Download Print this page

Leds; Connect Power - ADTRAN 621i XGS-PON ONT Quick Start

Sdx, 1ge sfu ont

Advertisement

5. Install two screws (included) into the anchor heads. Leave
approximately 1/4 inch (6 mm) protruding from the mounting
surface.
6. Slide the 621i ONT over the screws and exert a small
amount of downward pressure to ensure that the top of the
slots are resting on the shafts of the screws.
g
NOTE
Alternately, wall anchors are not needed if mounting directly to
wall studs.
Step 2: Connect Ethernet
Refer to
Figure 2
and insert a Category 5E (or better) RJ-45 cable
into the port labeled
until there is an audible "click".
GE
Step 3: Connect Fiber
f
CAUTION!
To prevent breaking the fiber, do not exceed the fiber bend radius
of 3.5 in (8.9 cm).
C
CAUTION!
LASER RADIATION - 1310 nm to 1600 nm
Do not view directly with optical instruments.
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
radiation exposure.
Fiber is installed in an SC/APC connector (
the rear of the 621i ONT (see
steps to install fiber.
1. Remove the Dust Cover from the SC/APC Connector.
2. Clean the end of the Incoming Fiber Connector.
3. Before installing the fiber, use an optical power meter to
measure the dB power. The level should not exceed –8 dB.
Use an appropriate bi-directional optical attenuator if the
power levels are at or above –8 dB. A level between –12 and
–18 dBm is acceptable.
4. Connect the Incoming Fiber Connector.
Step 4: Connect Power
To connect power to the 621i ONT, complete the following steps:
1. Plug the supplied 12 V AC/DC Power Adapter into the
connection on the rear of the 621i ONT.
2. Connect the Power Adapter to a standard 100 - 240 V AC
outlet.
3. Verify power is on by checking the power LED on the 621i
ONT. The LED should be green, indicating local power is on.
g
NOTE
ADTRAN recommends only using the DC power adapter that is
provided with the unit.
61287844F1-13A
) located on
OPTICAL
Figure
2). Complete the following
f
CAUTION!
For United States and Canadian applications, the DC Power
Adapter must be an NRTL Listed LPS power supply. For
International applications, the DC Power Adapter must be an LPS
power supply specifically approved for that country.
LED
S
When the 621i ONT first powers up it performs self-tests. Once
the power up self-tests are complete, the status LEDs will reflect
the state of the hardware. The table below details the status
indicated by the LEDs.
LED
Status
Power
2
Optical
2
2
LAN
  
  
2
Alarm/
Update
2
12V
Indication
Off
Power is unavailable
Green
Power is on, self-test passed,
normal operation
Green Flashing
Unit is powering up
Off
Power is available
Green
ONU ranged and authenticated,
is not configured to a service
Green Flashing
ONU is ranging and
(Fast)
synchronization process in
progress
Green Flashing
ONU is ranging and
(Slow)
synchronization process is
complete, is configured with
any triple play service
Red
No fiber connected or Link
failure (LOF/LOS)
Off
No Ethernet connectivity
Green
Ethernet connectivity detected,
no activity
Green Flashing
Activity from Ethernet interface
Off
No alarm detected, no ongoing
software update
Green
ONU software download
complete
Green Flashing
ONU software download
started/ ongoing
Red
ONU software not operational/
ONU failure