Advertisement

USER MANUAL
&
(Rev. 5.11.0.2 - ENG)
www.axeltechnology.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OXYGEN1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for AxelTech OXYGEN1000

  • Page 1 USER MANUAL & (Rev. 5.11.0.2 - ENG) www.axeltechnology.com...
  • Page 2: Table Of Contents

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG SUMMARY SUMMARY ................................... 2 SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA ..................... 3 PREFACE…………..................................3 SAFETY WARNINGS ................................4 CONSIGNES DE SÉCURITÉ IMPORTANTES ..........................6 ISTRUZIONI IMPORTANTI PER LA SICUREZZA ........................8 WICHTIGE SICHERHEITSHINWEISE ............................
  • Page 3: Safety Warnings/Istruzioni Per La Sicurezza

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA SAFETY WARNINGS CONSIGNES DE SÉCURITÉ IMPORTANTES ISTRUZIONI IMPORTANTI PER LA SICUREZZA WICHTIGE SICHERHEITSHINWEISE INSTRUCCIONES IMPORTANTES DE SEGURIDAD (Rel. 1.6) PREFACE For your safety and to prevent the warranty from being accidentally invalidated, please read carefully all the texts marked with the Warning Symbols The information contained in this manual is subject to change without notice and does not constitute a commitment by the seller.
  • Page 4: Safety Warnings

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG SAFETY WARNINGS The installation and servicing instructions in this manual are for use by qualified personnel only. Read All Instructions. All safety and operating instructions must be read before operating the product.
  • Page 5 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG This symbol alerts you to the presence of dangerous voltage inside the closure – voltage that may be sufficient to constitute a risk of shock. Do not perform any servicing other than that contained in the operating instructions.
  • Page 6: Consignes De Sécurité Importantes

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG CONSIGNES DE SÉCURITÉ IMPORTANTES Lire ces consignes. Conserver ces consignes. Observer tous les avertissements. Suivre toutes les consignes. Ne pas utiliser cet appareil à proximité de l’eau. Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant. Ne pas installer à...
  • Page 7 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Ce symbole indique la présence d'une tension dangereuse dans l'appareil constituant un risque de choc électrique. Ce symbole indique que la documentation fournie avec l'appareil contient des instructions d'utilisation et d'entretien importantes. Avant de modifier le commutateur de changement de tension ou replacer le fusible il faut débrancher l’appareil de la prise électrique.
  • Page 8: Istruzioni Importanti Per La Sicurezza

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG ISTRUZIONI IMPORTANTI PER LA SICUREZZA Leggere le presenti istruzioni. Conservare queste istruzioni. Osservare tutte le avvertenze. Seguire scrupolosamente tutte le istruzioni. Non usare questo apparecchio in prossimità di acqua. Non ostruire alcuna apertura per il raffreddamento. Installare l’apparecchio seguendo le istruzioni. Non installare l'apparecchio accanto a fonti di calore quali radiatori, aperture per l'afflusso di aria calda, forni o altri apparecchi (amplificatori inclusi) che generino calore.
  • Page 9 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Il prodotto deve essere utilizzato solo se integro e non danneggiato. Se il prodotto è stato sottoposto a forti urti o fosse venuto a contatto con liquidi è necessario contattare l'assistenza prima di accenderelo.
  • Page 10 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Questo simbolo indica la presenza di alta tensione all'interno dell'apparecchio, che comporta rischi di scossa elettrica. Questo simbolo indica la presenza di istruzioni importanti per l'uso e la manutenzione nella documentazione in dotazione all'apparecchio. Non sostituire il fusibile o cambiare la tensione di alimentazione senza aver prima scollegato il cordone di alimentazione.
  • Page 11: Wichtige Sicherheitshinweise

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG WICHTIGE SICHERHEITSHINWEISE Diese Hinweise LESEN. Diese Hinweise AUFHEBEN. Alle Warnhinweise BEACHTEN. Alle Anweisungen BEFOLGEN. Dieses Gerät NICHT in der Nähe von Wasser verwenden. KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen. Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die Wärme erzeugen.
  • Page 12 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Dieses Symbol zeigt an, dass gefährliche Spannungswerte, die ein Stromschlagrisiko darstellen, innerhalb dieses Geräts auftreten. Dieses Symbol zeigt an, dass das diesem Gerät beiliegende Handbuch wichtige Betriebs- und Wartungsanweisungen enthält. Vor Änderung der Netzspannung oder Sicherungswechsel Netzkabel trennen.
  • Page 13: Instrucciones Importantes De Seguridad

