Hitachi CPX1 Service Manual page 17

Hide thumbs Also See for CPX1:
Table of Contents

Advertisement

3. Maintenance point
Actual formation
4. Cleaning the panels and optical filters
(1) Turn on the set and lit on the lamp.
(2) By using swab and air duster, remove the dust. Focusing dust makes you check the dust on screen.
5. Re-assembly
(1) Turn off the set and unplug the power cord.
(2) Remove an insulator from S801.
(3) Screw down the PWB assembly MAIN and connect the LCD panel flexible cables to the PWB assembly MAIN.
(4) Re-assemble the set.
(5) While re-assembling, please clean the intake filter by using a vacuum cleaner.
All manuals and user guides at all-guides.com
CPX1(M1-20)
Separated formation
17
Optical filter
Each color part has same
construction.
By using swab and air duster,
you can easily remove dust
from panel and optical filter.
Panel
• While removing the dust, separated dust will
be blown off by air cooling system.
• Please pay attention not to damage panels
and optical filters.

Advertisement

Table of Contents
loading

This manual is also suitable for:

M1-20

Table of Contents