Fantini Cosmi CH193VMC Instructions For Use Manual

Fantini Cosmi CH193VMC Instructions For Use Manual

Centralised control for vmc units
Hide thumbs Also See for CH193VMC:
Table of Contents

Advertisement

Quick Links

INSTRUCTIONS FOR USE
CH193VMC
CENTRALISED CONTROL
FOR VMC UNITS
Code: AP 20048
AP 20050
AP 20052
AP 20054
AP 20056
AP 20058
FANTINI COSMI S.p.A.
Via dell'Osio, 6 20049 Caleppio di Settala, Milan – ITALY
Tel. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it
www.fantinicosmi.it

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CH193VMC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fantini Cosmi CH193VMC

  • Page 1 FOR VMC UNITS Code: AP 20048 AP 20050 AP 20052 AP 20054 AP 20056 AP 20058 FANTINI COSMI S.p.A. Via dell’Osio, 6 20049 Caleppio di Settala, Milan – ITALY Tel. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it www.fantinicosmi.it...
  • Page 2: Operation

    FANTINI COSMI S.p.A. website: pdf.fantinicosmi.it OPERATION CH193VMC is an LCD remote panel for the advanced control of ventilation systems through VMC. Equipped with temperature, relative humidity and VOC sensors, it automatically controls ventilation and indoor air quality (IAQ). Note: The CH193VMC has been designed to work with different machines.
  • Page 3: Description Of Display Keys

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS DESCRIPTION OF DISPLAY KEYS The first time any touch key is pressed, this activates the functions of the buttons themselves and lights up the display. Day of the week Heating/cooling coil activation state (if the VMC is set up for this)
  • Page 4: Technical Features

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS TECHNICAL FEATURES Rated power supply voltage 9 - 24 Vcc Absorbed current 150 mA Max Backlight switch-off 60s after last touch Temperature regulation scale 5 ÷ 35 °C, increase 0.1°C Measurement scale room T - 50 to + 50 °C, resolution 0.1°C...
  • Page 5: Table Of Contents

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS Contents OPERATION ..............2 6.9 - RH (RELATIVE HUMIDITY PROBE DISPLAY) ......22 6.10 - IAQ (AIR QUALITY PROBE DISPLAY) .........23 CONTENTS OF PACKAGE ..........2 6.11 - DEW P (DISPLAY OF THE DEW POINT) ......23 DESCRIPTION OF DISPLAY KEYS ........
  • Page 6: Installation

    Installation operations must be performed with the system’s power disconnected. CH193VMC must be installed on the wall or on a flush mounting box, in 3 units, at a height of about 1.5m from the floor, in a suitable position to detect the room temperature correctly.
  • Page 7 CH193VMC CENTRALISED CONTROL FOR VMC UNITS Place the rear body in the wall box. Make the electrical connections (refer to “2 - ELECTRICAL CONNECTION”) and secure the rear body to the wall with the screws provided. Hook the front of the control unit onto the rear wall body.
  • Page 8: Electrical Connection

    Electrical connections must be made by qualified personnel. ATTENTION! Electrical connection operations must be done with the system’s power disconnected. CH193VMC is connected directly to the Fantini Cosmi VMC machines. The connection changes based on the VMC code. (Code 1598122) *Note: Jump the terminals.
  • Page 9: Vmc Side Connection

    It is necessary to set from “Advanced User" the EXT IN input to DH/IN. Dehumidification request relay Integration request relay heating / cooling 2.3 - START-UP At first switch-on, the CH193VMC must be coupled to a VMC. Choose the code of the installed VMC. VMC SELECT PRESS ENTER AP20048 AP20050 AP20052...
  • Page 10: User Functions (Prog)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 3 - USER FUNCTIONS (PROG) The first time any touch key is pressed has no effect, but only activates the functions of the buttons themselves and lights up the display. After 60 seconds of no interaction, the display goes back to the main screen.
  • Page 11: Winter/Summer Setting

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 3.2 - WINTER/SUMMER SETTING 15:25 15-09-20 23.0 PROG TEMP DISP USER PROGR DATE AND TIME WINTER PRESS PRESS DATE AND TIME ENTER WINTER WINTER SUMMER VMC PROFILE ENTER TEMP: AUTO PROG DISP: VMC LOCK NO 3.3 - PROGRAMMING SETTING VMC PROFILE...
  • Page 12: Setting Machine Operation In Integration