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG INSTRUCCIONES IMPORTANTES DE SEGURIDAD LEA estas instrucciones. CONSERVE estas instrucciones. PRESTE ATENCION a todas las advertencias. SIGA todas las instrucciones. NO utilice este aparato cerca del agua. NO obstruya ninguna de las aberturas de ventilación. Instálese según lo indicado en las instrucciones del fabricante.
  • Page 14 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Este símbolo indica que la unidad contiene niveles de voltaje peligrosos que representan un riesgo de choques eléctricos. Este símbolo indica que la literatura que acompaña a esta unidad contiene instrucciones importantes de funcionamiento y mantenimiento.
  • Page 15: Unpacking And Inspection

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG UNPACKING AND INSPECTION Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the shipping carton and the contents for any signs of physical damage.
  • Page 16: First Installation Recommendations

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG FIRST INSTALLATION RECOMMENDATIONS POWER SUPPLY CABLE A power supply cable of approx. 2 mt. lengths is supplied with the device, which has a moulded IEC plug attached – this is a legal requirement. The type of plug for the power supply depends on the country in which it is delivered.
  • Page 17: Oxygen 1000 & Oxygen+ 2000 Installation Note And First Step

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG OXYGEN 1000 & OXYGEN+ 2000 INSTALLATION NOTE AND FIRST STEP Best setup location Oxygen 1000 & Oxygen 2000 should be installed avoiding direct sunlight, close proximity to radiators and air conditioning, dust, water, and chemicals. Choose a console location that permits a clear view of the indicators on the device and ensures a sufficient heat dissipation of the device.
  • Page 18: Introduction

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG INTRODUCTION  Oxygen 1000 & Oxygen 2000 are the new concept digital console and follow the new Oxygen 3000 standard in the broadcast market.  Characterized by an elegant design and compact size, Oxygen 1000 & Oxygen 2000 have been designed for both On-Air and Production studios.
  • Page 19: General Description

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG GENERAL DESCRIPTION 1.1 OXYGEN 1000 DIMENSIONS GENERAL DESCRIPTION |OXYGEN 1000 DIMENSIONS...
  • Page 20: Oxygen 2000 Dimensions

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 1.2 OXYGEN 2000 DIMENSIONS GENERAL DESCRIPTION|OXYGEN 2000 DIMENSIONS...
  • Page 21: Talkbox Dimensions

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 1.3 TALKBOX DIMENSIONS GENERAL DESCRIPTION |TALKBOX DIMENSIONS...
  • Page 22: Input Connections

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 1.4 INPUT CONNECTIONS ANALOG IN (LINE-2, LINE-3, LINE-4) – RJ45 (SPTF AOIP – LAN DANTE – RJ45 (CAT 6 cable). Cable) for 3 Stereo analog audio inputs. 8 Stereo digital audio inputs over Ethernet. These Pinout - in scheme inputs are optional.
  • Page 23: Output Connections

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 1.5 OUTPUT CONNECTIONS DIGITAL OUT on XLR Male connector for the digital AOIP – LAN DANTE – RJ45 (CAT 6 cable). AESEBU output audio signal. 8 Stereo digital audio outputs over Ethernet. These outputs are optional.
  • Page 24: Communication Connectors

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 1.6 COMMUNICATION CONNECTORS HDMI Output ANALOG MIC IN 2, ANALOG MIC IN 3 - RJ45 (SFTP Standard HDMI Female Connector – External Monitor. Cable) – cable for the Balanced Audio (Mic 2/3 Input) and for 2 GPI and for 1 GPO signals on each connector.
  • Page 25: Talkbox Connections

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 1.7 TALKBOX CONNECTIONS 1. Power Supply 2. Mic Light 12VDC 1A 2 PIN Screw Connector - (12VDC output). 3. Studio Light 5. Mic Input 4. 2 PIN Screw Connector - (12VDC 6.
  • Page 26: First Console Ip Addres Assignment

