hilscher NFD-3090-EIS-IOLM/W User Manual

Netfield io-link wireless master ethernet/ip adapter
Table of Contents

Advertisement

Quick Links

User manual
NFD-3090-EIS-IOLM\W
netFIELD IO-Link Wireless Master EtherNet/IP Adapter
Hilscher Gesellschaft für Systemautomation mbH
www.hilscher.com
DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NFD-3090-EIS-IOLM/W and is the answer not in the manual?

Questions and answers

Summary of Contents for hilscher NFD-3090-EIS-IOLM/W

  • Page 1 User manual NFD-3090-EIS-IOLM\W netFIELD IO-Link Wireless Master EtherNet/IP Adapter Hilscher Gesellschaft für Systemautomation mbH www.hilscher.com DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 2: Table Of Contents

    Configuration with netFIELD Wireless Web Server ............ 31 8.3.1 Functional overview .................. 31 8.3.2 Open netFIELD Wireless Web Server ............ 32 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 3 Event Qualifier .................... 127 11.3.2 IO-Link Wireless Master Event Codes ............ 127 11.3.3 IO-Link Device Event Codes (common)............ 128 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 4 15.2 Conventions in this document .................. 139 15.3 Directives and standards.................... 140 15.4 Legal notes........................ 141 15.5 Registered trademarks.................... 145 Glossary.......................... 151 Contacts.......................... 154 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 5: Introduction

    Section Technical data protocol [} page 133] revised. Approvals: Chapter Approvals [} page 136] added. Appendix: Section Directives and standards [} page 140] added. Table 1: List of revisions NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 6: Device Description

    For further information see section Configuration tools [} page 23]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 7: Device Overview

    Figure 1: Device overview, NFD-3090-EIS-IOLM\W Manufacturer, product identification, and technical data can be found on the device housing as laser engravings. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 8: Table 2: Legend To The Device Overview, Nfd-3090-Eis-Iolm\W

    Mounting hole and grounding Mounting and demounting [} page 17] (18) Mounting hole Table 2: Legend to the device overview, NFD-3090-EIS-IOLM\W NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 9: Product Software

    APP CPU. Table 5: Firmware Description Version IO-Link Wireless Master stack Radio module revision Table 6: IO-Link Wireless Master NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 10: Identification

    To find the QR code in the device overview, see position (26) in section Device overview [} page 7]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 11: Connectors And Interfaces

    Receive data positive TX– Transmit data negative RX– Receive data negative M12, D-coded, socket, 4-pin Table 8: Ethernet NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 12: Io-Link, Sma Antenna

    (T). Figure 3: Derating netFIELD IO-Link Wireless Master device NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 13: Safety

    Measurement and analysis of electrical functions and systems · Evaluation of the safety of electrical systems and equipment · Installing and configuring IT systems NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 14: Power Drop During Write And Delete Accesses In The File System

    Information and data security Take all usual measures for information and data security, in particular, for devices with Ethernet technology. Hilscher explicitly points out that a device with access to a public network (Internet) must be installed behind a firewall or only be accessible via a secure connection such as an encrypted VPN connection.
  • Page 15: Getting Started

    EtherNet/IP Scanner or using the netFIELD Wireless Web Server. · Configure the IO-Link Device. Table 10: Overview for installation and commissioning NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 16: Requirements

    DHCP server (at least required for first commissioning) · For further information see section Configuration tools [} page 23]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 17: Mounting And Demounting

    Mount the device so that the diagnostic LEDs of the device remain · visible. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 18 Mounting of the SMA antennas Important: For proper device operation, all three SMA antennas X1, X2, and X3 must be mounted. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 19: Grounding

    If the demounted device is defective, mark it as defective to prevent the device from being used again. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 20: Disposal Of Waste Electronic Equipment

    As a consumer, you are legally obliged to dispose of all waste electronic equipment according to national and local regulations. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 21: Connections