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS Pressing allows you to select the VMC profile depending on the time. SETTABLE SPEEDS: ■ OFF ■ 1 = V1 ENTER COPY ■ 2 = V2 ■ 3 = V3 ■ Pressing ENTER to go to the next day.
  • Page 13 CH193VMC CENTRALISED CONTROL FOR VMC UNITS PRESS 18.0 ENTER COPY Note: pressing allows you to scroll through the hours. Pressing allows you to select the profile depending on the time. SETTABLE PROFILES: ■ tC (comfort) = SUMMER, WINTER 18.0 ■ tE (economy) = SUMMER, WINTER ■...
  • Page 14: Vmc Panel Display Settings

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 3.5 - VMC PANEL DISPLAY SETTINGS 15:25 15-09-20 23.0 TEMP PROG DISP USER PROGR DATE AND TIME DISP: VMC PRESS PRESS DATE AND TIME DISP:VMC ENTER DISP:TIME WINTER DISP:DEW P VMC PROFILE ENTER DISP:IAQ...
  • Page 15: Setting Keyboard Lock With Password

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS ■ DISP:INTEG = the time schedule of the integration is displayed. 18.0 TEMP PROG DISP 3.6 - SETTING KEYBOARD LOCK WITH PASSWORD 15:25 15-09-20 23.0 TEMP PROG DISP USER PROGR DATE AND TIME LOCK NO...
  • Page 16: Operating Programs (Sel)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 4 - OPERATING PROGRAMS (SEL) For the management of ventilation systems, CH193VMC allows different operating modes, called programmes. [ MAN ] 15:25 15-09-20 ■ MANUAL PROGRAM 23.0 The device adjusts the speed (V1, V2, V3, BOOST, the latter for a limited time) specified from time to time for an unlimited time, until a new command is given.
  • Page 17: Selecting The Operating Program

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 4.1 - SELECTING THE OPERATING PROGRAM The ventilation programmes of the VMC are selected in cycles. 15:25 15-09-20 23.0 PROG TEMP DISP 15:25 15-09-20 15:25 15-09-20 15:25 15-09-20 23.0 23.0 23.0 PRESS [ AUTO ]...
  • Page 18: Operation (Temp)

    TMAN = 20.0° PRESS 24.4 ENTER ENTER Note: adjustment does not depend on the room temperature read by the CH193VMC sensor but on the AIR probe inside the VMC (see paragraph “6.5 - AIR (RETURN AIR TEMPERATURE PROBE INSIDE THE VMC)”).
  • Page 19: T Eco / T Comf

    PRESS 24.4 24.4 ENTER ENTER ENTER Note: adjustment does not depend on the room temperature read by the CH193VMC sensor but on the AIR probe inside the VMC (see paragraph “6.5 - AIR (RETURN AIR TEMPERATURE PROBE INSIDE THE VMC)”).
  • Page 20: Parameter Display (Disp)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 6 - PARAMETER DISPLAY (DISP) Pressing the DISP key allows you to display certain parameters set according to the active operating program. 6.1 - DATE AND TIME 15:25 15-09-20 PRESS 23.0 The date and time are displayed.
  • Page 21: Integration (Only Available With The Integration Function Active)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 6.4 - INTEGRATION (ONLY AVAILABLE WITH THE INTEGRATION FUNCTION ACTIVE) 15:25 15-09-20 PRESS 23.0 [ AUTO ] DISP TEMP PROG DISP 15:25 15-09-20 VMC ONLY : ON The operating status of the integration PRESS...
  • Page 22: H4 (Outdoor Air Intake Probe Positioned Inside The Vmc)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 6.7 - H4 (OUTDOOR AIR INTAKE PROBE POSITIONED INSIDE THE VMC) 15:25 15-09-20 PRESS 23.0 [ AUTO ] DISP TEMP PROG DISP 15:25 15-09-20 H4 = --- PRESS PRESS ENTER UP TO ENTER ENTER 6.8 - EXT...
  • Page 23: Iaq (Air Quality Probe Display)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 6.10 - IAQ (AIR QUALITY PROBE DISPLAY) 15:25 15-09-20 The IAQ (Indoor Air Quality) parameter indicates the level of ambient air PRESS 23.0 [ AUTO ] DISP quality detected by the sensor. TEMP PROG...
  • Page 24: Hours Of Use

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 6.12 - HOURS OF USE The control records the total consumption of the hours the VMC system is switched on. 15:25 15-09-20 PRESS 23.0 [ AUTO ] DISP TEMP PROG DISP 15:25 15-09-20 HOURS OF USE PREV.
  • Page 25: Advanced Functions (Prog)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7 - ADVANCED FUNCTIONS (PROG) To access ADVANCED PROGRAMMING, hold down the PROG key for a few seconds. 7.1 - SWITCHING ON DISPLAY Allows you to adjust the display’s backlight (sky blue light) with a duration that can be programmed between 5 and 30 seconds or always on.
  • Page 26: Daylight Saving / Standard Time