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG FIRST CONSOLE IP ADDRES ASSIGNMENT Connect a LAN cable to the OXYGEN 1000 or to your OXYGEN 2000 LAN port on the back panel of the device. The device is automatically discoverable as DHCP client in your network. Download the Oxygen Remoter setup file from the following URL: HTTPS://WWW.AXELTECHNOLOGY.COM/PUBLIC/OXYGENREMOTER/OXYGENREMOTERSETUP.EXE Launch the downloaded OxygenRemoterSetup.exe installation file...
  • Page 27 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Click on your device and click on Then click on to start the real-time communication with the target device. NB: Default password: root Localhost dropdown menu is used if you need to change your IP ADDRESS because of your second PC LAN board or your second IP Address: FIRST CONSOLE IP ADDRES ASSIGNMENT |TALKBOX CONNECTIONS...
  • Page 28 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG SETUP > GENERAL > COMMUNICATIONS > TCP-IP If DHCP = YES, the console IP ADDRESS-1 will be automatically assigned by your router. If DHCP = NO Type the desired IP ADDRESS in the ADDRESS 1 field. This parameter is useful to remotely control your device.
  • Page 29: Surface

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG SURFACE To analyze the console surface we can split OXYGEN 1000 and OXYGEN 2000 in the following 4 same partitions: 3.1 OXYGEN 1000 - PARTITION 1. CHANNEL CONTROLS 2. OUTPUT LEDMETERS 3.
  • Page 30 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 3.2 OXYGEN 2000 - PARTITION 1. CHANNEL CONTROLS 2. OUTPUT LEDMETERS 3. MONITORS SECTION 4. BLUETOOTH BUTTON SURFACE|TALKBOX CONNECTIONS...
  • Page 31 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 3.2.1 CHANNEL CONTROLS A. CHB – BUTTON FOR SOURCE SWITCHING BETWEEN PRIMARY SOURCE (CHA) AND THE SECONDARY ONE (CH B) B. GAIN – KNOB FOR THE ADJUSTING OF THE INPUT SOURCE LEVEL C.
  • Page 32 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG ChB BUTTON For every channel, you can set two different input sources, ChA and ChB. By pressing the ChB button, you can switch over between A/B sources. Button in OFF position: the ChA is active. Button in ON position: the ChB is shown.
  • Page 33 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG You also have another OXYGEN REMOTER section in which you can define the audio sources (A and B) from the menu: SETUP / AUDIO / CHANNELS SURFACE |TALKBOX CONNECTIONS...
  • Page 34 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG GAIN The GAIN knob rotation increases or decreases the input source gain. The GAIN value is associated with the selected source ChA/ChB, not with the physical channel. By switching the source, the gain is always suitable to the connected one. The GAIN value is the latest setting is seated by the knob.
  • Page 35 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG F1 BUTTON Telephone Channel / Telco (Default Setting). The same parallel workflow could be executed from the device surface or from the OXYGEN REMOTER control software as explained by the below image: In the presence of an incoming call, the F1 button starts blinking, By pressing F1 it will hook the call.
  • Page 36 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG PGM/SUB BUTTONS The PGM, SUB buttons forward or not the output signal to the related BUSS, PGM and SUB are 2 logical audio BUSS not 2 phisical audio BUSS. the RGB LEDs under the related button has three different states color: 1) disabled (LED OFF) 2) enabled + Channel ON 3) enabled + Channel MUTE/Warm state...
  • Page 37 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG ON/OFF channel status could depend on:  ON/OFF of the OXYGEN REMOTER ON button.  Fader position changeable by o the console surface o OXYGEN REMOTER control software NB: It’s possible to set AUX-1 and AUX-2 to be POST-Fader, PRE-Fader, or PRE-FADER ALWAYS ON. This choice is settable from the OXYGEN REMOTER settings menu of every channel input source.
  • Page 38 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG PFL button enables/disables the channel pre-listening. When the PFL LED is ON, the pre-listening is enabled on that channel. The 2 different status of this PFL button is always related with the channel (in this example CHANNEL-2).
  • Page 39 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG By going to SETUP / AUDIO / SETTINGS can change the PFL MODE between SINGLE PFL PFL. SINGLE PFL: Allowed to select/listen to only one PFL per time. SUM PFL: Allowed to select many PFL and listening to them all at the same time as shown in the following picture: FADER A command is generated every time the Fader passes through the threshold value:...
  • Page 40 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Differently by EQ and GAIN, FADER status is not associated with the source, it is associated with the physical channel. Changing the source, the FADER attenuation and the FADER position will not change. ATTENTION: It is possible to set AUX-1 and AUX-2 to be POST-Fader or PRE-Fader.