    Ø Connect the power cable (+24 V DC SELV or PELV) to the power connector of the W-Bridge. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 22: Connection Example

    Connections 22/154 Connection example Figure 4: Connection example with W-Bridge NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 23: Configuration

    IO-Link E.T.: The IO-Link engineering tool serves also for device configuration, and can import IODD files of the used IO-Link Devices. For the NFD-3090-EIS-IOLM\W device, the EDS file HILSCHER- NETFIELD-WIRELESS-Vx.y.EDS is available to be used in the configuration software for the EtherNet/IP Scanner for easy parameterization.
  • Page 24 If connection 1 is used, and you want to change parameters for the wireless ports permanently, set them with the configuration software of the EtherNet/ IP Scanner. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 25: Table 11: Overview Tool Chains 1 And 2

    For more details, refer to sections Configuration with netFIELD Wireless Web Server [} page 31], and Configuring EtherNet/ IP [} page 26]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 26: Configuring Ethernet/Ip

    Ø Select the netFIELD device from the device catalog and add it to the configuration project. Ø For configuration of the netFIELD device, select a connection. Ø Set the parameters. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 27: Selecting A Connection

    Input Only - 16 ports x 4 bytes Up to 16 IO-Link Devices with up to 4 IO-Link bytes and two wireless tracks can be used. Table 12: Connections NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 28: Setting Parameters

    IO-Link Device used. 15, 25, … Device ID 1 … 16777215 16777215 Table 13: Parameters 10 to 85 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 29: Table 14: Parameters 410 To 566

    “I-Am-Alive” messages to the W-Master before timeout, otherwise an error is reported, e.g. to start failsafe functionalities in the application. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 30: Table 16: Time Base Of I-Am-Alive Time

    Alive time”, the error message Port configuration failed HTTP Error 500: NetProxy returned with an error: C0000124 appears. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 31: Configuration With Netfield Wireless Web Server

    User login and logout Sign-out Table 18: Functional overview of the netFIELD Wireless Web Server for IO-Link Devices NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 32: Open Netfield Wireless Web Server

    ð The page Dashboard of the netFIELD Wireless Web Server appears. You can now use the functions described below. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 33: Dashboard

    Maintenance information tab of the Settings menu (see Maintenance information [} page 58]). NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 34: Licenses

    Each of them must be paired to one of the 16 wireless IO-Link ports (WP01, Wp02, WP03, …). NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 35: Figure 6: Channel Selection Tab

    Ø Select the operating channels required for device operation. Ø Click Apply. Ê The selected WLAN channels are configured. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 36 Ø Check Expert settings. Ê The following view appears with configuration options of each single MHz frequency. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 37: Figure 7: Channel Selection Tab, Expert Settings (Example)

    Configuration 37/154 Figure 7: Channel selection tab, Expert settings (example) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 38: Figure 8: Master > Configuration Tab

    · Roaming · Auto NOTE: Only 1 track can be in Roaming or Service mode. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 39: Table 21: Io-Link Wireless Master Settings - Configuration

    Ø Delete the Master configuration. Ø Perform a device reset. For further information, refer to Configuring the IO-Link Wireless Master [} page 73]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 40: Figure 9: Scan Tab

    This parameter is specified by the found device. It found device indicates software revision running on the found device. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 41: Table 22: Scan Result, Pairing

    . The message Unpairing succeeded appears. For further information, refer to Configuring the IO-Link Wireless Master [} page 73]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 42: Device Or Port Information

    Process Data Display of the process data (input/output) Table 23: Information, Status, Settings, ISDU, or Process Data NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 43: Figure 11: Information Tab, Device Information (Example)

    Revision of firmware in connected device in a vendor specific Character string format. (up to 64 characters) Table 24: Information tab, with Device information NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 44: Figure 12: Status Tab, Port Status (Example)

    IO-Link Device. The indicated value does not change during runtime. Table 25: Port status, overview NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 45: Table 26: Port State, Possible Values

