Omron Microscan QX-830 User Manual

Compact industrial scanner

Advertisement

Quick Links

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution
of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business
relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components
to meet their specific needs.
With the principle of "Quality Parts,Customers Priority,Honest Operation,and Considerate Service",our business
mainly focus on the distribution of electronic components. Line cards we deal with include
Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise
IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,
and automotives areas.
We are looking forward to setting up business relationship with you and hope to provide you with the best service
and solution. Let us make a better world for our industry!
Contact us
Tel: +86-755-8981 8866 Fax: +86-755-8427 6832
Email & Skype: info@chipsmall.com Web: www.chipsmall.com
Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China
  

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QX-830 and is the answer not in the manual?

Questions and answers

Summary of Contents for Omron Microscan QX-830

  • Page 1 Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components to meet their specific needs.
  • Page 2 QX-830 Compact Industrial Scanner User Manual P/N 84-000830 Rev E...
  • Page 3 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Omron Microscan-manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Omron Microscan.
  • Page 4: Table Of Contents

    Read Cycle .................... 5-43 Symbologies ..................5-70 I/O Parameters ..................5-107 Matchcode ................... 5-168 Diagnostics ..................5-177 Chapter 6 Terminal Terminal Window ..................6-2 Find......................6-3 Send ......................6-4 Macros..................... 6-5 Terminal Window Menus ................. 6-6 QX-830 Compact Industrial Scanner User Manual...
  • Page 5 Appendix J Operating EtherNet/IP Serial Gateway Data Fields..A-102 Appendix K Allen-Bradley Version 16 PLC Setup .......A-104 Appendix L Allen-Bradley Version 20 PLC Setup .......A-118 Appendix M EIPScan Setup ..............A-125 Appendix N Interface Standards ............A-131 Appendix O Glossary of Terms ............A-132 QX-830 Compact Industrial Scanner User Manual...
  • Page 6 Introduction About the QX-830 Compact Industrial Scanner The key features of the QX-830 Compact Industrial Scanner are: • X-Mode™ symbol reconstruction and aggressive decode algorithm • Ethernet TCP/IP and EtherNet/IP™ • Ultra-high-performance processing • Real-time decoding • Green Flash performance indicator •...
  • Page 7 CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. There are no user-serviceable parts in the scanner. Opening the scanner voids the Omron Microscan Systems, Inc. warranty and could expose the user to laser diode power of up to 7mW.
  • Page 8 CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. IMPORTANT: The QX-830 is intended for connection to a UL-listed direct plug-in power unit marked Class 2 and rated 5 VDC at 3.5 Watts, or greater if using electrical accessories.
  • Page 9 Warning and Caution Summary Warning and Caution Summary (cont.) Warning Label Placement These labels are located on the QX-830 Compact Industrial Scanner. On Side Base viii QX-830 Compact Industrial Scanner User Manual...
  • Page 10 Introduction Statements of Compliance The QX-830 has been tested for compliance with FCC (Federal Communications Commission) regulations and has been found to conform to all applicable FCC Rules and Regulations. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter.
  • Page 11 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Omron Microscan will mark the products with the ‘CE’ marking that complies with the R oHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + R oHS2 = Declaration of Conformity.
  • Page 12 Step 8 Configure the Scanner....................1-11 Step 9 Save Changes in ESP ....................1-12 This section explains how to set up and test the QX-830 quickly using ESP (Easy Setup Program). Detailed setup information for installing the scanner into an application can be found in subsequent sections.
  • Page 13: Step 1 Check Hardware

    QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m 99-000020-02 Note: The QX-830 does not require an Ethernet crossover cordset, because the scanner itself performs automatic internal crossover (transmit-to-receive switching). Omron Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02).
  • Page 14: Step 2 Connect The System

    (transmit-to-receive switching). Omron Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02). • Connect the Ethernet Communication Cable from “B” on the QX-830 to the host network. • Connect the power supply to “A” on the QX-830.
  • Page 15: Step 3 Position Scanner And Symbol

    • Tip the scanner relative to the test symbol to avoid glare from specular reflection. axis Skew Bar code label Tilt axis Tilt Maximum pitch: ±50° Symbol Maximum skew: ±40° Scanner Pitch Pitch axis Scan line Scanner QX-830 Compact Industrial Scanner User Manual...
  • Page 16: Step 4 Install Esp

    Quick Start Step 4 — Install ESP ESP Software can be found on the Omron Microscan Tools Drive that is packaged with the QX-830. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.
  • Page 17: Step 5 Select Model

    1. Click the button showing the QX-830. 2. Click OK. Note: The QX-830 can also be selected by double-clicking the button showing the QX-830. 3. Click Yes when this dialog appears: Note: To select another model later, click the Switch Model button near the top of the screen or use Model >...
  • Page 18: Step 6 Connect

    Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect. QX-830 Compact Industrial Scanner User Manual...
  • Page 19 Connect (cont.) Step 6 — Connect (cont.) Ethernet TCP/IP Once the QX-830 is connected, incoming symbol data can be displayed in the Terminal, as shown below. QX-830 Compact Industrial Scanner User Manual...
  • Page 20: Step 7 Test Read Rate

    Symbol data and read rate percentage information should appear in the Symbol Information table in the bottom portion of the view. The Read Rate LEDs on the side of the QX-830 will indicate the percentage of successful decodes per second. 2. Click Stop to end the Read Rate test.
  • Page 21: Step 8 Configure The Scanner

    • Click the Utilities button to access Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, and Firmware. For further details, see Omron Microscan ESP Help in the dropdown Help menu. QX-830 Compact Industrial Scanner User Manual...
  • Page 22: Step 9 Save Changes In Esp

    • Send, No Save. Changes will be lost when power is re-applied to the scanner. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on. QX-830 Compact Industrial Scanner User Manual 1-11...
  • Page 23 Save Changes in ESP QX-830 Compact Industrial Scanner User Manual 1-12...
  • Page 24 Cycle, Symbologies, I/O Parameters, Matchcode, and Diagnostics), a Setup interface, a Terminal interface, and a Utilities interface. ESP can be used to configure the QX-830 in three different ways: • Graphic User Interfaces: Scanner settings can be configured using such point-and-click tools as buttons, spin boxes, check boxes, and drag-and-drop functions.
  • Page 25: Ez Mode

    Click Calibrate to begin the calibration routine. Calibration is explained at the left of the EZ Mode screen, and also Quick Start. Click the App Mode button to access configuration trees and other setup features. QX-830 Compact Industrial Scanner User Manual...
  • Page 26: App Mode

    EZ Mode. the Terminal view. Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, Firmware Tabbed tree Autoconnect to the controls scanner, Send and Receive command settings, and Switch Model QX-830 Compact Industrial Scanner User Manual...