SETTINGS MENU
Adjust the settings for the M3i+ unit in the mobile app or online, in order to change
the settings, the device must be online. Below are system and test settings that you
can change if you wish. Factory default settings have been underlined.
General
Startup mode
Indicates the start mode of the device
after it has been without power.
Sound alert
Indicates situations when the device
sounds an alarm.
Silent time
Indicates when the device is silent.
Sleep length
The pre-set default time frame of the Pause mode.
Time zone
Time zone settings.
Close valve in away mode The valve is closed when the unit is put into
Away mode.
Flow test (FT)
Enabled
Enables or disables the flow test.
FT duration Away
The Away mode allows the magnetic valve to
close. It activates the alarm after the water has
flown longer than the set time of flow.
FT duration Home
Indicates the time that the flow of water is allowed
in Home mode before the flow alarm sounds. The
Home mode allows the magnetic valve to close if
the water flow continues after the set time.
FT alarm delay
Indicates the additional time that the flow
of water is allowed in Home mode before
the valve closes.
Volume test (VT)
Max flow rate
Indicates how much flow is allowed before
Volume Test Warning is given.
Daily volume
Indicates the maximum allowed volume of
water that can be tapped per day before the
Volume Test warning is given.
Hourly volume
Indicates the maximum allowed volume of
water that can be tapped per hour before the
Volume Test warning is given.
Tightness test (TT)
Enabled
Enables or disables the tightness test.
8
Sensitivity
TT alarm delay
Pressure test duration
Home/
Pressure tests/day
Away/
Last
Pressure tests before
Disabled/
action
Alarm/
Always
Input handling
23:00–07:00
AUX1 in
1–24 hours
(3)
WET/CET/EET
Yes/No
AUX1 active
Yes/No
1–999 s
AUX2 in
(1)
1–240 min
AUX2 active
(20)
Output handling
AUX out active
0–240 min
(5)
AUX event trigger
l/min
l/day
Freeze guard
l/h
Alarm level
Alarm limit
Yes/No
High sensitivity reacts at lower pressure drops.
Should be adjusted to the size of the property.
When the tightness test alarm sounds, you can
set an additional time that indicates how long the
alarm is allowed to sound before the valve closes.
Specifies how long a pressure test should last.
Number of pressure tests per day.
Specifies the number of consecutive pressure test
periods that may fail before a warning occurs.
Indicates whether you prefer to switch
between the Home mode and the Away mode
with a separate button or with the burglar
alarm. In other cases the input can be set in a
way that the warning or alarm shows on an ex-
ternal device, i.e. Moisture sensor, thermostat
or pressure sensor. If it is set on "Deactivated",
no activity will be registered through this input.
Indicates whether the input will be
activated when it is high or low.
Indicates the operation of the AUX2 connection.
See previous description of AUX1.
Indicates whether the input will be activated
when it is high or low.
Specifies whether the AUX output should close
or open when activated. If "Off" is selected,
the output is not activated at events.
Specifies whether the output should be
activated when the unit is in the Away state
or when it is in Home mode. Alternatively,
it can be chosen that it should instead be
activated in the event of warnings or in
the event of an alarm.
Type of alarm given when the alarm limit
is reached.
Alarms if the temperature drops below this
limit. Resets when the temperature rises
2 degrees.
Low/
Medium/
High
0–7 days
(1)
1–60 min
(20)
1–12
(1)
1–4
(1)
Disabled/
Home/
Away/
Warning/
Alarm
High/Low
Disabled/
Home/Away/
Warning/
Alarm
High/Low
Disabled/
Open/
Closed
Home/
Away/
Warning/
Alarm
Disabled/
Warning/
Alarm
1-25
(3)
9

Advertisement

Table of Contents
loading

Related Products for Leakomatic M3i+

Table of Contents