  • Page 41 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 3.2.3 MONITORS SECTION CONTROL ROOM SPEAKER SECTION By this Speaker Monitor section you can:  adjust the output audio of the Control Room Speakers  This section is used for the management of the Control Room Speakers, by default set on ANALOG-OUT-2.
  • Page 42 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG  To unmute the speaker �� just press their knob or increase/decrease the audio level by rotating the knob.  The Control Room Speakers level is displayed in the bottom-right section of the HDMI output screen: By remoter side you can change the same parameter by the following squared controller:...
  • Page 43 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG  check the CUT mode indicator: o if SPK button is red, the Control Room speakers are currently in CUT mode with a MIC By remoter side you will have the following state: o if SPK button is green, the Control Room speakers are NOT currently in CUT mode with a MIC.
  • Page 44 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 3.2.4 MONITOR HEADPHONES CONTROLS Connect the Control Room Headphones in the female Jack 6,5 mm connector below: The connector is in parallel with the following one in the back panel: Adjust the Control Room Heaphones by the following knob controller.
  • Page 45 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG  To unmute the Headphones just press their knob or increase/decrease the audio level by rotating the knob.  The Control Room Heaphones level is displayed in the bottom-right section of the HDMI output screen: By remoter side you can change the same parameter by the following squared controller:...
  • Page 46 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG CONTROL ROOM SPEAKERS / MODE SETUP / AUDIO / OUTPUTS / MONITOR / SPEAKER / SPK-CRM / MODE MODE: 1SEL, 1SEL+PFL, 2SEL or 2SEL+PFL PFL (pre-fader listening): This mode allows you to listen in speakers to the audio of the single-channel before the intervention of the fader.
  • Page 47 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 2SEL+PFL: This mode allows you to listen to ONE selected output (PGM, SUB, EXT) in SPK-CRM, and by pressing the SPK button you will be able to select a different output to be listen on HDP-CRM. You will listen PFL if PFL button is pressed in a channel.
  • Page 48 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG When you open the associated source with a CUT function you will see it will MUTE CR Loudspeakers output to prevent LOOP audio and the SPEAKER icon at LCD will start blinking. ATT.
  • Page 49 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG CONTROL ROOM HEADPHONES / MODE SETUP / AUDIO / OUTPUTS / MONITOR / HEADPHONES / HDP-CRM / MODE MODE: SEL, SEL+PFL PFL (pre-fader listening): This mode allows you to listen in headphones to the audio of the PFL-channel before the intervention of the fader.
  • Page 50 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG SEL+PFL: This mode allows you to listen to ONE selected output or PFL if the PFL button is pressed in a channel. 2SEL (two selection): This option allows you to listen to ONE selected output (PGM, SUB, EXT, AUX1, AUX2 only by Oxygen Remoter) in SPK-STUDIO, and by pressing the button you will be able to select a different output to be listen on HDP-STUDIO.
  • Page 51 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG STUDIO SPEAKERS / CUT-ATT-MODE SETUP / AUDIO / OUTPUTS / MONITOR / SPEAKER / SPK-STUDIO / CUT-ATT-MODE CUT MODE: it’s allowed the microphone to CUT OFF the audio of control room loudspeakers once the microphone goes to ON.
  • Page 52 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG On the other hand, if you need to MUTE the just PRESS the following button: PRESS the MUTE button a second time to activate the loudspeakers output and amplification or attenuation.
  • Page 53 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG STUDIO HEADPHONES / MODE SETUP / AUDIO / OUTPUTS / MONITOR / HEADPHONES / HDP-STUDIO / MODE MODE: SEL, SEL+PFL PFL (pre-fader listening): This mode allows you to listen in headphones to the audio of the PFL-channel before the intervention of the fader.
  • Page 54 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 3.2.5 BLUETOOTH BUTTON BLUETOOTH ACTIVATOR The Bluetooth has two functioning ways: Microphone TX(Mono)- RX(Mono) Interface for telephone communication (GSM call, Skype, FaceTime, WhatsApp, Facebook, Etc.) RX (Stereo) interface for file/streaming player… The device is in pairing mode after a fast press (<...
  • Page 55 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG If you turn on again the Bluetooth in the device and if the device is still associated with the console, it will be automatically paired. You will see a fixed blue light. The console is included RN52 Bluetooth Audio Module.
  • Page 56: Oxygen Remoter - Settings

