Stalgast 880173 User Manual

Stalgast 880173 User Manual

Freezer/cooling cabinet

Advertisement

USER MANUAL
v8.0 - 03.2018
Freezer/cooling cabinet
MODEL:
880173, 880174, 880175, 880176, 880177,
880400, 880401, 880402, 880405, 880406, 880600, 880601,
880602, 880603, 880604
Stalgast sp. z o.o. ul. Staniewicka 5 03-310 Warszawa
tel.: 22 517 15 75 fax: 22 517 15 77 www.stalgast.com email: stalgast@stalgast.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 880173 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stalgast 880173

  • Page 1 Freezer/cooling cabinet MODEL: 880173, 880174, 880175, 880176, 880177, 880400, 880401, 880402, 880405, 880406, 880600, 880601, 880602, 880603, 880604 Stalgast sp. z o.o. ul. Staniewicka 5 03-310 Warszawa tel.: 22 517 15 75 fax: 22 517 15 77 www.stalgast.com email: stalgast@stalgast.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. SAFETY INSTRUCTIONS ....................... 3 2. PURPOSE OF THE DEVICE ....................3 3. TECHNICAL DATA ........................3 4. ASSEMBLY ..........................3 4.1. Device setting ..............................3 4.2. Connection to the power supply source ......................4 5. CONTROL PANEL OPTION 1 ....................4 5.1.
  • Page 3: Safety Instructions

    • Never pull the device by the power cord. 2. PURPOSE OF THE DEVICE • Refrigeration tables are designed for short-term storage of pre-chilled CHILLED food products. • Freezer tables are designed for storage of pre-frozen food products. 3. TECHNICAL DATA Model 880173, 880174, 880177 880400, 880402 880401,...
  • Page 4: Connection To The Power Supply Source

    If the device is installed in a room with high humidity, you may need to buy an additional tray for condensed water. Avoid placing the device in rooms with a high chlorine content and acids in the air (e.g. swimming pools), as this may cause corrosion of the stainless steel surface.
  • Page 5: Description Of The Parameters

    5.3. Description of the parameters Code Function Setup Range Default value Unit 00-99 Menu password NONE 00: canceling the button lock function Setting the temperature value -40 ~+50 °C Setting the temperature 1 – 15 °C difference Delay of compressor 1 –...
  • Page 6: Control Of Compressor Operation And Defrost Function

    Press the button „ ”and hold for 3 seconds to manually activate or deactivate defrosting. 5.5. Control of compressor operation and defrost function • Compressor: The compressor will be activated when the time of its activation delay has elapsed if the temperature sensor shows that it is higher than the „set temperature value + value of the temperature difference”.
  • Page 7: Description Of Indicator

    6.1. Description of indicator compressor activated Flashes the programming phase has been started defrosting activated Flashes Programming phase, dripping Degrees Fahrenheit Degrees Celsius 6.2. How to check the duration of the alarm and the minimum and maximum temperatures If the alarm symbol appears in the display; to view the type of alarm, min (max) temperature, alarm duration, proceed as follows.
  • Page 8: Continuous Cycle

    6.10. Continuous cycle If the defrosting process is not activated, the continuous process can be activated by pressing and holding the up arrow button for 3 seconds. The compressor will run in continuous mode until the Cct parameter is reached. This process can be interrupted before its end by holding the up arrow for 3 seconds.