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.3 - DAYLIGHT SAVING / STANDARD TIME Automatically selects daylight saving time, applicable in Europe and some other countries. This set-up automatically updates the time when it changes (March and October) (default = YES).
  • Page 27: Ventilation

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.5 - VENTILATION Allows the speeds of the VMC to be set according to the air flow rates defined in the design phase. Each speed can be set from 0 to 100% of the fan according to the logics defined in the following points.
  • Page 28: Boost = 50

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.5.2 - V3 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S VENTILAT PRESS PRESS PROG UP TO ENTER PROG V1 = 50% V3 = 50% Note: V3 can be set between the...
  • Page 29: Int

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.5.4 - INT Can only be set if the Integration function is active. 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S VENTILAT PRESS PRESS PROG UP TO ENTER...
  • Page 30: Integration (This Function Is Only Visible When Ext Heat Is Active)

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.6 - INTEGRATION (THIS FUNCTION IS ONLY VISIBLE WHEN EXT HEAT IS ACTIVE) 15:25 15-09-20 23.0 This function is activated when heating and/or cooling integration is desired. [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S INTEGR.
  • Page 31: Maximum Temperature

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.6.2 - MAXIMUM TEMPERATURE 15:25 15-09-20 Defines the maximum value of the set point operating range that can be set 23.0 between 5 and 35°C. [ AUTO ] T MIN < T MAX PROG...
  • Page 32: Antifreeze Temperature

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.6.4 - ANTIFREEZE TEMPERATURE 15:25 15-09-20 Note: 23.0 [ AUTO ] ■ the tA that can be set is between 5.0 and 7.0°C or OFF. TEMP PROG DISP ADV. PROGR LIGHT ON 15S INTEGR.
  • Page 33: Celsius / Fahrenheit

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.8 - CELSIUS / FAHRENHEIT This allows you to choose the temperature display scale between Celsius and Fahrenheit degrees (default = CELSIUS). 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S CELSIUS 26.0...
  • Page 34: Sens

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.10 - SENS 15:25 15-09-20 The CH193VMC modulates the ventilation (air flow rate) of the HVAC 23.0 according to the values detected by the relative humidity (RH) and room [ AUTO ] quality (VOC) sensors on the device.
  • Page 35: Voc

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.10.2 - VOC 15:25 15-09-20 If the air quality in the room exceeds the set point values, the VMC 23.0 [ AUTO ] automatically increases ventilation to re-establish optimum air quality. TEMP PROG DISP ADV.
  • Page 36: Filt

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.11 - FILT Allows you to set a parameter (in hours) for changing filters. 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S FILT = --- PRESS PRESS 5000H...
  • Page 37: Alarms

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.13 - ALARMS 15:25 15-09-20 The VMC has a self-diagnostic function that can detect up to 16 different types of faults. The details of the faults are shown in the tables below, 23.0 [ AUTO ] where the presence of the figure "1"...
  • Page 38: Chg

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.15 - EXT IN Allows you to set the input to be used on the system. 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S EXT IN: --- PRESS...
  • Page 39: Sound Alarm

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.16 - SOUND ALARM Allows for an audible alarm in case of anomalies. 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S ALR SND NO PRESS PRESS ENTER ALR SND YES...
  • Page 40: Led

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.18 - LED Allows the LED on the front of the CH193VMC panel to flash. 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP ADV. PROGR LIGHT ON 15S LED YES PRESS PRESS ENTER...
  • Page 41: Resetting Default Parameters

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 7.20 - RESETTING DEFAULT PARAMETERS This allows you to reset all the parameters (except date and time) to the factory settings. 15:25 15-09-20 23.0 [ AUTO ] TEMP PROG DISP RESET NO ADV. PROGR...
  • Page 42: Disposal

    CH193VMC CENTRALISED CONTROL FOR VMC UNITS 8 - DISPOSAL The symbol of the crossed-out wheeled bin indicates that the products must be collected and disposed of separately from household waste. The batteries and integrated accumulators may be disposed of together with the product.
  • Page 43 CH193VMC CENTRALISED CONTROL FOR VMC UNITS...
  • Page 44 FANTINI COSMI S.p.A. Via dell’Osio, 6 20049 Caleppio di Settala, Milan – ITALY Tel. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it www.fantinicosmi.it...

This manual is also suitable for:

Ap 20048Ap 20050Ap 20052Ap 20054Ap 20056Ap 20058

Table of Contents