INDEX MODEL # & DESCRIPTION----------------------------------------------------------------------------------------------------------page 2 INTRODUCTION------------------------------------------------------------------------------------------------------------------------page 2 INTENDED USE-------------------------------------------------------------------------------------------------------------------------page 2 CAUTION----------------------------------------------------------------------------------------------------------------------------------page 2 STANDARDS-----------------------------------------------------------------------------------------------------------------------------page 3 GENERAL WARNINGS----------------------------------------------------------------------------------------------------------------page 3 SYMBOLS---------------------------------------------------------------------------------------------------------------------------------page 3 GENERAL DESCRIPTION------------------------------------------------------------------------------------------------------------page 4-5 INSTALLATION--------------------------------------------------------------------------------------------------------------------------page 6 MATTRESS & COVER-----------------------------------------------------------------------------------------------------------------page 6 BEFORE USE----------------------------------------------------------------------------------------------------------------------------page 6 USE WARNINGS------------------------------------------------------------------------------------------------------------------------page 6-7 HOW TO USE----------------------------------------------------------------------------------------------------------------------------page 7 HOW TO USE THE CPR DEFLATOR & INFLATOR--------------------------------------------------------------------------page 7-8 STORAGE---------------------------------------------------------------------------------------------------------------------------------page 9 MAINTENANCE--------------------------------------------------------------------------------------------------------------------------page 9 CLEANING AND DISINFECTION---------------------------------------------------------------------------------------------------page 9...
Only qualified personnel trained in the treatment and prevention of bedsores should operate this device. • MedaCure Inc. declines all liability for any consequences resulting from incorrect use of this product and • from unauthorized alteration to the frame of the product.
STANDARDS The system has been tested and successfully approved to the following standards: EN 60601-1 EN 60601-1-1-2 GENERAL WARNINGS Keep this manual in a safe place and refer to the manual before use and under proper medical supervision. Improper operation of this system may cause damage t o the product and possible injury to the user.
GENERAL DESCRIPTION Pump and Mattress Controls and Features Main Control Panel POWER SWITCH CYCLE TIME When LED is illuminated the power is on. Adjust the cycle time from 10,15, 20 and 25 minutes for “Alternating”...
Page 6
Front (1) Control panel (2) Female quick connector (3) Male quick connector (4) Main male quick connector (5) Fuse Back (8) Filter (9) Main filter (10) Protective cap of filter (11) Hook (1) Pillow (2) Cover (3) Fixing belt (4) Low air loss holes (5) Male quick connector (6) Protective cap of connector (7) Air tubing...
INSTALLATION 1.Comfort Zone is a replacement mattress. Place the mattress directly on the bed frame, with the air hose connectors positioned at the footboard. 2.Hang the pump onto the bed board (footboard side) using the hooks on back of the pump, or place it on a flat surface. 3.Connect air hose connectors from air mattress to the pump unit.
1) Only use the system under the supervision of a nurse or caregiver that understands how to operate this device. 2) Do not use any parts that did not come with this unit or supplied by MedaCure or authorized dealer.
Page 9
2) Pull down tab to open the valve as shown. IMPORTANT: Always keep this tab in the closed position when mattress is in use to prevent deflating. 3) Turn the CPR as show to open the valve for deflating. 4) Align the air holes as shown to deflate. CPR Inflator –...
Dispose this equipment by bringing it to a specific recycling point for electric and electronic equipment or others that provide this service. SPARE PARTS/ACCESSORIES For spare parts and accessories please contact MedaCure or authorized dealer. TROUBLESHOOTING If your questions can’t be answered with below information, please contact your local agent directly. They might require a technician to take care of the problem.
ELECTROMAGNETIC COMPATIBILITY DECLARATION Guidance and manufacturer’s declaration-electromagnetic emissions The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance RF emissions...
Page 12
ELECTROMAGNETIC COMPATIBILITY DECLARATION Guidance and manufacturer’s declaration-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Immunity test IEC 60601 Compliance level Electromagnetic...
Page 13
ELECTROMAGNETIC COMPATIBILITY DECLARATION Guidance and manufacturer’s declaration-electromagnetic immunity The CZ36 & CZ36-BIP is intended for use in the electromagnetic environment specified below. The customer or the user of the CZ36 & CA36-BIP should ensure that it is used in such an environment. Immunity test IEC 60601 test Compliance...
Page 14
ELECTROMAGNETIC COMPATIBILITY DECLARATION Recommended separation distance between portable and mobile RF communications equipment and the CZ36 & CZ36-BIP The CZ36 & CZ36-BIP is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the CZ36 & CZ36-BIP can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the CZ36 &...
APPENDIX--- BUILT-IN AIR PERIMETER MATTRESS MODEL # CZ36-BIP THIS MODEL COMES WITH A BUILT-IN AIR PERIMETER PLEASE CHECK THE BACK OF THE PUMP FOR CORRECT MODEL NUMBER. The built in air perimeters are located on both the left & right side of the mattress. This prevents the patient’s arms and legs from getting caught in between the air mattress and side rail.