Disposal The ML1018 Measuring Lance must be disposed of in accordance with applicable regulations. Some of the components used in the devices can cause damage to the environment if incorrectly disposed.
WEEE INFORMATION „Umsetzung der Richtlinie 2012/19/EU über “Implementation of Directive 2012/19/EU on Elektro- und Elektronik-Altgeräte (EEA)“ waste electrical and electronic equip¬ment Das Symbol der durchgekreuzten Mülltonne auf (WEEE)” dem Gerät oder der Geräteverpackung weist da- The symbol showing a crossed-out wheeled bin rauf hin, dass Sie das Produkt am Ende seines on equipment or its packaging indicates that the Lebenszyklus separat entsor¬gen müssen.
1� GENERAL DESCRIPTION 1�1� Profile The measuring-lance ML1018 is inserted into a borehole then pressed so hard onto wall of the hole that friction in a tie bar and then preloaded to measure the strain at replaces the bonding normally used to fix strain gauges.
1�3� ML1018 Measuring Lance Main features • Measure strain in deep holes • With calibrated digital amplifier • Quick and easy mounting with torque-wrench • High linearity on tension and compression • For dynamic applications • Used in injection moulding and die-casting machines or any cylinder •...
2� INSTALLATION Warning! The installation of the devices described in the manual must be carried out by qua- lified personnel, following the laws and regulations and in accordance with the instructions contained in this manual. Warning! Do not open the device when the power is on. Warning! Use extreme caution when installing and fixing the sensor unit.
2�3� Assembly • Avoid contamination from grease or oil on the sensor tip. • Don‘t touch the sensor tip with bare hands. • The measuring lance housing must not rest against the workpiece. • The sealing ring (Ø16mm) or the support ring (Ø20mm) must be inside the borehole. •...
Reset Green Reset Yellow Signal output Grey Signal ground Blue Power ground Pink 2�5� Reset function ML1018 Non isolated reset Controller Power 20…28V Reset Reset switch Reset (24V Signal output (+) ± 10V Signal ground (-) Power ground ML1018...
3� OPERATIONS 3�1� Measurement procedure • Before starting to measure, three cycles at fullscale must be run. • To avoid measuring errors SENSORMATE AG recom- mends to reset the zero point after each machine cycle. Reset > 25ms 4� DISMANTLING...
6�2� Servicing In order to guarantee a faultless operation of the measu- ring lance, it is recommended to have repair work carried out only by Sensormate AG. 12 / 16 Subject to technical modifications...
1000 με Features Example: ML1018 - 20 - 0650 - 0500 - O Measuring lance type ML1018, Borehole diameter X = 20 mm, Lance lenght Y = 650 mm, Measuring range = 500με, No features 14 / 16 Subject to technical modifications...
Page 15
Notes: 15 / 16 Subject to technical modifications...