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 4. OXYGEN REMOTER - SETTINGS 4.1 OXYGEN REMOTER SIDE – ON BUTTON ON button enables or disables the channel (ON/OFF: 1) LED OFF - OFF status 2) LED ON - ON status – the channel is OPEN. 3) LED MUTE in (MUTE color) –...
  • Page 57: Special Oxygen Remoter Function Buttons

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 4.2 SPECIAL OXYGEN REMOTER FUNCTION BUTTONS OUT SET Inside the Oxygen Remoter button, the OUTSET button recalls directly the OUTPUTS configuration menu. This button is a SHORTCUT to reach immediately the SETUP / AUDIO / OUTPUTS menu.
  • Page 58 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG All the selectable OUTPUTS are described in following scheme: OXYGEN REMOTER - SETTINGS|SPECIAL OXYGEN REMOTER FUNCTION BUTTONS...
  • Page 59 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG VU SET The VU SET button manages the source displayed in the OXYGEN REMOTER section of the LED METER screen. By pressing VU SET, you can select the displayed BUS. The repeated pressing of the METER button switches the 4 BUS and the MONITOR SELECTION, sequentially displaying them.
  • Page 60 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG The selected source in HDP C-ROOM is being displayed in the MONITOR SELECTION status. In this case, all 4 LEDs are OFF as explained in the following picture. TELEPHONE (TEL – OXYGEN REMOTER SIDE) This button has the same functionality as the F1 button in telephone channel.
  • Page 61 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG The device is in pairing mode after a fast press (< 1 sec) of the Bluetooth button or after a fast pressure of the button on Oxygen Remoter. It starts to blink in blue color. search for the Oxygen 1000D-XXXX (in case of an Oxygen 1000) or Oxygen 2000D-XXXX (in case of an Oxygen 2000) in Bluetooth device and connect with it.
  • Page 62: Monitors Section

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG If you turn on again the Bluetooth in the device and if the device is still associated with the console, it will be automatically paired. You will see a fixed blue light. The console is included RN52 Bluetooth Audio Module.
  • Page 63 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG CONTROL ROOM SPEAKERS (SPK-CRM)  This section is used for the management of the CONTROL ROOM SPEAKERS  to amplify/attenuate By the mouse you can move the rotary control knobs the audio level.
  • Page 64 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG The status of MUTE-SPK-CRM is indicated by the following MUTE label on the bottom-right of the HDMI display: CONTROL ROOM HEADPHONES (HDP-CRM)  This section is used for the management of the �� CONTROL ROOM HEADPHONES.
  • Page 65 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG  To unmute the headphones �� just press again on or increase/decrease again the audio level by rotating the related surface control and confirm that by clicking on the same knob. ...
  • Page 66 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG STUDIO SPEAKERS (SPK-STD)  This section is used for the management of the STUDIO SPEAKERS  allow you to By the mouse you can move the rotary control knobs amplify/attenuate the audio level. ...
  • Page 67 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG The status of MUTE-SPK-CRM is indicated by the following MUTE label on the bottom-right of the HDMI display: STUDIO HEADPHONES (HDP-STD)  This section is used for the management of the HDP-STUDIO headphones ��.
  • Page 68 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG TALKBACK – FROM CONTROL ROOM TO THE STUDIO TALKBACK SETUP / AUDIO / OUTPUTS / MONITOR / SPEAKER / SPK-CRM / TALK BACK (OFF, ON) Here you can disable/enable the TALKBACK communications in control room speakers. Normally the talkback is used to communicate between the mixer man and the people in the studio via headphones.
  • Page 69: Smart Key / Jingle Buttons

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 4.3 SMART KEY / JINGLE BUTTONS* Smart Keys are buttons to which external functions can be associated with the mixer. They could be used as:  Keys of the Jingle Machine of the - DjPro. ...
  • Page 70: Telephone Lines Usage And Connections

