Hitachi ED-X10 Service Manual page 30

Table of Contents

Advertisement

6-13 HIDDEN SERVICE MENU
HIDDEN SERVICE
AIR-SENSOR
EXECUTE
LAMP ALARM
NOTE
LENS TYPE
1
STARTUP TYPE
1
SOFT RESET
SOFT RESET
If this is executed, all of the user data is initialized.Never use it when not required.
6-14 RUN TIME window
Set operating time display method (accumulated lamp time display method)
1. Select "OPTION" from the Advanced menu, then place the cursor on the "LAMP TIME".
2. Press the [ ], [ENTER] or [RESET] button.
3. Press the [Reset] button once, then press [KEYSTONE] button of the remote control for 3 seconds or
more to display the screen shown below. (The menu will close after 10 seconds if there are no further
operations.)
4. Use [ ] or [ ] to select the usage status number. (The usage status is as shown below.)
Usage status number
All manuals and user guides at all-guides.com
ED-X10/ED-X12(CC9XM2)
To display the OSD for "HIDDEN SERVICE MENU" set up.
By the control panel
1. Display the Advanced menu by
the "MENU" button.(If EASY
MENU appears, choose "Go to
Advanced menu" to display
ADVANCED MENU.)
2. Select the "OPTION" on the
menu.
3. Continue press the button [ ]
fi rst, then press the button [ ]
together with "INPUT", and hold
for 3 seconds.
RUN TIME
LAMP
1234h
BRIGHT
1000
NORMAL
AC
2000
On
Off
No.0
0 ..... Total usage status
1 ..... Current usage status
2 ..... Usage status before first reset
3 ..... Usage status before second reset
||
9 ..... Usage status before eighth reset
30
By the remote control transmitter
1. Display the menu by the
"MENU" button. (If EASY
MENU appears, choose "Go to
Advanced menu" to display
ADVANCED MENU.)
2. Select the "OPTION" on the menu.
3. Press the "MAGNIFY OFF"
button.
Next hold the "MAGNIFY OFF"
button for 3 seconds.
Lamp time
h
Lamp time(BRIGHT)
234
h
Lamp time(NORMAL)
h
AC energizing time
1
Number of times on
0
Number of times off
Usage status number(See below)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ed-x12Cc9xm2

Table of Contents