OSM40 High Precision Laser
INSTRUCTION MANUAL
Detection
Type
mode
OSM40-KL800CBLI 6Q12.1
Technical Specification
Electrical
Power supply
10...30VDC
Power Consumption
<1W
Measurement center distance
400mm
Measurement range
150mm~800mm
Repeatability
*1
0.5mm(150mm~400mm)
1mm (400mm~600mm)
3mm (600mm~800mm)
Linearity
±0.2%F.S.(150mm~400mm)
±0.3%F.S.(400mm~600mm )
±0.5%F.S.(600mm~800mm)
, 655nm
Light source
Red semiconductor laser 2
Beam diameter
1mm@150mm
2mm@600mm
Control output
NPN/PNP
Analog output
4~20mA
Response time
10ms/5ms/1.5ms
Environmental
Ambient temperature
-20℃ ...60℃
Ambient illuminance
under 3000lux
Protection
IP67
Mechanical
Housing material
316L
Windows material
PMMA
M12 
Connections
Connector
This is a laser product,it should be used after warming up for ten minutes.
*1:
Distance Sensor
Sensing range
Beam
Output
Connection
NPN /PNP
150mm~800mm
LASER
IOUT:4~20mA
Connector
Dimensions
G
A alarm Indicator
B Function setting key
C Function adjustment key
D
Transmitter
Receiver
E
F
M12*1 Connector
G
Display screen
Wiring diagram
1(Bn)
2(Wh)
3(Bu)
4(Bk)
5(Gy)
Harness color
Function
1
Brown
Positive power supply
White
Current output
2
3
Blue
Power negative
NPN/PNP
4
Black
5
Gray
External input
(NPN)
Wiring diagram
Wiring
diagram
M12
Fig1
(PNP)
Wiring diagram
Teaching
Sensing mode illustrate:
Preset "sensing mode setting" to the corresponding function
mode in menu.
1.Normal sensing mode
Press the TEACH Key in the sensing object present condition.
2. 1-point teaching
Press the TEACH Key in the sensing object present condition.
3. 2-point teaching
①Press the TEACH Key in the sensing object p-1 present
condition.
②Press the TEACH Key in the sensing object p-2 present
4. 3-point teaching
①Press the TEACH Key in the sensing object p-1 present
condition.
②Press the TEACH Key in the sensing object p-2 present
condition.
③Press the TEACH Key in the sensing object p-3 present
condition.
Color code
(Brown) +V
(Gray) External input
Load
+
(Black) Control output
10VDC-30VDC±10%
External
-
input
150mA MAX
(Blue) 0V
4-20mA
(White) Analog current output
Analog
input
device
Color code
(Brown) +V
(Gray) External input
+
(Black) Control output
10VDC-30VDC±10%
External
-
input
150mA MAX
Load
(Blue) 0V
(White) Analog current output
4-20mA
Analog
input
device
External connection example
Fig1
ON
Reference value
OFF
OFF
+Settings
ON
Reference value
-Settings
OFF
OFF
ON
OFF
OFF
ON
OFF
p-2
p-1
p
3
-
(p
2 + p
3)/2
-
-
p
2
-
(p
-
1 + p
-
2)/2
p
1
-

Advertisement

loading
Need help?

Need help?

Do you have a question about the OSM40 and is the answer not in the manual?

Questions and answers

Summary of Contents for elco OSM40

  • Page 1 OSM40 High Precision Laser Distance Sensor (NPN) Wiring diagram Color code INSTRUCTION MANUAL (Brown) +V Detection Type Wiring Sensing range Beam Output Connection mode diagram (Gray) External input Load (Black) Control output 10VDC-30VDC±10% External NPN /PNP OSM40-KL800CBLI 6Q12.1 150mm~800mm Fig1...
  • Page 2 1.Ranging diaplay OSM40 High Precision Laser Distance Sensor Measurement interface:Show actual measurement distance,resolution is 0.1mm,when the distance is out of detected distance,it diaplays“----”。 OPERATION GUIDE 2.Menu and key operation 2.1 Enter the menu:Long pressTEACH above 3s when it is in the measurement interface,...

This manual is also suitable for:

Osm40-kl800cbli86q12.1