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5. TELEPHONE LINES USAGE AND CONNECTIONS The console could manage 3 PHONE CALLS mode:  INTEGRATED HYBRID LINE  EXTERNAL TELCO DEVICE  EXTERNAL BLUETOOTH DEVICE 5.1 INTEGRATED HYBRID LINE You can directly connect a POTS/PSTN phone line to the OXYGEN back panel through the RJ11 connector called TELEPHONE LINE.
  • Page 71: External Telco Device

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5.2 EXTERNAL TELCO DEVICE A phonecall could be managed by an external TELCO DEVICE. To use the device with the console you have only to connect one RJ45 connector to the related port labeled as TELCO I/O GPIO.
  • Page 72 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5.2.1 TELCO 1 GPIO SETTINGS The GPIO settings for this primary TELCO device are settable by this OXYGEN REMOTER sub menu SETUP / GENERAL / GPIO To manage TELCO 1 GPI signal set the TELCO 1 RING by the following submenu: SETUP / GENERAL / GPIO / GPI / TELCO 1 To manage TELCO 1 GPO signal set the TELCO 1 HOOK by the following submenu: SETUP / GENERAL / GPIO / GPO / TELCO 1...
  • Page 73 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5.2.2 ADDITIONAL TELCO LINES It is possible to use 4 more additional TELCO lines (TELCO 2 / TELCO 3 / TELCO 4 / TELCO 5) by setting the console with the correct parameters. The following F1 MODE parameter could be set individually for each additional TELCO, in this example we are showing you the correct setting for TELCO 2: SETUP / AUDIO / INPUTS / TEL/BT / TELCO 2 / GENERAL / F1 MODE = TELEPHONE...
  • Page 74 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5.2.4 ADDITIONAL TELCO OUTPUT LINES (clienfield / N-1 logic) OUT-2 (ANALOG-OUT-2) source could be configured as 2 different TELCO mono outputs: TELCO 2: ANALOG-OUT-2-L TELCO 3: ANALOG-OUT-2-R to use the 2 above signals as 2 separate telco output lines please set the related parameter as follow: MAIN/AUDIO/OUTPUTS/ANALOG/OUT-2/ source = N-1 T2/T3 ...
  • Page 75 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5.2.5 USABLE GPIO FOR THE ADDITIONAL TELCO LINES If the GPIO port is not already used, it is possible to implement a GPIO communication with all of the additional external TELCO devices by using the GPIO port. The SUB-D9 pin-out is described into the +188-OXY1000/OXY2000-RJ45-TELCO scheme in PINOUT OF CONNECTIONS chapter, resumed by the picture below: For each available GPIs you can asisgn the RING signal for the desired additional TELCO line by the...
  • Page 76 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG We have taken GPO 1 as example, but you are free to decide what happens on each available signal (GPO 1, GPO 2, GPO 3, GPO 4): SETUP / GENERAL / GPIO / GPO TELEPHONE LINES USAGE AND CONNECTIONS|EXTERNAL TELCO DEVICE...
  • Page 77: External Bluetooth Device

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 5.3 EXTERNAL BLUETOOTH DEVICE The console allows you to pair an external bluetooth device for the following 2 excluding purposes: Microphone TX(Mono)- RX(Mono) Interface for telephone communication (GSM call, Skype, FaceTime, WhatsApp, Facebook, Etc.) RX (Stereo) interface for file/streaming player…...
  • Page 78 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG The F1 button for the channel in which you have assigned the BLUETOOTH source works differently from the other TELEPHONE sources (intenal TELEPHONE and external TELCOs). The HOOK/DROP function has to be done by the external mobile device. By F1 you only allow the audio signal forwarding to the same console channel.
  • Page 79: Compressor

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 6. COMPRESSOR: Into the OXYGEN REMOTER control software, the COMPRESSOR section of each MIC/MONO source into, let you manage all of their signal DYNAMIC aspects. Into each MIC/MONO settings you will find the related parameters.
  • Page 80 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG COMPRESSOR and LIMITER will only act on the considered values, the once higher than the currently set EXPANDER THRESHOLD. COMPRESSOR The COMPRESSOR reduces the sound DYNAMIC RANGE. The COMPRESSOR THRESHOLD defines a maximum dB value at which all the considered signal must be kept down and compressed.
  • Page 81: Ducking

