New Life Radiology DIGISMILE Manual

New Life Radiology DIGISMILE Manual

Digital intraoral scanner system

Advertisement

Quick Links

DIGISMILE
Digital Intraoral Scanner System
I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIGISMILE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for New Life Radiology DIGISMILE

  • Page 1 DIGISMILE Digital Intraoral Scanner System...
  • Page 2 User access to this manual does not constitute our license to the intellectual property rights of the product. The rights to modify, update and interpret this manual are owned by NEW LIFE RADIOLOGY. Responsibility of the manufacturer NEW LIFE RADIOLOGY will be responsible for the safety, reliability...
  • Page 3 Manual Application This manual describes functions and operations of the digital intraoral scanner system. Readers This manual is intended for clinic staff and other authorized users. Legend and designation Any legend provided in this manual is used for illustrative and descriptive purposes only.
  • Page 4: Table Of Contents

    Contents Chapter 1 Safety Guide….……………………. .…………...…..….. 1 1.1 Intended purpose….……………………. .……………..…….….1 1.2 Contraindications….……………………. .……………...….……. 1 1.3 Equipment….……………………. .……..……………….……….. 1 1.4 Operating conditions….……………………. .…………..…..…... 1 1.5 Warnings and notes….……………………. .…………..…..……. 2 1.5.1 Safety Notice….………………. .……………….…….……3 1.5.2 Warning….……………………. .………………...…………4 1.5.3 Note….……………………. .……..…….………..………..4 1.6 Description of symbols….…………………….
  • Page 5 5.3.2 Adding patient information….……………………..…….. 18 5.3.3 Adding New Cases..……………. .……………...…….….20 5.3.4 Choice of indications….…………………………..…. .….20 5.3.5 Scanning….……………………. .……..…………...….….22 5.3.6 Editing Images….……………………. .…………..…..… 25 5.3.7 Deleting images….……………………. .………….…..…26 5.3.8 HD Photos….……………………. .……………….………26 5.3.9 Image Editing….……………………. .……………..…...28 5.3.10 Sending an order….…………………………….. .……. 32 5.4 System configuration….………………………………...
  • Page 6: Chapter 1 Safety Guide

    Chapter 1 Safety Guide This section presents important safety information on the operation of the product. 1.1 Intended purpose This product can be used in medical institutions to perform oral scanning, images of teeth and other tissues, making a 3D digital model for CAD/CAM for prosthetic design and processing, which can be used for restoration system and other applications.
  • Page 7: Warnings And Notes

    Video Card NVIDIA GeForce NVIDIA GeForce GTX 1050 Ti 960M USB port USB 3.0 high speed USB 3.0 high speed port port Table 1-1 Computer Configuration 1.5 Warnings and Notes For safe and effective use of the system and to avoid system failures, the user should first be familiar with the operations in the Windows system, read this manual carefully and be familiar with the Euclide Software and its applications.
  • Page 8 environments exposed to a mixture of flammable anesthetic gases and air or oxygen or nitrous oxygen.  This system is not equipped with a waterproof device and therefore should not be used in places exposed to moisture or water.  Do not spray liquids on or inside this equipment, otherwise there is a risk of electric shock.
  • Page 9: Description Of Symbols

     Any device or accessory used must be disposed of in accordance with local laws and regulations or returned to the manufacturer or dealer for proper disposal.  Select a power cord with adequate rating to minimize the risk.  No part of the system is user manageable, so any maintenance must be done by our service personnel.
  • Page 10 Information about the manufacturer This side up Fragile Protect from the rain Maximum storage levels Temperature limits Relative humidity limit (non- condensing) Atmospheric pressure limit...
  • Page 11: Chapter 2 Product Overview

    Chapter 2 Product overview 2.1 Product overview The device is designed to acquire 3D images in the following ways:  Lower jaw  Upper jaw  Occlusal relation The image below shows the main components of the device. Scan Button Power Button Scan Tip Handpiece...
  • Page 12: Chapter 3 Installation And Connection

    Chapter 3 Installation and Connection Chapter 5 Euclide Software Operation Guide 5.1 Overview Euclide is the software of the NEW LIFE RADIOLOGY Digital Intraoral Scanner. It contains three modules, including case creation, scanning and image editing. Helps to acquire intraoral scan data in "restorations", "orthodontics"...
  • Page 13: Software Operations

    5.3 Software operations 5.3.1 Access to Euclide software 1. Double-click Euclide's shortcut icons on your computer desktop to open it and access the login screen, as shown below 2. Choose an account to access the main software screen 5.3.2 Adding Patient Information 1.
  • Page 14 2. Add Patient ID, Name, Gender, Age and Annotations in the window and click OK to add a new patient. Note: Patient ID, Name and Genders are required fields. 3. The patient's name will be displayed in the patient list 4.
  • Page 15: Adding New Cases

    5.3.3 Adding new cases Click enter case creation screen below. 5.3.4 Indications of choice Indications of choice 1. Choose a dental laboratory and a delivery date. 2. Choose the desired exam items from the Patient Indication List. Indications Items for exam Complete crown, veneer,...
  • Page 16 3. Select the teeth that need restoration on the dentition. Information about the process will appear on the right of the screen. 4. Click Add Special Question at the bottom of the screen, enter your question and click OK in the pop-up dialog box. The request will be displayed below.
  • Page 17 5.3.5 Scanning Scan Screen 9 10 11 12 13 14 Descrizione Scan the patient's teeth on the Scan of the upper jaw upper jaw. Scan the patient's teeth on the Lower jaw scan lower jaw. Scan the patient's teeth for the Scan of occlusal relation occlusal relation.
  • Page 18: Scanning