    Cycle time fault The configured cycle time does not match the connected device. Table 26: Port state, possible values NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 46: Figure 13: Display Of The On Request Data, Read/Write Io-Link Device Parameters

    Ø Open the ISDU tab. Ê The ISDU tab is displayed. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 47 0102030405) in the Write data entry field. Ø Click on Write. Ê The write access is performed. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 48: Figure 14: Display Of The Isdu, Read/Write Io-Link Wireless Master Parameters

    Changes to settings require operator or admin rights. If these are not available, the ISDU tab is grayed out and the displayed values cannot be edited. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 49 The Time is displayed in the format HH:MM:SS PortId and ArgBlockId are displayed in hexadecimal format. · NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 50 To clear the logged history of read and write accesses: Ø Click Clear history. ð The history of read and write accesses is deleted. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 51: Device Settings

    Ø Select Sign in or User administation to access to the Log in or User administration [} page 68]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 52: Figure 16: Settings Tab, Port Cycle Sub Tab (Example)

    W-Master. The cycle time is encoded using "Time base" (bits 6+7) and "Multiplier" (bits 0-5) values, as shown in the following table: NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 53: Table 29: Calculation Of The Port Cycle Time Of The Io-Link Wireless Master

    Ø Under Validation and backup, configure possible values for the inspection level to be performed by the device and the Backup/Restore behavior. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 54: Table 31: Validation And Backup, Possible Values

    Ø If necessary, set the expected port parameters Max PD Segment Length, Slot number, Track number, Device TX power or Max retry. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 55: Table 33: Settings In Port Configuration For Io-Link Device, Miscellaneous Sub Tab

    Ø If necessary, set the expected port parameters Slot type or Low power device. Ø Configure the “IMA Time” (I-Am-Alive time). NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 56 "disconnected" state is shown, the green hook icon is still visible and reflects the latest status obtained from the device. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 57: Figure 17: Device Configuration Tab (Example)

    Gateway IP address for ETHERNET communication with static configuration of the IP address Table 35: Device configuration tab- Parameter NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 58: Figure 18: Maintenance Information Tab

    Ø Click on the Settings in the left column of the netFIELD Wireless Web Server. Ê The Device configuration tab appears. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 59: Figure 19: Firmware Update Tab (Example)

    Ø Select Settings in the left column of the netFIELD Wireless Web Server. Ø Open the Firmware update tab. Figure 19: Firmware update tab (example) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 60 Ø Select the file NFDW_Update_[protocol name]_V[version].zip in this dialog. Ø Click Update. ð The firmware update is performed. This takes a short while. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 61: Figure 20: Firmware Update Is Performed (Example)

    (possibly different) IP address. Ø Click OK. Ø Then you must perform the port configuration once again. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 62: Figure 21: Factory Reset Tab

    ð The selected settings are deleted. ð Click on Restart. ð The device is restarted with the factory settings. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 63: Figure 22: Mqtt Tab, Client Status, Client Configuration Sub Tab (Example)

    Last error code, related to this connection. Example: 0 Table 38: MQTT in port configuration for IO-Link Device, Client Status NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 64: Figure 23: Mqtt Tab, Connection1 > Ip Settings Sub Sub Tab (Example)

    Ø For MQTT Connection Configuration make the following settings and configuration steps: Broker Address · Broker Port · NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 65: Figure 24: Mqtt Tab, Connection1 > Session Settings Sub Sub Tab (Example)

    Ø For MQTT Connection Configuration make the following settings and configuration steps: · Topic Prefix · Clean Session MQTT Keep Alive Time · NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 66: Figure 25: Mqtt Tab, Connection1 > Will Settings Sub Sub Tab (Example)

    Ø For MQTT Connection Configuration make the following settings and configuration steps: · Will Enabled · Will Topic · Will Message · Will Retain NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 67: Figure 26: Mqtt Tab, Connection1 > Advanced Settings Sub Sub Tab (Example)

