Auto range hi-accuracy digital multimeter - usb interface (24 pages)
Summary of Contents for Edison TNC150
Page 1
16/04/2010 14:09 Page 1 ORDER CODE: EDI-315-4200K MODEL TNC150 Non-Contact Digital Tachometer OPERATING MANUAL Functions • M M e e a a s s u u r r e e : : r r p p m m a a n n d d r r p p s s . .
Page 2
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 2 C o n t e n t 1. GENERAL INSTRUCTIONS ..................2 2. TECHNICAL SPECIFICATIONS ..................3 3. DESCRIPTION ......................4 4. OPERATION INSTRUCTIONS ................5-6 5. MAINTENANCE......................6-7 6. PACK CONTENT......................7 1 . G E N E R A L I N S T R U C T I O N S Thank you for purchasing the Digital Tachometer.
Page 3
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 3 Non-Contact Digital Tachometer • If no reflective marker can be attached, it must be checked whether the reflective properties of a reflective point on the measurement object are sufficient for rpm measurement. In this case, aim at the measurement object from the vertical, and check whether a value is displayed.
Page 4
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 4 3 . D E S C R I P T I O N 3.1. Instrument Familiarisation 1 1 . . Sensor cover. 2 2 . . Photo Transistor (Laser sensor). 3 3 . . LCD display. Unit key.
Page 5
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 5 Non-Contact Digital Tachometer 4 . O p e r a t i o n I n s t r u c t i o n 1. Before you start to use the meter cut out a part of the reflective marker and attach it to the object which is under test.
Page 6
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 6 4.3. Func. key 1. When the meter is switched ‘on’ and the required unit (rps or rpm) has been set press the F F U U N N C C . . key to display the Maximum or Minimum value settings. This is acknowledged with the symbol on the LCD HOLD...
Page 7
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 7 Non-Contact Digital Tachometer 5.2. BATTERY REPLACEMENT Use the following procedure: When the battery voltage drops below the required operation range the symbol will appear on the LCD display and the battery need to be replaced. 1.
Page 8
EDI-315-4200K_Instructions.qxd 16/04/2010 14:09 Page 8 EDISON The Power Factory, PO Box 14, Wigston, Leicester, England. ISO 9001 Registered Company Edison Products are continuously being developed and improved. All details and illustrations are for guidance and may be subject to change.
Need help?
Do you have a question about the TNC150 and is the answer not in the manual?
Questions and answers