potential is ...
  • Page 5 Maintenance and storage: Flexible, simple, fast, forward thinking. www.neulog.com info@neulog.com  Never submerge the NeuLog plastic body in any liquid. A: 850 St Paul Street, Suite 15, Rochester, NY 14605  Do not allow liquid into the current sensor’s body. P: 1.866.553.8536 ...

This manual is also suitable for:

Nul-201