    Ø For MQTT Connection Configuration make the following settings and configuration steps: Will QoS · Will Prefix · Connection Timeout · · Client Identifier NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 68: Figure 27: Menu Item Signin - Input Mask For User Name And Password

    By default, the netFIELD Wireless Web Server knows a user guest without password, which has been set up to realize a first-time or guest access. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 69: Figure 28: User Administration Screen Mask (Initial State)

    Ø Finally, click on the green field. Ê The new user is created and assigned to the selected role. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 70: Figure 29: User Administration Screen Mask

    ð The user will be deleted. The “root” user cannot be deleted, so the red delete button is grayed out. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 71: Commissioning

    Ø Thereafter, start file RunStandAlone.bat. ð The DHCP server is ready for operation now. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 72: Configuration With Netfield Wireless Web Server

    A browser is required, to connect to the netFIELD Wireless Web Server. · A login as admin. · NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 73: Configuring The Io-Link Wireless Master

    For proper device operation all three tracks must be activated. Ø Click Apply. Ê The request appears Applying configuration will restart the device. Are you sure?. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 74: Figure 31: Scan Tab

    Note: For a device featuring “Double slot” an even port must be assigned. Pairing Pair (green) Table 45: Scan result Figure 32: Scan tab with result NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 75: Port Settings

    Example 2 5 ms Port cycle time = 5 ms Table 46: Settings > Port cycle (example values) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 76: Figure 34: Settings Tab > Validation Level Sub Tab (Example)

    The Vendor ID and Device ID can be taken from the IODD or the device description of the manufacturer. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 77: Figure 35: Settings Tab > Transmission Sub Tab (Example)

    Device TX power 31 = max. transmission power Maximum retry Example value Table 48: Settings > Transmission (example values) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 78: Figure 36: Settings Tab > Miscellaneous Sub Tab (Example)

    Port settings [} page 52]. For details on track and port, see Wireless [} page 84]. For the corresponding process data as result from the configuration made, see Testing [} page 79]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 79: Testing

    15 ms Signal quality 15 % Input data length 2 Bytes Table 50: Status tab, Port status, displayed values NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 80: Figure 39: Information Tab, Device Information

    IO-Link Wireless Master and the port configuration are completed. Figure 39: Information tab, Device information NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 81: Master Reset

    Ê The device reset is complete. The message Device reset successfully appears. For detailed descriptions on the firmware update page, see Firmware update [} page 59]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 82: Indexed Service Data Units

    Ø Select Master in the left column of the netFIELD Wireless Web Server. Ø Open the ISDU tab. Ø Enable Tigo Master Parameters. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 83: Figure 41: Isdu Tab, Read/Write Io-Link Wireless Master Parameters

    For detailed descriptions on the ISDU tab with option Tigo Master Parameters enabled, see Master ISDU [} page 48]. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 84: Wireless

    Chapter Setting date and time of the device via OPC UA [} page 87] describes how to set the IP address of the NTP server via an OPC UA client. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 85: Using Opc Ua Client

    Ø Use Server > Add to add a new server. Ê The tab Discovery displays the dialog Add Server. Tab Discovery (default) Tab Advanced NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 86 Ø Open the context menu of the server (Test) and select Connect. ð The connection will be established. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 87: Setting Date And Time Of The Device Via Opc Ua

    Root> Objects> DeviceSet> [Device name] > Configuration> NtpClient> NtpClientUpdateConfiguration. Figure 42: Node NtpClientUpdateConfiguration (1) Ø In the context menu select Call. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 88: Figure 43: Node Ntpclientupdateconfiguration (2)

    Figure 45: Dialog for configuring the NTP client (successful) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 89: Communication

    292 Byte, for connection 8, connection 9 and connection 10 have a fixed size of · 100 Byte. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 90: Connections 1 To 4

