Adjustment Instructions - LG DT-42PY10X Service Manual

Chassis : af-046a
Hide thumbs Also See for DT-42PY10X:
Table of Contents

Advertisement

1. Application Object
These instructions are applied to all of the PDP TV, AF-046A.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test equipment.
(2) Adjustments must be done in the correct order.
(3) The adjustments must be performed in the circumstance of
25±5°C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver be must kept 220V, 60Hz
when adjusting.
(5) The receiver must be operational for about 15 minutes
prior to the adjustments.
O
After receiving 100% white pattern, the receiver must be
operate prior to adjustment.(Or white condition in HEAT-
RUN mode)
O
Enter into HEAT-RUN MODE
- Press the POWER ON KEY on R/C for adjustment.
OSD display and screen display 100% full WHITE
PATTERN.
[ Set is activated HEAT-RUN without signal generator in
this mode.
If you turn on a still screen more than 20 minutes (Especially
Digital pattern(13 CH), Cross Hatch Pattern), an afterimage
may occur in the black level part of the screen.
3. EPLD Download
PC
<Fig 1> Connection Diagram of EPLD Download
(1) Test Equipment: PC, Jig for download
(2) Connect the power of VSC B/D.
(3) Execute download program of PC.
(4) After executing the hot key on the Programmer, click icon
(5) End after confirming.
All manuals and user guides at all-guides.com

ADJUSTMENT INSTRUCTIONS

VSC
B/D
- 14 -
Each PCB Assy must be checked by Check JIG Set before
assembly. (Especially, be careful Power PCB Assy which can
cause Damage to the PDP Module.)
4. POWER PCB Assy Voltage
Adjustment
(Va, Vs Voltage Adjustment)
4-1. Test Equipment :
4-2. Connection Diagram for Measuring
Refer to Fig 1.
Va
P806
GND
NC
VS
P805
DMM
Va ADJ
RV601
+
-
P804
P807
P801
P802
P803
Va
P806
GND
NC
VS
P805
DMM
Va ADJ
RV601
+
-
P804
P807
P801
P802
P803
<Fig. 2> Connection Diagram of Power Adjustment for
Measuring (Power Board)
(1) Va Adjustment
1) After receiving 100% Full White Pattern, Heat-Run(over
10min).
2) Connect + terminal of D.M.M to Va pin of P805 and
connect – terminal to GND pin of P805.
3) Adjust RV601 voltage to match that of the label on the
Top/Right of the panel. (Deviation : ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D.M.M to Vs pin of P805 and
connect – terminal to GND pin of P805.
2) Adjust RV401 voltage to match that of the label on the
Top/Right of the panel. (Deviation : ±0.5V)
D.M.M 1EA
Vs ADJ
V401
<3501V00182B>
Vs ADJ
V401
<3501V00188A>

Advertisement

Table of Contents
loading

Table of Contents