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 7. DUCKING: In a musical program it happens to have the music mixed with a speech. While the anchorman or also guests are speaking you can automatically reduce the music level by this DUCKING function. The background music level is lowered.
  • Page 82 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG  On the sources desired as SLAVE, set MASTER MODE = OFF and SLAVE MODE = ON DUCKING:|EXTERNAL BLUETOOTH DEVICE...
  • Page 83: Additional Virtual Channels

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 8. ADDITIONAL VIRTUAL CHANNELS ADDITIONAL VIRTUAL CHANNELS allow you to add up to 8 virtual channels to your physical ones. To do that you have to set the ENABLE VIRTUAL CHANNELS parameter as follow: SETUP / AUDIO / SETTINGS / ENABLE VIRTUAL CHANNELS = ON After the previous parameter was correctly set, you will see a button appearing at the right of your...
  • Page 84 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG By pressing it you will add one Virtual channel manageable by OXYGEN REMOTER and not manageable by the console surface: The Virtual Channels settings and workflow are exactly the same of the other default channels. ADDITIONAL VIRTUAL CHANNELS|EXTERNAL BLUETOOTH DEVICE...
  • Page 85: Hdmi Output - Displaying Mode

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 9. HDMI OUTPUT – DISPLAYING MODE By connecting an HDMI screen to the console's HDMI port, it is possible to have a general view of the current general status of the mixer in real time in a compact and beautifully designed display. The following picture is the HDMI OUTPUT: 1.
  • Page 86: Hdmi Output - Navigation Mode

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG HDMI OUTPUT – NAVIGATION MODE Oxygen 1000 & Oxygen 2000 let you navigate through the setting menus also by the external plugged HDMI screen. 10.1 NAVIGATION MODE - ACTIVATION The HDMI menu navigation has to be activated as a console SPECIAL MODE, by pressing the following 4 last right knobs simultaneously.
  • Page 87 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG OXYGEN 2000 – HDMI - NAVIGATION MODE– ACTIVATION Simultaneous pressure of the GAIN knobs on the OXYGEN 2000 to activate the HDMI MENU NAVIGATION:  CHANNEL-9 GAIN - pressure  CHANNEL-10 GAIN - pressure ...
  • Page 88 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG 10.1.1 BROWSING CONTROLS FOR THE HDMI - NAVIGATION MODE After the special mode was successfully activated, you will be able to move into all of your console menu pages and subsections by the same previously specified GAIN KNOBS and the related F1 BUTTONS as described by the following 2 pictures: GENERAL NAVIGATION BUTTONS Some menu needs more than a page to show you all the settable parameters and by...
  • Page 89 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG In the picture below you can see the current page index: you are currently at page 1 of the 2 availables: By pressing: You will skip on page 2 of the 2 availables as described by the squared index below: NB: the repeated pressure of the ESC button will take you again on the HDMI OUTPUT –...
  • Page 90 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG POSSIBLE CONTROLS AND MOVEMENTS OF THE SINGLE KNOB IN THE SETTING OF THE CORRESPONDING PARAMETER As described by the previous image, rotate the related knobs to change the parameter setting and push the same knob to confirm the new value.
  • Page 91: Tech Specs

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG TECH SPECS Analog Balanced Stereo Inputs Connector XLR Balanced – EMI Suppressed Input Impedance 10Kohm Nominal Input Level (sensitivity) 0dBu Max Input Level (clipping point) +18,5dBu A/D conversion 24 bit / 48 Khz Frequency response +/-0,5dB from 20Hz to 20kHz Signal to Noise Ratio (referred to peak level)
  • Page 92 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Max Input Level (clipping point) +7dBu A/D conversion 24 bit / 48 Khz Signal to Noise Ratio (referred to peak level) >90dB THD+N <0,01% Analog Gain Adjustable +0 ÷ +60dB (3dB step) Phantom Power +48V Analog Balanced Telco Input...
  • Page 93 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Nominal Output Level 0dBu Max Output Level (clipping point) +19dBu D/A conversion 24 bit / 48 Khz Signal to Noise Ratio (referred to peak level) >90dB Stereo Separation (referred to peak level) >80dB THD+N <0,05%...
  • Page 94 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG Standard AES3 Audio Sample Rate 32/44.1/48KHz with aSRC Resolution 24 bit Dynamic Range (Converter Values) 124dB Digital Output Connector Balanced on 1 XLR – EMI Suppressed Input Impedance 110Ω Standard AES3 Audio Sample Rate 48KHz...
  • Page 95: Pinout Of Connections