    WP08 data status See section Input process data status [} page 101]. 1 byte Padding byte Do not use NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 91 0: WP07 output data not valid. 1-255: WP07 output data valid. 1 byte Padding byte Do not use NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 92 IO-Link Device. Table 54: Output process data, connection 1 and connection 2 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 93: Connections 5 To 7

    WP08 data status See section Input process data status [} page 101]. 1 byte Padding byte Do not use NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 94 IO-Link Device. Table 55: Input process data, connection 5 to connection 7 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 95 WP08. For a description of the data, see manual of the manufacturer of the used IO-Link Device. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 96 WP16. For a description of the data, see manual of the manufacturer of the used IO-Link Device. Table 56: Output process data, connection 5 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 97: Connections 8 To 10

    WP08 data status See section Input process data status [} page 101]. 1 byte Padding byte Do not use NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 98 IO-Link Device. Table 57: Input process data, connection 8 to connection 10 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 99 WP08. For a description of the data, see manual of the manufacturer of the used IO-Link Device. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 100 WP16. For a description of the data, see manual of the manufacturer of the used IO-Link Device. Table 58: Output process data, connection 8 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 101: Input Process Data Status

    0: Input process data is not valid. 1: Input process data is valid. Table 59: Input data status NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 102: Opc Ua

    The following figure shows a section of the information model of the device. Figure 46: OPC UA: Information model of the device NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 103: Device Identification

    Revision/version of the firmware VendorID Variable read Vendor identification Table 61: Identification of the connected IO-Link Devices NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 104: Ntp Client Configuration

    Example of IP address 192.53.103.108 ((192 * 256 + 53) * 256 + 103) * 256 + 108 = 3224725356 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 105: Mqtt Topics

    Example for the gateway identification JSON object:   "macAddress": "01:02:03:04:05:06",   "serialNumber": "12345678",   "productID": "TMP34Z",   "vendorName": "SensorCompany",   "productName": "FlowSensor34",   "hardwareRevision": "V2.34",   "firmwareRevision": "V1.23",   "productInstanceUri": "sensor.tmp.23.com" NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 106 Example for the gateway configuration JSON object:   "ethIpv4":     [       {         "ipConfiguration": "MANUAL",         "ipAddress": "192.168.1.13",         "subnetMask: "255.255.255.0",         "standardGateway": "192.168.1.1"       }     ] NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 107: Master Topics

    For an example, see Port Data Storage. Table 67: Master topics You find examples and details about the transferred JSON objects below. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 108   "hardwareRevision": "3.2.1.444R",   "firmwareRevision": "3.2.1.888R",   "vendorUrl": "http://www.io-link.com/io-link-master",   "manualUrl": "http://www.io-link.com/io-link-master/manual.pdf",   "applicationSpecificTag": "Fallback reader",   "locationTag": "Down under",   "functionTag": "Code reading" NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 109 Example for the port capabilities JSON object:     "maxPowerSupply": {         "value" : 0.3,         "unit" : "A"     },     "portType" : "CLASS_A" NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 110     "deviceLowPower" : false,     "maxPdSegmentLength" : 2,     "uniqueId" : [11, 12, 13, 14, 15, 16, 17, 18],     "deviceAlias" : "Distance_sensor_1" NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 111 Example for the port data storage JSON object:     "header": {         "vendorId" : 15,         "deviceId" : 65253,         "iolinkRevision" : "1.1"     },     "content": "YmFzZTY0IGVuY3J5cHRlZCBjb250ZW50" NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 112: Device Topics

    [SUBINDEX] set to zero. {prefix}/iolink/v1/devices/[DEVICE_ALIAS]/parameters/ [INDEX]/subindices/[SUBINDEX]/value Table 72: Device topics You find examples and details about the transferred JSON objects below. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 113     "applicationSpecificTag" : "Fallback light switch at the end of the belt",     "locationTag" : "Down under",     "functionTag" : "Check end of belt" NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 114     "setData" : {         "iolink" : {             "valid" : true,             "value" : [128,221,134]         },         "iqValue" : false     } NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 115             "code" : 16912,             "mode" : "APPEARS",             "text" : "Device temperature over-run - Clear source of heat"         }     } NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 116: Mqtt Topics

