A2T NT-120S Operating Manual

Rfid card access control

Advertisement

Quick Links

RFID Card Access Control
Operating Manual
(Please read operating maual carefully before use)
Please keep the operating manual carefully

Advertisement

Table of Contents
loading

Summary of Contents for A2T NT-120S

  • Page 1 RFID Card Access Control Operating Manual (Please read operating maual carefully before use) Please keep the operating manual carefully...
  • Page 2: Table Of Contents

    Contents Product main technical Specification Factory defaults Sound and Light show Cancel command Functions and settings programming Restore factory default User’s instruction Reset programming pin Warning output Frequently asked questions...
  • Page 3: Product Main Technical Specification

    1.Product main technical Specification Item Specification Voltage 12VDC+12%/1.2A Lock Relay 12VDC/1.2A Environmeantal Working:0°C~45°C temperature Storage:-10°C~55°C Working:40%~90%RH Relative humidity Storage:20%~90%RH Cards Capacity 1000 Public PIN: 1 Pin Capacity Private PIN: 1000 Internal reader ID Model:125KHz frequency IC Model:13.56MHz ID Model: EM or compatible Proximity Card IC Model: MF 1 or compatible Card reader...
  • Page 4: Factory Defaults

    2.Factory defaults Item Factory default 881,122(recommends user Programming PIN modified) Door open mode card or public pin(1234) Private PIN 0000 Unlock time 3 seconds Anti-break Alarm Open Magnetic Alarm Lock status Alarm delay 0 seconds Modify Private PIN 3.Sound and Light show 3.1: Normal working condition 3.1.1.
  • Page 5: Functions And Settings Programming

    5.Functions and settings programming 5.1 Enter the programming mode Press [#] + [ 6-digit pin](default: 881, 122) 5.2 Modify the programming PIN: Press [0] + [new 6-digit pin] + [confirm the news 6-digit pin] 5.3 Eroll card: Press [5] + [3-digit index code] (2 beeps) + [card 1] (beep,2 beeps) + [card 2] (beep, 2 beeps) + ...
  • Page 6 5.4 Delete card: 5.4.1. Delete by index Card: Press [7] + [3-digit code 1] (2 beeps) + [3-digit code 2] (2 beeps) + ..+ [3-digit code n] (2 beeps) + [#] (2 beeps) complete the delete cards 5.4.2. Delete by presenting cards: Press [7] + [proximity code 1] (beep, 2 beeps) + [proximity code 2] (beep, 2 beeps)
  • Page 7 5.6.1. Card or pin mode: Press [1] + [0] (2 beeps) (default) 5.6.2. Card + private PIN mode: [1] + [1] (2 beeps) 5.7. Pins 5.7.1. “Card or pin” for the mode is either the public pin or private pin (up to 999) 5.7.2.
  • Page 8 5.8. Change door open time: Press [2] + [TT]. TT is the time interval is seconds. For example, if the door open time is 3 seconds, TT=3 5.9. Anti-break: 5.9.1. Disable anti-break: Press [4] + [0] 5.9.2. Enable anti-break: Press [4] + [1] 5.10.
  • Page 9: Restore Factory Default

    5.12. Alarm delay time: Press [82] + [TT] TT is the time interval in seconds. For example, if the delay time is 3 seconds, then TT=3 When door is locked TT seconds, if the door contact sensor is in alarm status, the controller is in alarm mode. This function should be used when the door sensor alarm is on.
  • Page 10: Frequently Asked Questions

    10.Frequently asked questions Symptom Possible wrongs and solutions After the lock is opened. there The controller needs higher voltage; the are 8 short beeps power supply should be checked 1.The controller puts in the metal surface, adjusts the controller position The can reading distance is 2.The electric current insufficient supply, short or card cannot be read...
  • Page 11 ACCESS CONTROL B e I I Wiegand reader input Electric lock Eiectric Lock Power ReIay Output...
  • Page 12 Professional Manufacturer ID 201201-1.0...