Possible Causes Of Failure - EINHELL TC-AC 190/24/8 Original Operating Instructions

Hide thumbs Also See for TC-AC 190/24/8:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16

10. Possible causes of failure

Problem
The compressor
1. No supply voltage.
does not start.
2. Insuffi cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
The compressor
1. The non-return valve leaks.
starts but there is no
pressure.
2. The seals are damaged.
3. The drain plug for condensation
The compressor
1. The hose connections have a leak.
starts, pressure is
shown on the pres-
2. A quick-lock coupling has a leak.
sure gauge, but the
tools do not start.
3. Insuffi cient pressure set on the
Anl_TC_AC_190_24_8_SPK9.indb 20
Anl_TC_AC_190_24_8_SPK9.indb 20
GB
Cause
water (11) leaks.
pressure regulator.
- 20 -
Autogoods "130"
Solution
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5° C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Increase the set pressure with the
pressure regulator.
12.07.2018 08:34:14
12.07.2018 08:34:14

Advertisement

Table of Contents
loading

This manual is also suitable for:

40.073.25

Table of Contents