EV-04 Personal Mobile Alarm System
Reference Manual
EV-04_RM_EN_V1.1_ 2021.12
en
Reference Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TeleAlarm EV-04 and is the answer not in the manual?

Questions and answers

Summary of Contents for KATEK TeleAlarm EV-04

  • Page 1 EV-04 Personal Mobile Alarm System Reference Manual EV-04_RM_EN_V1.1_ 2021.12 Reference Manual...
  • Page 2 THIS PAGE IS LEFT INTENTIONALLY BLANK...
  • Page 3: Table Of Contents

    EV-04 Reference Manual Table of contents | en Table of contents General description ............3 Used warnings and symbols ............3 Presentation of the whole system ..........3 EV-04 Personal Mobile Alarm System – Setup ......4 Charging base DS3 – Setup ............4 ParamEdit software ............
  • Page 4: General Description

    EV-04 Reference Manual General description | en General description Used warnings and symbols Depending on the hazard level, the warnings and notes used in this manual have the following meaning: NOTICE Means that damage to the equipment or an undesired condition may occur if the recommended precautions are not taken.
  • Page 5: Personal Mobile Alarm System - Setup

    en | General description EV-04 Reference Manual EV-04 Personal Mobile Alarm System – Setup Warning Remove the SIM card password beforehand, using a mobile phone. 1. Insert the nano SIM card into the EV-04. 2. Connect the charging base DS3 to your computer by USB. 3.
  • Page 6: Paramedit Software

    EV-04 Reference Manual ParamEdit software | en ParamEdit software “System Info” tab Password (for SMS Command) Set this parameter to ON and define a password to protect the unit against unwanted modification. Time Zone Set the current local time. E.g. Central European Time (CET: UTC+01:00), Western European Time (WET: UTC00:00).
  • Page 7: Contact Number" Tab

    en | ParamEdit software EV-04 Reference Manual “Contact Number” tab A1 to A10 Call up to 10 recipients. Receive SMS Select to receive SMS messages. Receive Call Select to receive phone calls. Switch Turn on to activate the recipient. © TeleAlarm SA EV-04_RM_EN_V1.1_ 2021.12_Final...
  • Page 8: Tracking Settings" Tab

    EV-04 Reference Manual ParamEdit software | en “Tracking Settings” tab The information “Unit: S/M/H” must be set in seconds. Working Mode To select tracking mode. – ► Mode 1 Energy saving mode: The device only sends data to the server and enables the GPS/WiFi/BLE when an event occurs (e.g.
  • Page 9 en | ParamEdit software EV-04 Reference Manual – ► Mode 4 Data savings: The device connects the server only at a defined time interval. The user needs to set reporting time to the server. GPS/WiFi/BLE are only enabled when data are sent. –...
  • Page 10: Buttons/Phone Settings" Tab

    EV-04 Reference Manual ParamEdit software | en “Buttons/Phone Settings” tab The information “Press Unit: 0.1s” must be set in tenths of a second. The information “Unit: S/M/H” must be set in seconds. Buttons Define “SOS” and “CALL 1” buttons behaviour. 1.
  • Page 11 en | ParamEdit software EV-04 Reference Manual "After press SOS" Ring time: The time that passes from the time an outgoing call is initiated until the called party answers the call. After this time, if the recipient did not answer, the device will call the next recipient.
  • Page 12: Function Settings" Tab

    EV-04 Reference Manual ParamEdit software | en “Functions Settings” tab Phone Option Define the phone behaviour. 1. How to answer incoming calls. 2. Which numbers are allowed to call in (authorized numbers means the numbers defined in the “Contact Number” tab). 3.
  • Page 13 SMS. In that case, please turn on "long SMS" to solve this issue. 15. LT: Deactivated in the TeleAlarm EV-04 to protect yourself from unethical or illegal spying. © TeleAlarm SA...
  • Page 14: Alert Settings" Tab

    EV-04 Reference Manual ParamEdit software | en “Alert Settings” tab Geo-fence (GEO NO.1 to GEO NO.4) Define a virtual geographic boundary that enables the device to trigger an alarm when it enters or leaves a particular area. Over Speed Alert when the speed is higher than a certain value. Tilt Alert Alert when the device is tilted more than a defined tilt, at least for a defined time.
  • Page 15 en | ParamEdit software EV-04 Reference Manual Low Power Alert Alert when power is less than a defined percentage. Power ON Alert when power on. Power OFF Alert when power off. © TeleAlarm SA EV-04_RM_EN_V1.1_ 2021.12_Final...
  • Page 16: Alarm Clock" Tab

    EV-04 Reference Manual ParamEdit software | en “Alarm Clock” tab This function can be used to set reminders (local alarms) at a certain time with a specific ring tone. EV-04_RM_EN_V1.1_ 2021.12_Final © TeleAlarm SA...
  • Page 17: Voice Prompt Setting" Tab

    en | ParamEdit software EV-04 Reference Manual “Voice Prompt Setting” tab To enable/disable synthetic voice messages. © TeleAlarm SA EV-04_RM_EN_V1.1_ 2021.12_Final...
  • Page 18: Beacon Setting" Tab

    EV-04 Reference Manual ParamEdit software | en “Beacon Setting” tab This function can be used to define the location of the beacons. The "Scan" button helps to search for beacons. EV-04_RM_EN_V1.1_ 2021.12_Final © TeleAlarm SA...
  • Page 19: Wifi Setting" Tab

    en | ParamEdit software EV-04 Reference Manual 2.10 “WiFi Setting” tab This function can be used to connect the EV-04 to home WiFi. When connected, the device automatically switches off its GPS, for energy-saving purposes. © TeleAlarm SA EV-04_RM_EN_V1.1_ 2021.12_Final...
  • Page 20: Home Wifi" Tab

    EV-04 Reference Manual ParamEdit software | en 2.11 “Home WiFi” tab To use WiFi as a beacon. ► Use the Scan button (not “Scan auto” – if “Scan auto” has been used, clear the data, and save). ► Scan, select a WiFi and click Add. ►...
  • Page 21 en | ParamEdit software EV-04 Reference Manual THIS PAGE IS LEFT INTENTIONALLY BLANK © TeleAlarm SA EV-04_RM_EN_V1.1_ 2021.12_Final...
  • Page 22 TeleAlarm SA Rue du Pont 23 2300 La Chaux-de-Fonds Switzerland www.telealarm.com © Copyright TeleAlarm SA, 2021 TeleAlarm Europe GmbH Hertzstraße 2 04329 Leipzig Germany Contact in UK Tel: +44 (0) 333 0124392 info-uk@telealarm.com...