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG PINOUT OF CONNECTIONS +187 - Oxy1000/Oxy2000 -RJ45-Mic PINOUT OF CONNECTIONS |NAVIGATION MODE - ACTIVATION...
  • Page 96 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG +188 - Oxy1000/Oxy2000 -RJ45-Telco |NAVIGATION MODE - ACTIVATION...
  • Page 97 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG +189 - Oxy1000/Oxy2000-RJ45-LineIn |NAVIGATION MODE - ACTIVATION...
  • Page 98 OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG +189 - Oxy1000/Oxy2000-RJ45-LineOut |NAVIGATION MODE - ACTIVATION...
  • Page 99: Weee Directive - Informativa Raee

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG WEEE DIRECTIVE – INFORMATIVA RAEE In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling.
  • Page 100: Warranty

    OXYGEN 1000 & OXYGEN 2000 · User Manual · ENG EU:n sähkö- elektroniikkalaiteromudirektiivin (2002/96/EY) mukaisesti tätä elektroniikkalaitetta ei saa laittaa lajittelemattoman yhdyskuntajätteen sekaan. Hävitä laite palauttamalla se ostopaikkaan tai viemällä se elektroniikkaromun keräyspisteeseen. De acordo com a Directiva Europeia 2002/96/EC sobre resíduos sólidos de equipamento eléctrico e electrónico (WEEE), este produto eléctrico não pode ser deitado fora juntamente com o lixo municipal indiferenciado.
  • Page 101: Oxygen 1000D - Declaration Of Conformity

    DECLARATION OF CONFORMITY Manufacturer: AXEL TECHNOLOGY S.r.l. Company title: VIA C. DI SABBIUNO 6/F - 40011 ANZOLA EMILIA - BOLOGNA ITALY DECLARES UNDER ITS OWN RESPONSIBILITY THAT THE FOLLOWING EQUIPMENT MODEL: OXYGEN 1000D DESCRIPTION: Digital Broadcast Console. IS COMPLIANT To the requirements and all characteristics enacted from Community Directive: 2014/30/UE “EMC”...
  • Page 102: Oxygen 2000D - Declaration Of Conformity

    DECLARATION OF CONFORMITY Manufacturer: AXEL TECHNOLOGY S.r.l. Company title: VIA C. DI SABBIUNO 6/F - 40011 ANZOLA EMILIA - BOLOGNA ITALY DECLARES UNDER ITS OWN RESPONSIBILITY THAT THE FOLLOWING EQUIPMENT MODEL: OXYGEN 2000D DESCRIPTION: Digital Broadcast Console. IS COMPLIANT To the requirements and all characteristics enacted from Community Directive: 2014/30/UE “EMC”...
  • Page 103: Oxygen 1000D - Dichiarazione Di Conformita

    DICHIARAZIONE DI CONFORMITA’ Nome Fabbricante: AXEL TECHNOLOGY S.r.l. Ragione Sociale: VIA C. DI SABBIUNO 6/F - 40011 ANZOLA EMILIA - BOLOGNA ITALY DICHIARA SOTTO LA PROPRIA RESPONSABILITÀ CHE IL PRODOTTO MODELLO: OXYGEN 1000D DESCRIZIONE: Console Broadcast digitale. RISPETTA i requisiti essenziali e tutte le caratteristiche richiamate dalla Direttiva comunitaria: 2014/30/UE “EMC”...
  • Page 104: Oxygen 2000D - Dichiarazione Di Conformita

    DICHIARAZIONE DI CONFORMITA’ Nome Fabbricante: AXEL TECHNOLOGY S.r.l. Ragione Sociale: VIA C. DI SABBIUNO 6/F - 40011 ANZOLA EMILIA - BOLOGNA ITALY DICHIARA SOTTO LA PROPRIA RESPONSABILITÀ CHE IL PRODOTTO MODELLO: OXYGEN 2000D DESCRIZIONE: Console Broadcast digitale. RISPETTA i requisiti essenziali e tutte le caratteristiche richiamate dalla Direttiva comunitaria: 2014/30/UE “EMC”...

This manual is also suitable for:

Oxygen2000

Table of Contents