    Scanning Click the icon to start scanning. Preview Preview the scanned image. Stop Stop scanning to get final data. HD Photo Click HD photos to take oral photos. Adjust the 3D image and eliminate Trim the extra parts. Delete Delete the current image. 5.3.5.1 Scanning Note: Since saliva on the tooth surface reflects light and...
  • Page 19 3. Let the scanning mirror of the scanning tip point towards the teeth to be scanned. When scanning starts, the scanned image will be displayed on the screen as below. Note When scanning starts, the scan icon on the screen changes to Click to pause scanning.
  • Page 20: Deleting Images

    5. Follow steps 1-4 above to complete the scans of the upper jaw, lower jaw, and occlusal relation. Note If the upper jaw scan and the lower jaw scan are performed, the occlusal relation scan is required to proceed. 6. When the 3D image is generated, hold down the right mouse button and drag the image to rotate it with the mouse;...
  • Page 21 4.Press the scan button on the device or click in the center of the screen to take photos, as below. 4. Click the photo in the center to enter the photo list screen to view the photos. 5. There are two photo preview modes, slide mode and list mode, which can be changed by clicking the corresponding mode, as shown in the following figure.
  • Page 22 6. Click on in the upper right corner of a photo to delete an extra photo. 5.3.9 Editing the image When a 3D image is captured, click Next at the bottom right of the screen to enter the image editing screen as below. 5.3.9.1 Occlusal image - split joint If an occlusal relation image is captured, the icon will be...
  • Page 23 The stages of the split joint of the occlusal image are as follows. 1. Hold down the right mouse button and move it to rotate the occlusal image to an easily aligned angle. Rotate the images of the upper and lower jaws to the same angle as the occlusal image in the same way as in the figure above.
  • Page 24 3. Mark three points on the lower jaw image and the lower jaw of the occlusal image separately according to the method of step 2. If the alignment result is not satisfactory, click Reset to start the mark again. 4. Exams with both sides scanned need to proceed with two occlusal images - split joint.
  • Page 25 5.3.9.2 Occlusal relation 1. Click Occlusion at the bottom of the screen to view the occlusal relation as below. 2.Click Open Jaw / Close Jaw to view images. 3. Click OK to exit the view. 5.3.9.3 Marking of teeth Mark the positions of the teeth for the teeth in the patient case information in order from the upper jaw to the lower jaw and from left to right.
  • Page 26: Sending An Order

    2. Select and drag the blue point with the left mouse button to adjust the position of the point on the tooth. 3. When all the necessary teeth are marked, click OK at the bottom to complete the tooth marking. 5.3.10 Sending an order When you finish editing the image, click Next to enter the order confirmation screen as below.
  • Page 27: System Configuration

    Click Submit at the bottom of the screen to display a confirmation dialog. Click OK to store all scanned images in the database, which can be viewed in the order list on the home screen by clicking View Details. .5.4 System configuration 5.4.1 User management 1.
  • Page 28: System Settings

    5. Select an account to delete in the user list, click Delete account to delete it. 5.4.2 System settings 1. Enter a password on the login screen to access the main screen. 2. Click Administrator> Settings in the upper right corner of the home screen to display the system settings dialog as below.
  • Page 29: Closing The Software

    Note When the audio scan is activated, the device beeps each time it starts or stops scanning. 5.5 Closing the software 1. Click Admin> Log Out in the upper right corner of the main screen. 2. Click OK to log out of the current account. 3.
  • Page 30: Cleaning The Device

    6.1 Cleaning the device 1. Keep your device clean. 2. If necessary, clean with 75% medical alcohol. 6.2 Changing and sterilization of scan tips Replacement and sterilization of scan tips 1. A sterilized scan tip must be installed before re-scanning. 2.
  • Page 31: Maintenance

    least 20 minutes. For details, refer to the o-benzaldehyde disinfectant user manual. c.Remove the scanning tip from the o-benzaldehyde disinfectant and clean it with clean water. For details, refer to the user manual of the o-benzaldehyde disinfectant. d. Dry the scanning tip. Use a sterile, non-abrasive cloth or tissue to dry the scanning tip.
  • Page 32: Chapter 8 Troubleshooting

    Accessory Type Quantity Adaptor HPU63A-10 5 Handpiece DIGISMILE-10 Tips DIGISMILE-20 Holder/base DIGISMILE-30 Table 7 – 1 standars accessories list The digital intraoral scanner system and its accessories can be purchased from the manufacturer or local dealer. Chapter 8 Troubleshooting This section lists some basic troubleshooting steps you can use to fix common problems with your device.
  • Page 33: Chapter 9 Specifications And Parameters

    Chapter 9 Specifications and parameters Product Specifications : Component Parameter Sensor CMOS da 1 / 3,6 " Lighting LED:Red, Green, Blue Scanning Mode -2~12 mm Anti-fog Actively heated tip Technology Cable Digital connection USB3.0 Dimensions of the 20mm * 20 mm * 19.2mm front of the toe Nominal voltage 100-240VCA...
  • Page 34: Chapter 10 After Sales Service

    Chapter 10 After Sales Service NEW LIFE RADIOLOGY guarantees that all products supplied meet the specifications shown on the label and do not have defects in material or workmanship within the warranty period. The warranty period extends to 2 years from the date of the sales invoice.
  • Page 35: Appendix 1 Manufacturer Information

    Appendix 1 Manufacturer Information Manufacturer: NEW LIFE RADIOLOGY SRL Product Name: Digital Intraoral Scanner Product models: DIGISMILE Manufacturer's address: 10095 - Grugliasco (TO) - Italy. Corso Giuseppe Canonico Allamano 13/15 INT.G Production date: see the label for details Product life cycle: 5 years...

Table of Contents