Vr hid proximity reader

Advertisement

2053 Progeny VR HID Proximity Reader
Cable distance to controller
For further details and assistance contact us on 01254 883348 or email us on
Mounting
The ideal mounting position for a card reader will depend on the application and reader type. Choose a position that will be
natural for users to be able to swipe a card and then open the door, usually between 1.0 and 1.5 metres from the floor.
Determine an appropriate mounting location. The reader may be mounted to any surface, including metal. For Wood &
Metal: Drill two (2) 2 mm holes approximately 1 inch deep for mounting the reader. Use 2131,Flush Back Box or 2132
Surface Back Box.
For Brick Plaster etc: Drill and plug four holes for mounting the reader. Use 2131 Flush Back Box or 2132, Surface Back
Box.
Drill a 16 mm hole for the cable.
Secure the reader to the mounting surface.
Route the cable from the reader to the controller.
Test the operation of the reader. After completion of the test, apply the front label to hide mounting points.
Do not mount two readers back to back on either side of a wall.
It is a good idea to fully test the system before attaching the front label. The proximity reader may be mounted internally or
externally.
If the reader is being mounted externally, spread silicon compound over the terminals, after connecting and testing.
Cable Notes
Always use a screened and non twisted cables (8-core 7/0.02 mm) for card readers.
EMC & W