    Example for the MQTT connection status JSON object: {      "connectionStatus" : "CONNECTION_ACCEPTED",     "serverAddress" : "192.168.2.1./mqttserver",     "upTime" : 123 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 117: Diagnosis

    · 4 Hz: 1 x yellow "On" for 125 ms and 1 x green "On" for 125 ms. Table 77: Definitions of the states of the SYS LED NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 118: Apl Led

    2L supply voltage ok (green) No 2L supply voltage (gray) Table 79: Supply voltage status 1L and 2L NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 119: Ethernet/Ip Adapter Status

    Not powered, no IP address: The device does not have an (off) IP address (or is powered off). Table 80: Communication status EtherNet/IP Adapter NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 120: Table 82: Ethernet Status Ethernet/Ip Adapter

    "Off" for 50 ms. The LED turns on and off in irregular intervals to indicate low Ethernet activity. Table 83: Definition LED states Ethernet status NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 121: Wireless Track Status

    Port inactive (gray) Table 85: Wireless track status WP01 … WP16 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 122: Diagnosis Via Ethernet/Ip

    0: Does not exist 1: Stopped 2: Empty 3: Available 4: Full/Override 5: Full/Stopped 6 – 255: Reserved NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 123: Table 89: Structure Of A Log Entry

    Structure of a log entry Description USINT IO-Link Event Qualifier, always available. UINT IO-Link Event Code, always available. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 124: Cip Status

    13 (0x0D) Object exists already It has been tried to create an instance of an existing object. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 125 A Vendor-specific error has occurred. This Vendor-specific error occurs if none of the general error codes can be used. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 126 Reserved for object class and service errors – 255 An object-class-specific error has occurred. (0xFF) Table 91: Error codes (CIP status) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 127: Diagnosis Over Io-Link

    This error indicates that the IOLW connection failed. Possibly this leads to "Communication loss" 0xFF22. Table 93: IO-Link Wireless Master Event Codes NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 128: Io-Link Device Event Codes (Common)

    Device 0xFF91 Internal Data Storage upload request Notification (single See manual of the used IO-Link shot) Device NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 129 Any other code Reserved See manual of the used IO-Link Device Table 94: IO-Link Device Event Codes (common) NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 130: Technical Data Device

    16 A for 1L and 2L. Observe derating for the maximum current depending on the ambient temperature. Revers polarity protection NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 131: Table 96: Technical Data Sma Antenna

    Polarization Vertical Radiation Omni Mechanical Connector Regular SMA-Male specifications Height 25.6 mm Table 96: Technical data SMA antenna NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 132: Technical Data Io-Link Wireless Master

    Max. 3 masters within a circle of 20 m diameter Antennas 3 SMA antennas Table 97: Technical data IO-Link Wireless Master NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 133: Technical Data Protocol

    Data transport layer Ethernet II, IEEE 802.3 Interface type 10BASE-T, 100BASE-TX, isolated Table 98: Technical data EtherNet/IP Adapter NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 134: Technical Data Netfield Wireless Web Server

    1883 (default), MQTT unencrypted MQTT standard V3.1.1 Restriction The Subscribe service is not supported. Table 101: Technical data MQTT Client NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 135: Dimensions

    13.1 Dimensions netFIELD IO-Link Wireless Master device Figure 48: Dimensions NFD-3090-EIS-IOLM\W device Tolerance The overall tolerance of the dimensions is ± 0.2 mm. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 136: Approvals

    FCC Warning Hilscher Gesellschaft für Systemautomation mbH has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment.
  • Page 137 (RF) ISED règles d'exposition. L'émetteur ne doit pas être colocalisé ni fonctionner conjointement avec à autre antenne ou autre émetteur. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 138: Appendix

