A  visual  inspection  of  this  product  for  possible  damage  occurred  during  shipment  is
recommended before installation. It is your responsibility to ensure that qualified mechanical
and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power off
the system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch and
fuse as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to
prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble with
the unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may results
in malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During putting equipment in hole on the metal panel while mechanical installation some metal
burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the
montage of the device with inappropriate fixing clamp. Be sure that device will not fall while
doing the montage.
It is your responsibility if this equipment is used in a manner not specified in this instruction
manual.
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts
from the delivery date. This warranty is in force if duty and responsibilities which are
determined in warranty document and instruction manual performs by the customer
completely.
Repairs  should  only  be  performed  by  trained  and  specialized  personnel.  Cut  power  to  the
device before accessing internal parts.
Do not clean the case with hydrocarbon­based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in
ethyl alcohol or water to clean the external plastic case.
:
Emko Elektronik A.S. DOSAB Karanfil Sk.No:6 16369 BURSA/TURKEY
Phone:+90 224 261 19 00
Fax :+90 224 261 19 12
Emko Elektronik Sanayi ve Ticaret A.ª.
Demirtaº Organize Sanayi Bölgesi Karanfil Sk.No:6 16369 BURSA/TURKEY
Phone:+90 224 261 19 00
Fax :+90 224 261 19 12
uvádí:
EMKO EDA3700
3
 Eshop:
www.emareg.cz
 0 to 50 °C
 %90 Rh (Yoğunlaşma olmaksızın)
 Up to 2000 m.
V
±
±
V
±
V
Z
EDA­3700
AC DC
Email:
shop@emareg.cz
2
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EDA-3700 and is the answer not in the manual?

Questions and answers

Summary of Contents for EMKO EDA-3700

  • Page 1 EMKO EDA3700 Automatizace a ovládání / Proudová a výkonová relé  0 to 50 °C  %90 Rh (Yoğunlaşma olmaksızın)  Up to 2000 m. ± ± ± A  visual  inspection  of  this  product  for  possible  damage  occurred  during  shipment  is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product. If there is danger of serious accident resulting from a failure or defect in this unit, power off the system and separate the electrical connection of the device from the system. The unit is normally supplied without a power supply switch or a fuse. Use power switch and fuse as required. Be sure to use the rated power supply voltage to protect the unit against damage and to prevent failure. Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented.
  • Page 2 1­Before mounting the device in your panel, 3­ Insert the mounting clamps to the fixing sockets make sure that the cut­out is of the right size. that located left and right sides of device and make the unit completely immobile within the panel 2­Insert the device through the cut­out. If the mounting clamps are on the unit, put out them before inserting the unit to the panel. Must be determined in order. 1­Pull mounting clamps from left and right fixing Note­1: External fuse is recommended. sockets. 2­Pull the unit through the front side of the panel 230VV(  ±  %15)  50/60Hz 115VV( ± %15) 50/60Hz 24VV   (±%15)50/60Hz 24VW  (±%15)50/60Hz Must be determined in order. Decimal Point Position is determined by this parameter. It can be adjusted from 0 to 3. No point “0” Between first and second digits “0.0” AC DC Between first and second digits “0.00” Between first and second digits “0.000” Sampling time is set with this parameter. It can be adjusted from 0 to 3. Sampling time : 250ms Sampling time : 500ms ** It is used to increase the value in the Programming mode. Sampling time : 750ms Sampling time: 1sn ** It is used to decrease the value in the Programming mode. It can be adjusted between minimum and maximum scale that is specified with ** To access the programming screen; in the main operation screen, press this button for 5 parameter. This parameter can't be lower than seconds.
  • Page 3 Low Limit Alarm On Delay Time Parameter Low Limit Alarm On Delay Time Parameter AC/DC(rms) Alarm Set Value Low Limit Parameter Alarm Set Value Up Limit Parameter 0.000 Input 3T/2 cUH - HSU cUL + HSL 0.000 3T/2 3T/2 0.000 3T/2 0.308A π 3T/2 0.386A π 3T/2 When the  AC / DC ammeter is energized, firstly the revision number of the software is displayed to EDA­3700 EDA­3700 the user. EDA­3700 AC DC Note1: If programming When PROG button is pressed for 5 Press ENTER button for seconds, “P” led starts to blink. If mode accessing password accessing to the programming mode entering is 0, Current conversion password entering '' rU " Revision letter...
  • Page 4 20mΩ code blanks according to your needs. 1K2Ω Please contact us, if your needs are out of the standards. : ON / OFF   :  8A@250V Vfor  Resistive  load    (Alarm  output) Before commissioning the device, parameters must be set in accordance with desired use. (Electrical life : 100.000 switching at full load) Incomplete or incorrect configurations can cause dangerous situations.   : 14 mm Red 4 digits LED Display   : AC(Red), DC(Red),Alarm (Red),Program(Green)   Vdc or Vac can be applied Thank you very much for your preference to use Emko Elektronik products, please visit our Your Technology Partner web page to download detailed user manual. www.emkoelektronik.com.tr Ing. Petr Kotas Rakovecká 809, 73543 Albrechtice tel: 777884900 Eshop: www.emareg.cz shop@emareg.cz...