Remote (Track Side) Snow Sensor; Fault And Power-On Indication Lights; Height Adjustment Legs - Spectrum RRSHA3 Series User Manual

Track switch hot air blower
Table of Contents

Advertisement

RRSHA Series Hot Air Blower User Manual
5. Connect the cables for the optional equipment inside the Wiring Box.

2.3.2 Remote (track side) Snow Sensor

If ordered for the RRSHA series hot air blower the Remote Snow Sensor has four wires that should
be connected as follows:
Yellow to TB1-1
Yellow to TB1-3
Black or Brown to TB1-1
White or Blue to TB1-2

2.3.3 Fault and Power-On Indication Lights

When purchased as integral to the RRSHA series heater use model Suffix "P1" and/or Suffix "P2".
If purchased separately, contact Spectrum for installation instructions.

2.3.4 Height Adjustment Legs

When purchased as integral to the RRSHA series heater use model Suffix "M"
If purchased separately, contact Spectrum for installation instructions.
Fig. 40
Wiring Box and
Wiring Box Post Installation
ENM-3600-00