1
7. Install this unit in the rear panel of the PRV-LX1.
•
Fit the two projections in this unit into the two
A
hooks in the PRV-LX1and secure the unit with
the two supplied screws (silver no washers).
First tighten screw
•
Install the PRA-BD11 input board in the left
expansion slot (as seen from the rear)
The PRA-BD12 output board is installed in
the right expansion slot (as seen from the rear).
B
Notes:
•
Do not use screws removed in Step 2 or Step 3.
•
Make sure that no cables routed in Step 4 are located
beneath the unit.
8. Connect the PRA-BD11 input board and the PRA-BD12 output board to the PRV-LX1 with
the FFC and 4-pin cables.
Notes:
•
The cables for connecting the PRA-BD11 input board and the PRA-BD12 output board differ.
C
Refer to the figures below to make sure that each cable is properly oriented and connected to the
correct connector.
•
Watch out for sharp corners (on arms, for example, see Step 9) when connecting and routing cables.
PRA-BD11 input board connections
•
Connect the 4-pin cable (M) already connected to connector A to connector a
cable (M) with a cable clamp before routing it.
•
Unlock connectors b and d by raising their stoppers.
•
Insert the FFC cable (M) already connected to connector B in connector b and lock by lowering
the stopper. See figure and note below (*).
D
•
Insert the FFC cable (L) already connected to connector D in connector d and lock by lowering
the stopper. See figure and note below (*).
Note:
Connect the FFC cable to the unit with the blue reinforced side facing up.
Blue reinforced side
E
Unlocked
*
Make sure that the two lines in the reinforcement
are not visible when the connector is locked. If
they are still visible, disconnect and connect the
FFC cable again.
F
64
1
2
and then screw
(two lines)
Locked
2
3
Place the label
,
side facing up
.
a
d
b
D
B
A
PRA-BD11
3
4
PRA-BD11 input board or
PRA-BD12 output board
Expansion slot on the
rear of the PRV-LX1
.
Secure the 4-pin
PRA-BD11
input board
4-pin cable (M)
FFC cable (M)
FFC cable (L)
Cable clamp
4