3.2 Test Data:.Play Audio CD
Table 3.2.1
Antenna
Type
Polar.
(MHz)
BILOG
Horiz.
67.86
BILOG
Horiz.
100.18
BILOG
Horiz.
186.10
BILOG
Horiz.
196.02
BILOG
Horiz.
200.11
BILOG
Horiz.
215.99
BILOG
Horiz.
240.01
BILOG
Horiz.
272.27
BILOG
Horiz.
300.14
BILOG
Horiz.
323.65
BILOG
Horiz.
339.27
BILOG
Horiz.
600.34
BILOG
Horiz.
646.47
BILOG
Horiz.
905.39
* NOTE:
Margin = Corrected Amplitude – Limit
Corrected Amplitude = Radiated Amplitude + Antenna Correction Factor + Cable Loss –
A margin of -8dB means that the emission is 8dB below the limit ( in compliance)
BILOG Antenna Distance:
Tested by:
_________________________
David Y.Y. Wu
International Standards Laboratory
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
Open Field Radiated Emissions (Horizontal)
Meter Reading
Freq.
Ampl.
Ant.
(dBuV)
(dB/m)
7.80
5.36
11.70
10.62
5.00
8.74
2.50
8.52
6.80
8.40
4.70
8.69
4.40
10.51
4.60
12.09
8.10
12.60
9.70
13.23
10.10
13.63
9.20
18.22
5.20
18.71
4.00
20.23
Pre-Amplifier Gain
10 meter ,
Declaration of Conformity
-7-
Correction Factor
Cable
Pre-Ampl.
(dB)
(dB)
1.39
0.00
1.66
0.00
2.26
0.00
2.31
0.00
2.33
0.00
2.44
0.00
2.59
0.00
2.79
0.00
2.95
0.00
3.08
0.00
3.18
0.00
4.46
0.00
4.67
0.00
5.88
0.00
Horn Antenna Distance:
Report Number: ISL-00A105FB
Corrected Emissions
Ampl.
Limit
Margin*
(dBuV/m)
(dBuV/m)
(dB)
14.55
30.00
-15.45
23.98
30.00
-6.02
16.00
30.00
-14.00
13.33
30.00
-16.67
17.53
30.00
-12.47
15.83
30.00
-14.17
17.50
37.00
-19.50
19.48
37.00
-17.52
23.65
37.00
-13.35
26.02
37.00
-10.98
26.91
37.00
-10.09
31.88
37.00
-5.12
28.59
37.00
-8.41
30.12
37.00
-6.88
3 meter