    Part 1: Safety requirements, (IEC 62368-1:2014, modified + Cor.:2015); English version EN 62368-1:2014 + AC:2015, English, 2016-05. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 139: Conventions In This Document

    Indicates a hazardous situation, which if not avoided, may result in minor or moderate Injury. Indicates a property damage message. Table 103: Signal words NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 140: Directives And Standards

    2020+A11:2020 - Part 1: Safety requirements Table 104: Directives and standards netFIELD IO-Link Wireless Master device NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 141: Legal Notes

    The manual delivered with the product shall apply. Under no circumstances shall Hilscher Gesellschaft für Systemautomation mbH be liable for direct, indirect, ancillary or subsequent damage, or for any loss of income, which may arise after use of the information contained herein.
  • Page 142 Appendix 142/154 Liability disclaimer The hardware and/or software was created and tested by Hilscher Gesellschaft für Systemautomation mbH with utmost care and is made available as is. No warranty can be assumed for the performance or flawlessness of the hardware and/or software under all application conditions and scenarios and the work results achieved by the user when using the hardware and/or software.
  • Page 143 Additional guarantees Although the hardware and software was developed and tested in-depth with greatest care, Hilscher Gesellschaft für Systemautomation mbH shall not assume any guarantee for the suitability thereof for any purpose that was not confirmed in writing. No guarantee can be granted whereby the...
  • Page 144 The customer hereby expressly acknowledges that this document contains trade secrets, information protected by copyright and other patent and ownership privileges as well as any related rights of Hilscher Gesellschaft für Systemautomation mbH. The customer agrees to treat as confidential all of the information made available to customer by Hilscher Gesellschaft für...
  • Page 145: Registered Trademarks

    (company names or trademarks) of the corresponding owner and may be protected under trademark or patent law. NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 146 Figure 39: Information tab, Device information..............80 Figure 40: ISDU tab, read/write IO-Link Device parameters ..........82 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 147 OPC UA: Information model of the device............102 Figure 47: Event Qualifier ...................... 127 Figure 48: Dimensions NFD-3090-EIS-IOLM\W device ............135 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 148 MQTT in port configuration for IO-Link Device, Client Configuration...... Table 40: MQTT in port configuration for IO-Link Device, Connection1 > IP settings .... NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 149 Table 80: Communication status EtherNet/IP Adapter ............119 Table 81: Definition LED states communication status ............120 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 150 Table 103: Signal words ......................139 Table 104: Directives and standards netFIELD IO-Link Wireless Master device ..... 140 NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 151: Glossary

    IP data packet to it. Therefore, IP is not able to guarantee that the IP data packets really arrive at the NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 152 Task-based firmware component integrating the OPC Foundation C netPROXY stack, as well as an additional server layer from Hilscher for the connection to netPROXY. This component is available as a LOM (Linkable Object Module = library, the respective C-language headers and a WAF script).
  • Page 153 SELV Safety Extra Low Voltage Standard Master Interface UUID Universally Unique Identifier NFD-3090-EIS-IOLM\W | Hardware, installation and commissioning © Hilscher 2020 - 2021 DOC200701UM02EN | Revision 2 | English | 2021-08 | Released | Public...
  • Page 154: Contacts

    Fax: +49 (0) 6190 9907-50 E-mail: info@hilscher.com Support Phone: +49 (0) 6190 9907-99 E-mail: de.support@hilscher.com SUBSIDIARIES China Japan Hilscher Systemautomation (Shanghai) Co. Ltd. Hilscher Japan KK 200010 Shanghai Tokyo, 160-0022 Phone: +86 (0) 21-6355-5161 Phone: +81 (0) 3-5362-0521 E-mail: info@hilscher.cn E-mail: info@hilscher.jp...

This manual is also suitable for:

Nfd-3090-ecs-iolm/w1912.1121912.122

Table of Contents